• 0-5000V 0-10000V High Resistance Box/Insulation Resistance Tester Calibration Device/Megohmmeter Detection Device
  • 0-5000V 0-10000V High Resistance Box/Insulation Resistance Tester Calibration Device/Megohmmeter Detection Device
  • 0-5000V 0-10000V High Resistance Box/Insulation Resistance Tester Calibration Device/Megohmmeter Detection Device
  • 0-5000V 0-10000V High Resistance Box/Insulation Resistance Tester Calibration Device/Megohmmeter Detection Device
  • 0-5000V 0-10000V High Resistance Box/Insulation Resistance Tester Calibration Device/Megohmmeter Detection Device
  • 0-5000V 0-10000V High Resistance Box/Insulation Resistance Tester Calibration Device/Megohmmeter Detection Device

0-5000V 0-10000V High Resistance Box/Insulation Resistance Tester Calibration Device/Megohmmeter Detection Device

After-sales Service: Online
Warranty: 1 Year
Type: High Resistance Box
Control: Computer Control
Weight: 0-100Kg
Power Source: AC220V
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
KDZD
Transport Package
Plywood Case
Trademark
LONROY
Origin
China
HS Code
9024800000
Production Capacity
200pieces/Month

Product Description

0-5000V 0-10000V High resistance box/Insulation resistance tester calibration device/Megohmmeter detection device

Product introduction
The insulation resistance meter verification device is based on the requirements of the relevant verification items in JJG1005-2019 "Verification Regulations for Electronic Insulation Resistance Meters" and JJG622-1997 "Verification Regulations for Insulation Resistance Meters (megohm meters)". And reference to the power industry standard DL/ T845.1-2004 "Electronic insulation resistance meter" general technical conditions in the design and manufacture of special equipment, used to verify the value error of electronic insulation resistance meter, drop voltage (Ud). With the constant speed device (KDCY3 type) produced by our company, the indicating error, open circuit voltage (Uk), median voltage (Uz), peak voltage (Uf) of the pointer megohm meter can be verified. It has the characteristics of compact structure, stable performance and easy to use. It is used by various industrial and mining, enterprises and institutions to verify all kinds of insulation resistance meter equipment.

Technical index
The insulation resistance meter verification device is mainly used to verify all kinds of insulation resistance meters with rated voltage ≤10kV, and can also be used as a standard instrument in the production and repair of insulation resistance meters. The resistor part can be used separately. The digital meter section can measure DC voltage up to 10000V.

0-5000V 0-10000V High resistance box/Insulation resistance tester calibration device/Megohmmeter detection device

(I) Standard table of figures

1, Measuring range: voltage range: 0 ~ 10000V

2. Basic error:
Dc voltage U

≤1000V: ± (0.4% reading +0.1% full degree)

 > 1000V: ± (0.5% reading +0.5% full degree)
Peak voltage (Uf)

≤1000V: ± (1% reading +0.5% full degree)

> 1000V: ± (0.5% reading +0.5% full degree)

3. The response time of the digital table is about 25 seconds.

(ii) Standard resistors

1, the standard resistor is composed of a series of 900G fixed resistance and nine resistance disks: 100GΩ+2×200GΩ+400GΩ+9×(104+103+102) MΩ+10 (10 +1+0.1+0.01+0.001+0.0001) MΩ, resistance range: 0 ~ 1000011.1110 MΩ, the minimum step is 100Ω, the maximum voltage is 10kV.

Decimal disk resistance Fixed resistance

×10000

×1000

×100

×10

×1

×0.1

×10

×1

×0.1

Rank index 5 2 1 0.5 0.2
Maximum operating voltage and current 10kV 5000V 2500V 500V 8 mA 20 mA 50 mA

0-5000V 0-10000V High resistance box/Insulation resistance tester calibration device/Megohmmeter detection device

2, the grade index of each decade and the highest use voltage or current.
3, the residual resistance value is less than 1Ω, the variation is not greater than 0.1Ω.
4, environmental reference conditions: 20+2-3 ºC, relative humidity: 50%±10%.
5, nominal use environment: temperature 23±5ºC, relative humidity: 25% ~ 60%.
6, the insulation resistance of the line to the shell: ≥1×1011Ω.
7. Power supply voltage: AC220V 50HZ.
8, overall size: 600mm×323mm×220mm.
9, weight: about 10kg.

0-5000V 0-10000V High Resistance Box/Insulation Resistance Tester Calibration Device/Megohmmeter Detection Device



0-5000V 0-10000V High Resistance Box/Insulation Resistance Tester Calibration Device/Megohmmeter Detection Device


0-5000V 0-10000V High Resistance Box/Insulation Resistance Tester Calibration Device/Megohmmeter Detection Device

0-5000V 0-10000V High Resistance Box/Insulation Resistance Tester Calibration Device/Megohmmeter Detection Device


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now