Model | EED2005TG | |
Silence
|
output voltage | 0.2~± 20kV(±5%) |
Voltage holdup time | ≥5s | |
Output polarity
|
Positive, negative, first positive then negative, first negative then positive | |
Energy storage capacitance
|
150pF (standard) Other specifications can be selected according to the situation | |
Discharge resistor
|
330Ω (standard) Other specifications can be selected according to the situation | |
Discharge current rise time | 0.6 ~ 1ns | |
working form | The discharge interval can be set between 0.05 and 99.99s to meet various operation modes, such as 20PPS discharge; When the setting value is less than 0.05s, it is a single discharge | |
Discharge frequency setting | 1 ~ 9999 Or infinite times | |
Discharge modes
|
Contact discharge/air discharge |
|
Number of discharge
|
Can be preset 1-9999 times or unlimited times |
|
trigger mode |
1. Automatic 2. Manual 3. Automatic voltage gradient scan |
|
pulse |
output voltage | 0 .2~± 4.8KV±10% |
Output polarity
|
Positive or negative, alternating between positive and negative |
|
impulse frequency | 1kHz~1200kHz ± 10%, continuously adjustable | |
internal output impedance
|
50 Ω | |
pulse width | Load characteristic impedance 50 Ω 50ns ± 30% Load characteristic impedance 1k Ω 35 ns~150 ns |
|
Pulse train length | The value is adjustable from 1 to 255 | |
Pulse train period | Typical 300mS (0.15 -- 9.99S adjustable, precision 0.01S) | |
Coupling/decoupling network | Built-in single-phase three-wire power network AC MAX 250V 16A DC MAX 220V 16A |
|
test time | 1~9999S | |
weeks |
voltage variation range | 0% ~ 120% |
The duration of the voltage change | 1-9999 semi-cycle | |
Switching phase setting | 0 °~ 360 ° Or asynchronous resolution: 1° | |
The number of repetitions of voltage changes | 1-60000 time | |
Interval period of voltage change | 1-9999 semi-cycle | |
manner of working | Automatic, internal trigger | |
Capacity of the device under test | single phase,AC220V,10A | |
equipment | working power supply | AC220V 50/60Hz |
Dimensions
|
238*484*590mm | |
Power
|
300W | |