Programmable Thermal Shock Test Chamber Laboratory Hot And Cold Thermal Shock Test Chamber
Main Functions:
This series of products is suitable for testing various performance indicators and quality management of aerospace products, information and electronic instruments and meters, materials, electrical engineering, vehicles, metals, electronic products, various electronic components, wires, and cables in high and low rapid alternating environments.
Programmable Thermal Shock Test Chamber Laboratory Hot And Cold Thermal Shock Test Chamber
Performance indicators and system components
|
Product Name |
Thermal shock test chamber |
|
Model |
LS-K191 |
|
Sample Limit |
This test equipment is prohibited from testing samples with flammable, explosive, or volatile substances; testing samples with corrosive substances; testing samples with biological substances; testing samples with strong electromagnetic radiation sources; and storing samples with strong electromagnetic radiation sources. |
|
Volume, weight and dimensions |
|
|
Nominal internal volume |
50 L |
|
Effective inner box dimensions |
W350*H400*D400 (mm) |
|
External dimensions |
Approximately W1350*H1720*D1600 (mm) |
|
Weight |
550 kg |
|
Power supply voltage and power |
|
|
Maximum power |
22.5KW |
|
Maximum current |
45A |
|
Power supply conditions and power supply |
AC 380V three-phase R, S, T, N + protective ground Voltage fluctuation range: 10% Frequency fluctuation range: (50 ± 0.5) Hz TN-S or TT power supply Protective ground wire resistance less than 4Ω The user is required to configure an air or power switch of appropriate capacity for the device at the installation site, and this switch must independently control the operation of this device. |
|
Performance indicators |
|
|
Functional requirements |
1. (Air) Cooling and heating indoor spaces; 2. Based on the set temperature, the indoor space reaches the set temperature. 3. Divided into three areas: heat storage area, cold storage area, and test area. 4. The three areas are independent, with temperature control via dampers. |
|
Environmental conditions |
Ambient temperature: 0~+35, relative humidity ≤85% |
|
Meet the test standard test method |
GJB150.5A-2009 Temperature Shock Test GB/2423.13-2002 Temperature Shock Test GJB360B-2009 Temperature Shock Test GB2423.1-2008/IEC6008-2-1-2007 Environmental Testing for Electric and Electronic Products - Part 2: Test Methods - Test A: Low Temperature GBT 2423.2-2008 Environmental Testing for Electric and Electronic Products - Part 2: Test Methods - Test B: High Temperature GBT 10589-2008 Technical Specifications for Low-Temperature Test Chambers GBT 11158-2008 Technical Specifications for High-Temperature Test Chambers |
|
Temperature range |
|
|
Temperature range |
High temperature range: RT to 170°C Low temperature range: RT to -60°C Test temperature range: -40°C to 150°C |
|
Temperature shock range |
High temperature: 60~150 Low temperature: -10~-40 Normal temperature: indoor temperature |
|
Control accuracy |
Resolution accuracy: 0.1°C Temperature fluctuation: ±1°C Distribution uniformity: ±2.0°C Temperature deviation: ±1°C |
|
Heating and cooling rate |
Heat storage area heating time: From room temperature to 170°C, approximately 30 minutes; Cooling area cooling time: From room temperature to -60°C, approximately 50 minutes |
|
Temperature recovery time |
Test area temperature recovery time: 5 minutes. Impact process (as shown in the figure) Green is the heat storage curve in the high temperature area, red is the impact curve in the experimental area, and blue is the cold storage curve in the low temperature area. |
|
Note: The above performance indicators are measured at an ambient temperature of +25°C, relative humidity ≤85%, and without a sample. |
|
|
Structural characteristics |
|
|
Cabinet structure |
Inner box material: 304# stainless steel, 1.0mm thick Outer box material: Cold plate, painted, 1.2mm thick Insulation material: Polyurethane foam + glass fiber, 100mm thick |
|
Door |
Single door explosion-proof handle |
|
Air conditioning duct |
Built-in high temperature zone, low temperature zone air room, circulating air duct and stainless steel circulating fan. Through the switching of the damper, heat and cold are evenly blown out from the inside of the air duct, and the temperature stored in the high temperature tank and low temperature tank is dissipated to the test space, thereby achieving rapid temperature alternation and uniform indoor temperature distribution. |
|
Test lead hole |
A 50mm Φ test hole is drilled and fitted with appropriate insulation components and a dedicated sealing plug. |
|
Control panel |
Taiwan U-Yi LCD touchscreen programmable controller. Main power switch, operation indicator, abnormality indicator, end indicator, defrost indicator, power indicator, and RS-232 communication interface. |
|
Low-temperature mechanical room |
Evaporator, circulating fan, drain, cold storage fins, heater, circulating fan impeller, volute |
|
High-temperature mechanical room |
Heater, circulating fan, hot storage fins, pressure equalization port, circulating fan impeller, volute |
|
Power distribution control cabinet |
Main power circuit breaker, controller, distribution board, cooling fan, over-temperature protector, cylinder, pressure protector, liquid storage tank, water-cooled condenser, and refrigeration unit. |
|
Heating system |
P.I.D.-type heat pipes are used to control heating and achieve temperature balance. |
|
Cooling system |
(Optional) Use domestic high-quality cooling water tower, |
|
Cooling water tower |
Water circulation heat dissipation, flow rate 8 tons/hour |
|
Transportation method |
Complete machine transportation |
|
Test material rack |
