ASTM1149 ISO1431 Wire and Cable Rubber Plastic Ozone Resistance Aging Test Chamber

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 Year
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
6
Year of Establishment
2020-01-13
  • ASTM1149 ISO1431 Wire and Cable Rubber Plastic Ozone Resistance Aging Test Chamber
  • ASTM1149 ISO1431 Wire and Cable Rubber Plastic Ozone Resistance Aging Test Chamber
  • ASTM1149 ISO1431 Wire and Cable Rubber Plastic Ozone Resistance Aging Test Chamber
  • ASTM1149 ISO1431 Wire and Cable Rubber Plastic Ozone Resistance Aging Test Chamber
  • ASTM1149 ISO1431 Wire and Cable Rubber Plastic Ozone Resistance Aging Test Chamber
  • ASTM1149 ISO1431 Wire and Cable Rubber Plastic Ozone Resistance Aging Test Chamber
Find Similar Products

Basic Info.

Model NO.
GA-B012
Weight
0-100Kg
Power Source
AC220V
Transport Package
Plywood Case
Trademark
LONROY
Origin
China
HS Code
9024800000
Production Capacity
200pieces/Month

Product Description

ASTM1149 ISO1431 Wire And Cable Rubber Plastic Ozone Resistance Aging Test Chamber

1.name

Ozone aging test chamber

2.Product model

GA-B012

3.Sample restriction

This test equipment is prohibited:

Test or storage of samples of flammable, explosive and volatile substances

Testing or storage of corrosive substance samples

Testing or storage of biological samples

Testing or storage of samples of strong electromagnetic emission sources

4.Volume, size and weight

4.1.Nominal content product

150L

4.2.Inner size

W500*H600*D500mm

4.3.Appearance size

W950*H1750*D1000mm

4.4.Weight

About250

5.Property

5.1.Test the environment conditions

5.2.Test method

The ambient temperature is +25ºC, the relative humidity is less than 85%, and there is no sample in the test chamber

* In line with international standards of stainless steel test chamber and silent discharge to produce ozone fully closed gas loop, the entire ozone gas generation and capture are closed loop, to ensure personal safety.

* Set any ozone concentration in the range of 1000pphm.

* Speed regulating motor drives the sample rack device

(Meet the static tensile test, the specimen running track meets the cycloidal track principle)

* Ozone concentration automatic digital display control instrument.

* Dual beam "QUA" non-dispersive ultraviolet ozone detector.

* Digital display automatic online measurement.

* There is a metrological verification and correction interface.

* Ozone concentration/temperature and humidity setting value control PID self-tuning, easy to operate and reliable.

* 3rd generation Bill-Lambert measurement applications.

* Security door lock control system

5.3.Ozone concentration range

20 ~ 500 pphm(set direct reading)

5.4.Ozone concentration deviation

Ozone concentration deviation: 10% national standard

5.5.Test chamber temperature

Measuring range Room temperature ~ +70ºC (ozone generation temperature range)

5.6.Relative humidity

Measuring range below 60%RH (ozone generation humidity range)

5.7.Sample rack

360 degree rotating sample holder (static)

5.8.Dynamic stretching

Each fixture can be installed test piece tensile can meet the type dumbbell plate and the actual work piece dynamic work

5.9.Test gas flow

0-60L/min

5.10.Temperature range

0ºC→+100ºC(optional)

5.11.Humidity range

20-65%RH

5.12.Temperature fluctuation

±0.5ºC

5.13.Humidity fluctuation

±2.5%

5.14.Temperature deviation

±2.0ºC

5.15.Humidity deviation

±3.0%RH

5.16.Load status

no

5.17Working noise

A Sound level ≤70dB(A)

(Measured in a soundproof chamber with a ring temperature of 25ºC and little echo; The average value of 8 points is tested using A weight. Each test point is 1 meter above the noise source and 1 meter above the ground.

5.18.Meet test standards

Equipment for testing the ozone aging resistance of rubber and its products performs (meets) the relevant standards:

JIS K 6259 ASTM1149 ISO1431 GB/T7762 GB/T13642 etc

6.Structural feature

6.1. Thermal insulation enclosure structure

 

Outer wall material: A3 steel plate electrostatic spraying advanced stainless steel plate

Inner wall material: mirror stainless steel plate SUS#304.

Box insulation material: 100mm high temperature resistant rigid polyurethane foam.

Door insulation material: 100mm high temperature resistant rigid polyurethane foam.

6.2.Bottom structural strength

Test chamber bottom rail heavy capacity: ≤100Kg/m²(load), studio floor using 4mm channel steel integral welding.

