Water Total Organic Carbon Test Machine Total Inorganic Carbon Test Equipment NPOC Measurement Machine

Product Specifications Select Now
model number
LS-TA-200
Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (9)
  • Water Total Organic Carbon Test Machine Total Inorganic Carbon Test Equipment NPOC Measurement Machine
  • Water Total Organic Carbon Test Machine Total Inorganic Carbon Test Equipment NPOC Measurement Machine
  • Water Total Organic Carbon Test Machine Total Inorganic Carbon Test Equipment NPOC Measurement Machine
  • Water Total Organic Carbon Test Machine Total Inorganic Carbon Test Equipment NPOC Measurement Machine
  • Water Total Organic Carbon Test Machine Total Inorganic Carbon Test Equipment NPOC Measurement Machine
  • Water Total Organic Carbon Test Machine Total Inorganic Carbon Test Equipment NPOC Measurement Machine
Find Similar Products
  • Overview
  • Company Information
Overview

Basic Info.

Model NO.
LS-TA-200
Max Diameter of Workpiece
<500mm
Mass Scope of Workpiece
900kg
Type
Testing Machine
Maxcapacity
<1000KN
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
100-500Kg
Power Source
AC220V
Oil Cylinder Position
Top
brand name
LANGSHUO
Power Supply
220 V
place of origin
Hunan, China
Model
LS-TA-200
Transport Package
/
Specification
/
Trademark
LANGSHUO
Origin
Hunan, China
HS Code
9024800000
Production Capacity
200

Product Description

Water Total Organic Carbon Test Machine Total Inorganic Carbon Test Equipment NPOC Measurement Machine

Application Scope

Widely used for the determination of total carbon (TC), total organic carbon (TOC), total inorganic carbon (TIC), non-purgeable total organic carbon (NPOC) and other parameters in surface water, groundwater, industrial water, domestic sewage, production wastewater, seawater, drinking water and its source water.
 

Instrument Features

  1. Adopts 24-bit A/D conversion technology and 32-bit signal processing technology.
  2. Automatic leak detection and control system: monitors gas flow in real time with an alarm function to prevent gas leakage.
  3. Four-in-one technology for TIC reaction cell: heating, cooling, dehydration and liquid level monitoring.
  4. Automatic micro-sampling with controllable sample injection volume.
  5. Supports online parameter setting, real-time monitoring, self-calibration and flow rate control.
  6. Real-time detection software: plots sample curves on the same coordinate for intuitive repeatability display; monitors instrument operation status at all times and compares measured parameters with set parameters.
  7. Micro-signal processing system features online setting, real-time monitoring, self-verification and flow rate control, ensuring superior instrument performance and safe operation.
  8. Automatic leak detection and control system: detects gas flow in real time with alarm settings to prevent gas leakage, maximizing the safety of operators and the instrument.
  9. Application of flow rate control signal processing technology shields the impact of flow fluctuations and ensures stable and accurate readings.
  10. Real-time detection software: draws sample curves under the same coordinate system to visually show repeatability; tracks instrument operating status continuously and compares actual measured parameters with preset values.
  11. Different control temperatures can be set according to the properties of various samples to achieve complete sample digestion and ensure more accurate and reliable measurement data.
  12. The instrument adopts an internal weak-current design for safe operation.

Water Total Organic Carbon Test Machine Total Inorganic Carbon Test Equipment NPOC Measurement Machine

Technical Specifications

 
Item Specification
Model LS-TA-200 (Dry Method)
TOC Measurement Range 0 ~ 30000 mg/L
Maximum Salt Tolerance 85 g/L
TOC Measurement Items IC, TIC, TOC
Detector NDIR (Non-Dispersive Infrared Detector)
Operation Mode Computer-controlled
Application Sample Water samples
Gas Requirement Oxygen: ≥ 99.995%
Detection Limit 50 μg/L
Digestion Principle High-temperature catalytic oxidation
Repeatability 3%
Analysis Time 1-4 minutes per parameter
Digestion Temperature 0-1000 °C (adjustable)
Sample Temperature 1 °C ~ 95 °C
Particle Size ≤ 0.2 mm
Power Supply 220 VAC, 50/60 Hz
Dimensions (LWH) 430 * 455 * 440 mm
 
 
Company Information

Water Total Organic Carbon Test Machine Total Inorganic Carbon Test Equipment NPOC Measurement MachineWater Total Organic Carbon Test Machine Total Inorganic Carbon Test Equipment NPOC Measurement Machine

Water Total Organic Carbon Test Machine Total Inorganic Carbon Test Equipment NPOC Measurement MachineWater Total Organic Carbon Test Machine Total Inorganic Carbon Test Equipment NPOC Measurement Machine

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now