Flame Graphite Furnace Laboratory Integrated Atomic Absorption Spectrometer Atomic Absorption Instrument

Product Specifications Select Now
model number
LS-AAS8516
Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2020-01-13
Number of Employees
6
  • Flame Graphite Furnace Laboratory Integrated Atomic Absorption Spectrometer Atomic Absorption Instrument
  • Flame Graphite Furnace Laboratory Integrated Atomic Absorption Spectrometer Atomic Absorption Instrument
  • Flame Graphite Furnace Laboratory Integrated Atomic Absorption Spectrometer Atomic Absorption Instrument
  • Flame Graphite Furnace Laboratory Integrated Atomic Absorption Spectrometer Atomic Absorption Instrument
  • Flame Graphite Furnace Laboratory Integrated Atomic Absorption Spectrometer Atomic Absorption Instrument
  • Flame Graphite Furnace Laboratory Integrated Atomic Absorption Spectrometer Atomic Absorption Instrument
Find Similar Products
  • Overview
  • Company Information
Overview

Basic Info.

Model NO.
LS-AAS8516
Max Diameter of Workpiece
<500mm
Mass Scope of Workpiece
<900kg
Type
Testing Machine
Maxcapacity
<1000KN
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
/
Protection Class
Ip56
Accuracy
0.1%~0.5%FS
customized
ODMOBMOEM support
brand name
LANGSHUO
Voltage
220V
Accuracy Class
High Accuracy
place of origin
Hunan,China
Application
Lab Testing, Laboratory Testinq
Transport Package
/
Specification
/
Trademark
LANGSHUO
Origin
Hunan, China
HS Code
9024800000
Production Capacity
200

Product Description

Flame Graphite Furnace Laboratory Integrated Atomic Absorption Spectrometer Atomic Absorption Instrument

Description:

The LS-AAS8516 Flame Graphite Furnace Integrated Atomic Absorption Spectrometer is a fully automatic, intelligent flame graphite furnace integrated atomic absorption instrument developed by the company based on years of research and development experience. It is used to determine the content of macro, micro, and trace metal and metalloid elements in various substances. The instrument uses a PC and Chinese interface operating software, making it easy and intuitive to operate. Advanced electronic circuit systems and USB 3.0 communication control enable automatic adjustment of functions such as wavelength scanning, peak finding and positioning, spectral bandwidth, rotating element lamp holder, atomizer height and position, gas flow rate, lamp current, and photomultiplier tube negative high voltage. The instrument stores reference conditions for all measured elements in various analytical methods. Users can modify the operating conditions as needed and save the operating conditions, working curves, and test results for later retrieval and processing.

 

Advantages:

Flame Graphite Furnace Laboratory Integrated Atomic Absorption Spectrometer Atomic Absorption Instrument

 

Flame Graphite Furnace Laboratory Integrated Atomic Absorption Spectrometer Atomic Absorption Instrument

Technical Parameters:

Overall Machine

Monochromator type:

(Czerny-Turner)

Wavelength Range

190nm~900nm

 

Wavelength Accuracy:

±0.25nm

wavelength repeatability:

<0.05nm

 

Spectral bandwidth:

0.1/0.2/0.4/0.7/1.4 nm Five-speed automatic switching

 

Flame system

Accuracy:

<0.8%(Flame method for copper measurement)

 

Detection Limit :

<0.008ug/mL

 

 

Characteristic Concentration:

<0.025μg/ml/1%(Flame method for copper measurement)

Static stability

0.003 Abs(static)

Dynamic stability

0.004 Abs(dynamic)

 

Graphite furnace system

Graphite furnace temperature control range: Room temperature - 3000

Graphite furnace precision for cadmium (Cd) measurement: ≤2% (automatic sampling mode)

Graphite furnace detection limit for cadmium (Cd): ≤1 pg (automatic sampling mode)

Graphite furnace characteristic mass for cadmium (Cd): ≤0.5 pg

Graphite furnace heating rate: 3000/s

Graphite furnace precision for cadmium (Cd) measurement: ≤5% (manual sampling mode)

Graphite furnace detection limit for cadmium (Cd): ≤2 pg (manual sampling mode)

Power supply: 220V±22V, 50Hz±1Hz, 5KW (peak)

 

Company Information

 Flame Graphite Furnace Laboratory Integrated Atomic Absorption Spectrometer Atomic Absorption InstrumentFlame Graphite Furnace Laboratory Integrated Atomic Absorption Spectrometer Atomic Absorption InstrumentFlame Graphite Furnace Laboratory Integrated Atomic Absorption Spectrometer Atomic Absorption InstrumentFlame Graphite Furnace Laboratory Integrated Atomic Absorption Spectrometer Atomic Absorption Instrument


Flame Graphite Furnace Laboratory Integrated Atomic Absorption Spectrometer Atomic Absorption InstrumentFlame Graphite Furnace Laboratory Integrated Atomic Absorption Spectrometer Atomic Absorption Instrument

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now