6.3.Air conditioning channels

Stainless steel long-axis centrifugal fan: 1 set /90W.

Fan, heater, evaporator (and dehumidifier), drainage device, pressure balance port, adjustable air deflector, temperature sensor

 

6.4.Standard configuration of test chamber

Window 250x350x40mm 3 layer vacuum tempered glass.

Flat embedded handle,

Door hinge :SUS #304 inlet hinge

Energy-saving lamp in the box: LED light emitting mode

Lead hole: φ50mm 1 (with 1 rubber plug)

Ozone discharge outlet: φ50mm to outdoor

6.5. Door

Single door, open outwards, hinge on the left, handle on the right (when facing the front of the box).

(2) Equipped with a safety door lock mechanism (can open the door in the test room), the door with electric heat anti-condensation, the viewing range of the hollow glass observation window is about (W200×H280mm), a total of 2. The door frame is equipped with anti-condensation electric heating device

6.6.Control Panel

Domestic controller TEMI880 professional display, ozone aging display, equipment timer (0 ~ 99999 hours, non-returnable), overtemperature protection setting device, emergency stop switch, running indicator, fault indicator, buzzer, USB interface, with USB function can download curves and data.

6.7.Mechanical Room

Refrigeration unit, compressor water plate, pressure discharge device, heating device, spare sample test power supply

6.8.Power Distribution Cabinet

Switchboard, cooling fan, main power switch, device IO board, machine tool transformer, ballast, intermediate relay, time relay, solid state relay, AC contactor, thermal relay, fuse, circuit breaker

6.9.Heater

fin type heating pipe type stainless steel electric heater

Thermal control mode: SSR (solid state relay) contact-free periodic pulse width adjustment

Thermal power: about 2.5KW

6.10.Power cable hole and drainage hole

Located on the back of the case

 

8.Electrical control system

A)Controller model

TEMI880 touch intelligent programmable temperature controller

B)Controller specification

Technical indicators:

1. 5.7 "True color touch thin screen

2. Two control methods: program/fixed value

3. Sensor type: two PT100 inputs (optional electronic sensor input)

4. Output mode: Voltage pulse (SSR)/Control output: 2 (temperature/humidity) /2 4-20mA analog output /16 relay output (passive)

5. Control signal: 8 IS control signal /8 T control signal /4 AL control signal

6. Alarm signal: 16 DI external obstacle alarm

7. The temperature measurement range: 90.00 ºC, 200.00 ºC, (optional - 90.00 ºC, 300.00 ºC) error of plus or minus 0.2 ºC;

8. Humidity measurement range: 1.0%--100%RH, error ±1%RH;

9. Communication interface: (RS232/RS485, the longest communication distance is 1.2km[fiber up to 30km]);

10. Interface language type: Chinese/English

11. With Chinese input function;

12. Printer available (USB function optional);

13. A variety of signal combination relay output, signal can be logical operation (NOT,AND,OR,NOR,XOR),

PLC programming ability;

14. Relay control mode diversification: parameters -> Relay mode, relay -> Parameter mode, logical combination

Mode, composite signal mode;

15. Program editing: 120 groups of programs can be programmed, each group of programs can be programmed up to 100 segments;

16. With network function, IP address can be set;

17. Remote control instrument;

18. The product display is clear and intuitive, the programmable control system is flexible and convenient to operate, stable performance, more efficient work;

Specifications:

Size: 205 × 146 ×43 (mm) (length × width × depth)

Installation hole size: 172 × 133(mm) (L × W)
TFT:800×480 64K.

7.3Controller technical parameter

Accuracy: Temperature ±0.1ºC+1digit, humidity ±1%R.H+1digit

Resolution: Temperature ±0.01ºC, humidity ±0.1%R.H.

Temperature slope :0.1 ~ 9.9 can be set.

With upper and lower limit standby and alarm function.

Temperature and humidity input force signal dry and wet ball PT100x2.

9 groups of P.I.D control parameter setting,P.I.D automatic calculation.

Dry and wet ball automatic correction screen

7.4Control Mode

Anti-integral saturation PID

BTC balanced temperature control mode +DCC intelligent cooling capacity control +DEC intelligent electrical control (temperature test equipment)

BTHC balanced temperature and humidity control mode +DCC intelligent cold control +DEC intelligent electrical control (temperature and humidity test equipment)

7.4Screen display function

Screen conversation, no key input, screen directly touch options.

The temperature setting (SV) is displayed directly with the actual (PV) value.

Can display the current execution program number, segment, remaining time and number of cycles.

Run cumulative time function.

The temperature program setting value is displayed by graphical curve, with real-time display program curve execution function.

With a separate program editing screen, each page can input at least 5 segments of temperature and humidity and time.

