GA-2020 Portable Temperature Calibration Furnace Temperature Calibratior/Check Furnace
1.Overview:
Portable temperature calibration furnace with high stability temperature control instrument,The soaking block is made of superalloy material. Technically and domestically external advanced technology synchronization, at the insertion depth, horizontal temperature field, vertical temperature field and other technologies are at the leading level. In need for use in the temperature range, it is easy to set up and accurate generate the desired temperature. It has small size, fast heating and temperature control stability, no pollution and other characteristics, can be the temperature sensor and instrument
The table is verified as a whole, so it is easy to carry and use Easy, fast and reliable temperature calibration for a wide range of applications Machinery, chemical, food, medicine and other industries. Can detect (K/E/J /N /PT100/ and a variety of temperatures Meter).
Portable temperature check furnace design principle is easy to carry Belt, easy to use, easy to fast and reliable temperature calibration, Widely used in machinery, chemical, food, medicine and other industries.
GA-2020 Portable Temperature Calibration Furnace Temperature Calibratior/Check Furnace
2.Structure
The electric furnace with resistance structure is used in the portable dry body temperature calibration furnace a single
zero-crossing trigger module adjusts the temperature balance.
Portable temperature check furnace is also a conventional pit furnace. , inside part of the high-temperature alloy block as the equilibrium temperature, let its temperature in soaking heat
Under the action of the block, the temperature is kept balanced, and the test is opened above the soaking block with the jack, the thermocouple under test is inserted into the soaking block for detection. Let test balanced, can accurately calibrate the quality of thermocouple.
The calibration furnace adopts a large-screen LCD touch screen, and the operator fuck. Air-cooled structure, when the internal temperature of the calibration furnace reaches 600 degrees
The surface of the shell is still normal temperature.
GA-2020 Portable Temperature Calibration Furnace Temperature Calibratior/Check Furnace
3.Test method
The thermocouple will first be detected to be straight and then inserted into the furnace jack Within. You have to get to the bottom. Turn on the electric stove and set the desired temperature Degree. When the temperature PV temperature is close to SV for 20 minutes, the current test work can be carried out.
Note: The calibration furnace provides only one test temperature source, not for standard use