• DMF61010 Damped Shock Wave Field Generator Oscillatory Magnetic Field Immunity Tester IEC61000-4-10
  • DMF61010 Damped Shock Wave Field Generator Oscillatory Magnetic Field Immunity Tester IEC61000-4-10
  • DMF61010 Damped Shock Wave Field Generator Oscillatory Magnetic Field Immunity Tester IEC61000-4-10
  • DMF61010 Damped Shock Wave Field Generator Oscillatory Magnetic Field Immunity Tester IEC61000-4-10
  • DMF61010 Damped Shock Wave Field Generator Oscillatory Magnetic Field Immunity Tester IEC61000-4-10
  • DMF61010 Damped Shock Wave Field Generator Oscillatory Magnetic Field Immunity Tester IEC61000-4-10

DMF61010 Damped Shock Wave Field Generator Oscillatory Magnetic Field Immunity Tester IEC61000-4-10

After-sales Service: Online
Warranty: 1 Year
Maxcapacity: <1000KN
Accuracy Grade: 1
Load Way: Electronic Load
Display: Digital
Samples:
US$ 3000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
DMF61010
Control
Manual Control
Weight
20kg
Power Source
AC220V
Transport Package
Plywood Cases
Specification
48*52*22cm
Trademark
LONROY
Origin
Guangdong
HS Code
9024800000
Production Capacity
200

Product Description

DMF61010 Damped Shock Wave Field Generator Oscillatory Magnetic Field Immunity Tester  IEC61000-4-10
Product Overview:
The damped oscillating wave magnetic field is simulated by the isolation brake and the high voltage busbar, which can test the ability of the equipment to resist the oscillating magnetic field under operating conditions. Products fully meet the requirements of IEC61000-4-10 standards.

DMF61010 Damped Shock Wave Field Generator Oscillatory Magnetic Field Immunity Tester  IEC61000-4-10
Product features:
1.7.0 color touch screen display, built-in temperature and humidity display
2.Meet the requirements of IEC61000-4-10 standard;
3.Chinese and English switch, more convenient use;
4.Programmable operation, to achieve one button to complete the setting function;
5.The use of imported program controlled high voltage power supply, good reliability;
6.Multi-channel output port, easy to operate;
7.Simple to use, do not need to pay attention to the operation sequence (software protection);
8.Built-in RS232/RJ45 interface, easy to upgrade products, optional measurement and control software for remote control;
 
Parameters  DMF61010                                   
satisfying criteria IEC61000-4-10
Oscillator Frequency
100KHz 1MHz
magnetic field intensity 8 A/m~110 A/m 8 A/m~100 A/m
repetition period 20ms~50ms 2ms~50ms
time of duration 0.1s~100s 0.1s~10s
interval time 1s~9999s 5s~9999s
Test number
1~9999C
Overall size/weight 480*520*220mm 20kg
 
 DMF61010 Damped Shock Wave Field Generator Oscillatory Magnetic Field Immunity Tester IEC61000-4-10DMF61010 Damped Shock Wave Field Generator Oscillatory Magnetic Field Immunity Tester IEC61000-4-10