2 pieces of stainless steel SUS #304 grid-type storage racks (load-bearing capacity ≤ 20kg/piece) |
|
How it works |
The pre-cooling area, pre-heating area and test area are independent of each other. The three boxes can be switched through the air door without moving the test product. When the room temperature is impacted, the ambient temperature is introduced into the test space through the blower to remove the heat or cold in the test space. At the same time, the air doors of the high and low temperature slots are closed. When the low temperature is impacted, the air doors of the high and normal temperature slots are closed, and the low temperature slot is connected to the test box, and the pre-stored cold energy is instantly introduced into the test box. When the high temperature is impacted, the air doors of the low and normal temperature slots are closed, and the high temperature slot is connected to the test box, and the pre-stored heat is instantly introduced into the test box. Thus, the purpose of rapid temperature alternation is achieved. |
|
Electrical control system |
|
|
Controller |
Taiwan Youyi controller, temperature control |
|
Screen display function |
Adopts a human-machine interactive mode with touch-screen input and control. Directly displays the setpoint (SV) and actual (PV) temperature values. Displays the program number, step, remaining time, number of cycles, and operating time. Displays the program status. Language switchable between Traditional Chinese and English. 7-inch color LCD display |
|
Program capacity and control functions |
Program capacity: Up to 120 sets, with program links. Command re-execution capability: Each command can be executed up to 9999 times. High temperature start/low temperature start/normal temperature start; two-zone or three-zone shock functions. Preheat and precool functions. Skip and hold functions during program execution. Six PID parameter settings. Power-off program memory, automatic restart and continued program execution upon power-on. Temperature wait timer function. Data acquisition, export, and graph viewing functions. Scheduled start and shutdown functions. Date and time adjustment functions. Key and screen lock (LOCK) function. Automatic cycle shock or manual selective shock. Fault history display. Display backlight adjustment and configurable backlight timer. PID automatic calculation and fuzzy control. |
|
RS-232 communication interface |
Can display curves and acquire data Can be used as a monitoring and remote control system |
|
USB flash drive |
Configurable 2-32GB memory card, capable of recording test data for two years (self-provided). |
|
Operation mode |
Program loop mode |
|
Setting range |
Adjustable according to the device's operating temperature range (upper limit +5°C, lower limit -5°C) |
|
Display resolution |
Temperature: 0.1°C; Time: 0.1 min; |
|
Input |
Thermocouple |
|
Circulation fan |
Low-noise multi-blade long-axis motor |
|
Heater |
Imported nickel-chromium alloy electric heater. Heater control method: Contactless equicyclic pulse width modulation, SSR (solid-state relay) |
|
Control method |
Anti-integral windup PID BTC balanced temperature control method (temperature test equipment) |
|
Additional functions (standard configuration) |
Fault alarm, cause, and action prompts Power-off protection Upper and lower temperature limit protection Self-diagnosis and automatic shutdown |
|
Software environment |
IBM PC compatible computer, CPU P or above, memory 128MB or above, Simplified Chinese Windows 2000 or Simplified Chinese Windows XP operating system |
|
Temperature measurement |
T-type thermocouple |
|
Refrigeration system |
|
|
Refrigeration method |
In order to ensure the cooling rate and minimum temperature requirements of the laboratory, this laboratory adopts a binary compound refrigeration system. The compound system includes a high-temperature refrigeration cycle and a low-temperature refrigeration cycle. Heat exchange is achieved through an evaporative condenser. |
|
Refrigeration compressor |
Imported low-temperature compressor - France Taikang 6P*2 units |
|
Cooling method |
1. Air Cooling - Optional for indoor ambient temperature control below 35°C 2. Water Cooling - Optional for indoor ambient temperature control above 35°C Water Cooling: Water-cooled shell and tube condenser, cooling tower heat dissipation |
|
Evaporator |
Fin-tube heat exchanger |
|
Evaporator condenser |
Using high-temperature copper brazing, the plate-type heat exchanger features a small surface area, minimal energy loss, and high heat transfer efficiency. |
|
Throttling device |
Thermostatic expansion valve, capillary tube |
|
Oil separator |
Separate the refrigeration oil droplets mixed with the high-temperature and high-pressure refrigerant gas discharged from the compressor and return them to the compressor curved track cavity for compressor lubrication and cooling |
|
filter drier |
Absorbs residual moisture and acidic substances in the refrigerant of the refrigeration system, and filters out solid impurities, copper shavings, etc. in the system, protecting the normal operation of the expansion valve and capillary tube to avoid ice blockage and dirt blockage. |
|
refrigerant |
Environmentally friendly refrigerant R404A/R23 is used as the refrigeration medium of this refrigeration system |
|
Safety protection device |
|
|
Refrigeration system |
Compressor overheat, compressor overcurrent, compressor overpressure, condenser fan overheat |
|
test chamber |
Adjustable over-temperature protection; Air conditioning duct over-temperature limit; Fan and motor overheat relay |
|
other |
Main power phase sequence and phase loss protection Leakage protection Overload and short circuit protection Ambient temperature overload protection |