Integrated High Frequency High Voltage Power Supply Tester DC Electronic Load Machine

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 Year
Still deciding? Get samples of US$ 3000/Piece
Request Sample
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
6
Year of Establishment
2020-01-13
  • Integrated High Frequency High Voltage Power Supply Tester DC Electronic Load Machine
  • Integrated High Frequency High Voltage Power Supply Tester DC Electronic Load Machine
  • Integrated High Frequency High Voltage Power Supply Tester DC Electronic Load Machine
  • Integrated High Frequency High Voltage Power Supply Tester DC Electronic Load Machine
  • Integrated High Frequency High Voltage Power Supply Tester DC Electronic Load Machine
  • Integrated High Frequency High Voltage Power Supply Tester DC Electronic Load Machine
Find Similar Products

Basic Info.

Model NO.
KGGP-35A
Maxcapacity
<1000KN
Accuracy Grade
1
Load Way
Electronic Load
Display
Digital
Control
Manual Control
Weight
28
Power Source
AC220V
Output Voltage
0 ~ -35kv Continuously Adjustable
Built-in Capacitance
2.8UF/35kv
Pulse Period
3s ~ 8s Adaptive
Automatic Discharge
Automatic Discharge After Shutdown
Transport Package
Plywood Cases
Specification
48*37*45CM
Trademark
LONROY
Origin
Guangdong
HS Code
9024800000
Production Capacity
200

Product Description

Integrated High Frequency High Voltage Power Supply Tester KGGP-35A Power DC Electronic Load Machine

Transmitter characteristics

KGGP-35A integrated high frequency and high voltage power supply is the latest innovative generation of pure integrated high voltage power supply products developed by our company in combination with our long-term experience in cable fault testing and research and the current market demand, with stable performance, leading technology, portable and safe. The equipment meets the "People's Republic of China Power industry standard - General Technical Conditions for High voltage test equipment". This product adopts the principle of switching power supply, the maximum output of 35kV DC negative high voltage, the whole machine integrated design, stable performance, built-in capacitance, vacuum impact ignition, designed with emergency stop and automatic discharge function, safe and reliable. Supporting any cable fault tester of our company can easily use multiple pulse method or current flash method for rough measurement or predetermined location of cable fault, supporting cable fault locator can quickly and accurately locate the fault point, is an indispensable part of the cable fault test system.
This product is mainly used for high resistance fault waveform sampling impact discharge and precise point of fault in 35kV and below power cable fault test for impact discharge, it can also be used for high resistance failure of power cable burn through and ultra-high voltage 110KV cable outer sheath accurate point use, burn through the breakdown point in a short time, reduce the breakdown point resistance.

 

Integrated High Frequency High Voltage Power Supply Tester KGGP-35A Power DC Electronic Load Machine

Feature

1, pure integrated design, built-in capacitor, simple wiring;
2, touch screen human-computer interaction, simple setting and operation, intuitive and convenient instrument status display;
3, with voltage regulation, automatic voltage regulation and automatic protection functions;
4, the output high voltage has a single pulse and continuous pulse function, respectively with the fault tester and fixed-point instrument to find the fault point;
5, the output high voltage with DC output, can be external ball gap for work, diversified applications;
6, software control vacuum impact spark discharge, adaptive discharge and pulse period;
7, with emergency stop key, automatic discharge function, emergency stop or stop automatic step-down discharge, safe and reliable;
8, continuous working time is not less than 6 hours, to meet the maximum working time of cable fault test;
9, engineering chassis design, compact structure, small size, light weight, easy to carry.

 

Integrated High Frequency High Voltage Power Supply Tester KGGP-35A Power DC Electronic Load Machine

Parameter

Output mode: pulse output, DC output
Output voltage: negative pressure, 0 ~ -35kV continuously adjustable
Working current: ≤40mA
Working mode: single pulse, continuous pulse, DC output
Built-in capacitance: 2.8uF/35kV
Discharge energy: ≤1715J
Pulse period: 3s ~ 8s adaptive
Automatic discharge: automatic discharge after shutdown
Power supply: Power frequency 220V±10%
Display screen: 800×480 resolution touch screen
Operating temperature: -10ºC ~ 40ºC
Working humidity: ≤80%
Altitude: ≤1000 m
Overall dimensions: 478(L)*370(W)*448(H) mm
Weight: ≤28kg

Integrated High Frequency High Voltage Power Supply Tester DC Electronic Load MachineIntegrated High Frequency High Voltage Power Supply Tester DC Electronic Load Machine