Liquid crystal display Transformer oil production gas detection solutions
Instrument introduction:
Transformer oil production gas detection solution is a multi-purpose gas chromatograph designed according to the standards issued by the Ministry of Electric Power, absorbing the advantages of similar instruments at home and abroad. The instrument adopts a double-column shunt column system with thermal conductivity and double hydrogen flame detector and reformer, which can realize the complete analysis of dissolved gas components in oil with one injection. The instrument is mainly used in the internal fault detection of oil-filled electrical equipment in power system. The instrument has the function of multi-purpose. It can be used for sulfur hexafluoride impurity analysis, hydrogen cooled generator cooling medium analysis, boiler flue gas analysis, natural gas analysis and environmental detection analysis. In addition, it is also widely used in oil. Chemical industry. Gas analysis of mining systems. |
Liquid crystal display Transformer oil production gas detection solutions
Main performance characteristics of transformer oil production gas detection solution:
1. Using microcomputer control, keyboard setting, LCD display, has the function of instant memory.
2. Detector signals, heater values, heating furnace temperatures, flow sensor readings or stored column compensation baseline signals can be distributed to a simulated output channel.
3. Automatic detection and fault diagnosis, power protection stored experimental data, stopwatch and running timer, keyboard locking function.
4. Hydrogen flame ion detector is easy to disassemble and install, easy to clean or replace the nozzle, simple operation; Input signal can be logarithmic amplification, reduce interference, high sensitivity, good linearity, wide range. American HP-5890 gas chromatograph micro thermal conductivity detector can be installed to achieve * docking.
5. High performance detector and methane converter, detection capacity * the power department for the determination of the content of gas components in transformer oil and environmental monitoring for trace CO, CO2 detection.
6. Using the secondary shunt column system, the analysis speed is fast and the reproducibility is good.
7. Double hydrogen flame design, so that low content of hydrocarbons and high content of CO, CO2 respectively detection, avoid mutual interference, improve the detection sensitivity.
8. The headspace sampler produced by our company can be installed to reduce the contamination of samples.