• Leakage Marking Tester/Leakage Marking Index Meter
  • Leakage Marking Tester/Leakage Marking Index Meter
  • Leakage Marking Tester/Leakage Marking Index Meter
  • Leakage Marking Tester/Leakage Marking Index Meter
  • Leakage Marking Tester/Leakage Marking Index Meter
  • Leakage Marking Tester/Leakage Marking Index Meter

Leakage Marking Tester/Leakage Marking Index Meter

After-sales Service: Online
Warranty: 1 Year
Type: Leakage Marking Tester
Control: Computer Control
Weight: 0-100Kg
Power Source: AC220V
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
KDYD-LH
Transport Package
Plywood Case
Trademark
LONROY
Origin
China
HS Code
9024800000
Production Capacity
200pieces/Month

Product Description

Leakage Marking Tester/Leakage Marking Index Meter
KDYD-LH high voltage leakage marking tester is suitable for electrical and electronic products, household appliances and their materials for electrical tracing and corrosion resistance test, simulation at power frequency (48Hz-62Hz), with liquid contaminants and inclined samples, Electrical insulation materials used in harsh environmental conditions are evaluated by measuring their resistance to electrical tracing and erosion. Leakage marking test is to apply a set voltage on the surface of a solid insulating material, between two electrodes, and drop a specified concentration of liquid at a certain height to evaluate the leakage marking resistance of the surface of a solid insulating material under electric field and contaminated media. KDYD-LH high voltage leakage marking tester is designed and manufactured in strict accordance with GB/ T6533-2003 and IEC60587-1984. It is suitable for lighting equipment, low-voltage electrical appliances, room electrical appliances, machine tool electrical appliances, insulating materials, engineering plastics, electrical connectors, mainly used to assess the resistance of outdoor insulating materials (thermosetting, thermoplastic molding plastics, laminates, synthetic insulators, cable accessories, etc.) under harsh conditions of electrical marking and corrosion.
 
Product characteristics
1, drop accurate: the use of precision plunger pump as the contaminated liquid supply system, the flow rate is uniform and stable;
2, test voltage stability: high sampling frequency, accurate measurement value, control system with automatic voltage regulation function, not affected by power grid voltage fluctuations, large equipment capacity, low voltage drop under test conditions; 4, safe and reliable: the system has an exhaust system, timely elimination of harmful gases generated by discharge, and has self-locking, door interlocking, zero limit start, upper limit protection, overcurrent, overvoltage and other protection functions.
 
Leakage Marking Tester/Leakage Marking Index Meter
Executive standard
1, is strictly in accordance with GB/ T6533-2003 and IEC60587-1984 design and manufacture.
2, according to GB/T 6533-2014 "Test method for evaluating Electrical insulation materials used in harsh environments for electrical tracing and erosion" (equivalent to IEC 60587-2007), in line with ASTM D2303-2003 and other test methods.
3, JJG 795-2016 "Voltage Tester"
4, GB50150-2016 "Electrical equipment installation engineering electrical equipment handover test Standard"
5, DL/T 596-1996 "Electric Power Equipment preventive test Procedures"
6, GB10941-GB10946-96 "Shell protection level"
7, GB2900 "Electrician terminology"
8, GB/T16927.1~2-1997 "High voltage test Technology"
 
Leakage Marking Tester
Electrode 0.5mm thick material 304 stainless material, upper and lower electrode distance: 50.0mm±0.1
test voltage 100V-6000V stepless adjustable
voltage stability ±1%
voltage regulator output: 0 ~ 250V can be adjusted, capacity 5KVA
test transformer capacity 5KVA, the highest output voltage AC6000V
output voltage: AC
high-precision regulator output AC220V power 6000W, accuracy ±1%
when the high voltage circuit current in the test reaches or exceeds 60mA for 2S, the relay action, cut off the current, the buzzer alarm indicates that the test is unqualified, then the alarm can be lifted by stopping the voltage
marking judgment according to the standard GB/T6553-2003/4.1.2, apply voltage (2.5kV, 3.5kV and 4.5kV) on the sample, and drop the contaminated liquid at a certain flow rate, the current below 60mA lasts 6H, but the flow is passed
test time 6 hours
drop interval time test time can be preset, 0 ~ 99.99S/M/H can be continuously adjustable
drop device high precision drop device, drop device height adjustable, precision peristaltic pump, adjustable flow range
test solution ammonium chloride, isoctylphenoxy polyethoxyethanol, non-ionic wetting agent with distilled water or deionized water mixture. The resistivity of the contaminated liquid at (23 sh)1ºC should be (3.95 sh 0.05)Ω·m.
filter paper size according to the standard size requirements, filter paper thickness of 0.15 ~ 0.17mm.


Leakage Marking Tester/Leakage Marking Index MeterLeakage Marking Tester/Leakage Marking Index MeterLeakage Marking Tester/Leakage Marking Index MeterLeakage Marking Tester/Leakage Marking Index MeterLeakage Marking Tester/Leakage Marking Index Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now