English and Chinese can be switched at will.

The fault prompt screen is displayed.

The screen can be backlit.

The screen display protection function can be used for timing, TIMER or manual shutdown Settings.

7.5Program capacity and control functions

Groups of programs available: up to 120 PATTEN.

Available memory capacity: 12000 SEGMENTS.

Repeatable commands: Each command can be executed up to 3200 times.

The program is made in conversational style and has the functions of editing, clearing and inserting.

SEGMENTS is set to 0 to 99Hour59Min.

Programmable sequential control module device x2 group.

With power off program memory, automatically start and continue to execute the program function after the restart.

With RS-485 or RS-232 communication interface.

With USB interface function.

The graphic curve can be displayed in real time when the program is executed.

It has the function of automatically adjusting the freezing capacity.

It has the function of booking start and shutdown.

With date, time adjustment function.

Key and screen LOCK function.

3.Safety protection device

A)Test chamber

Adjustable overtemperature protection device

Air conditioning channel limit overtemperature

Fan motor overheating

B)Others

Total power supply phase sequence and phase loss protection

Leakage protection

Heating tube without air drying and burning protection

Overload and short circuit protection

Power-off protection

4.Other special instructions

A)Power cable

3-core (single-phase two-wire + PGND) cable 4 m 1 (available on request)

B)Wire hole

1 lead hole with rubber plug, diameter φ50mm specification, its position and quantity can be customized according to user requirements under the condition that the box structure allows and does not affect the performance

5.transport

Car packaging transportation

6.Conditions of Use

The following conditions

a)Installation site

Ground level, good ventilation

There is no strong vibration around the device

There is no strong electromagnetic field around the device

There are no inflammable, explosive, corrosive substances and dust around the equipment

Leave proper space for use and maintenance around the equipment, as shown in the following figure:

 

b)Environmental conditions

Temperature: 5ºC ~ 35ºC Relative humidity: ≤85% Air pressure: 86kPa ~ 106kPa

c)Water supply conditions

Softened deionized water is used in all external water supplies.

d) Power supply conditions

Power source

 

 

 

 

 

 

 

 

 

Power supply capacity

Maximum current

Power switch

AC220V single-phase + PGND cable

Allowable voltage fluctuation range: AC (220±10) V

Allowable frequency fluctuation range: (50±0.5) Hz

The grounding resistance of the PGND cable is less than 4 ohms

The user is required to configure the air or power switch of the corresponding capacity for the device at the installation site, and the switch must be independent for the device

About4.5 kW

25A

32A(Plastic-case leakage protector)

E)Requirements for storage environment

When the device is not working, keep the ambient temperature within 0 ° C to +45 ° C

When the ambient temperature is below 0 ° C, the water remaining in the equipment should be discharged clean, so as not to freeze the water in the pipeline and damage the pipeline (except for air-cooled machines).

 

Requirements for storage environment

number

name

Brand of origin

remark

other

1

Controller (including R232 communication and software)

China

U750

 

2

AC contactor

 

LC1D18,LC1D25

 

3

Thermal relay

 

LRD12C(5-8A)

 

4

intermediate relay

 

MY2J

 

5

Time relay

Taiwan CKC

AH3-3(3M)

 

5

DC switching power supply

Taiwan Ming Wei

DC24V

 

7

Overtemperature protection

Korean RAINBOW

TS-320S

 

8

SSR

aiwan Scholar Research

SSR-40DA

 

9

Temperature sensor

Taiwan One Power

PT100

 

10

Lighting

Philips

220V\9W

 

11

Signal Indicators

Taiwan TEND

TPWL5-220

 

12

Flashing buzzer

Shanghai Tianyi

LA42S

 

13

Control transformer

Tianzheng

300VA

 

14

Leakage protector

 

C100/3P+N+PE

 

15

button switch

Taiwan Tiande

LAS1-A

 

16

heater (heating)

Taiwan Longxing

custom

 

17

Circulation fan

Taiwan Mitsukoshi motor

220V90W

 

18

wind wheel

Taiwan Shangyu

6F

 

22

anti-sweat lin

Taiwan GOOLMAX

24VDC50W

 

23

multi-layer vacuum glass window

Hong Kong Qing Qiang

custom

 

24

high temperature line

China Chengtai

 

 

25

Wire and cable

China Chengtai

 

 

40

Circulating water pump

Nine stars

40W

 


ASTM1149 ISO1431 Wire and Cable Rubber Plastic Ozone Resistance Aging Test Chamber

ASTM1149 ISO1431 Wire and Cable Rubber Plastic Ozone Resistance Aging Test Chamber

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier