GA-V280 Automatic Characteristic IV Viscometer for polymer PET ISO1628 ISO307
I.Instrument design principle
The use of Ulster viscosity (viscosity) method to measure polymer or copolymer, Newton fluid kinematic viscosity, dynamic viscosity, viscosity ratio, viscosity number, specific concentration viscosity, increased viscosity, characteristic viscosity, polar viscosity number, polymerization degree, viscosity average molecular weight, etc.
II.Application field:
PET, PBT, PBAT, PBS, PA, PES, PVC, PAM, PAA, PVDF, ACR, POM, PAAS, HA, PLA, PGA, PLGA, PMMA, PEEK, PAN, PC, hyaluronic acid, aramid, polysulfone, cellulose, polysaccharide, silicone, oil, etc.
III.Applicable standards:
GB/T14190, GB/T17931, ISO1628, ISO307, ASMM D 446, Pharmacopoeia, etc.
GA-V280 Automatic Characteristic IV Viscometer for polymer PET ISO1628 ISO307
IV.Instrument function overview
1 or more measuring bit, with automatic measurement, automatic cleaning, automatic drying and data processing.(The number of stations can be customized according to customer requirements, automatic drying and automatic cleaning functions can be optional.)
GA-V280 Automatic Characteristic IV Viscometer for polymer PET ISO1628 ISO307
V.Equipment functions and features
Instrument structure |
l The instrument is a combination structure of intelligent modules. It can be combined according to the different technical requirements of users into a maximum to meet the user's needs of viscosity testing instruments. Each set is mainly composed of a control module, a measurement module and communication line, a cleaning module, a constant temperature bath, a temperature control module, a refrigeration module, Ukrainian viscometer, control software and PC. |
HT thermostatic bath and
WK temperature control module
|
l accommodated one measurement module.
l Material: stainless steel inner and outer bladder, double toughened glass window.
l double silo body design structure, to ensure the bath bath measuring area long-term consistency and temperature control accuracy
l with high and low liquid level alarm and ultra-high temperature protection function.
l Operating temperature range: 15 ~ 65ºC.
l Temperature fluctuation: ≤±0.01 ° C (with cooling module).
l Temperature display resolution: 0.01ºC. |
IV-MC
The control module |
l is the central module of the system and realizes the connection between the PC and other components.
l and the measurement module and PC communication interface is USB interface, very easy to plug and remove.
l 6 channel control system, up to 6 measuring stations can work at the same time. |
IV
The measuring module |
l contains capillary viscometers of different standards, such as Ulster viscometer, Pinner Viscometer, MicroAuster viscometer, Pinner Viscometer.
l has the functions of automatic constant temperature, sample lifting and timing. Only one USB communication cable is needed to connect to the control module.
l Armored stainless steel infrared optical fiber sensor.
l Applicable temperature range: 0 ~ 70ºC.
l Measurement time range: 0 ~ 9999.99s.
l Timing accuracy: 0.01s.
l Viscosity range: 0.3 ~ 50000 mm²/s(depending on the viscometer used). |
SCL
The cleaning module |
l has the functions of draining, cleaning and drying
l Each automatic cleaning module is equipped with an independent discharge pump, and the waste liquid is collected independently (optionally, the waste liquid is collected separately at each position).
l Cleaning and drying method: repeated cleaning, dual-air drying.
l The measurement module and cleaning module are designed in a split and one-to-one manner.
l Trial dose: < 13ml |
V1.0
The control and operation software |
l is used to calculate kinematic viscosity, dynamic viscosity, viscosity ratio, viscosity number, specific concentration viscosity, increased viscosity, intrinsic viscosity, polar viscosity number, degree of polymerization, viscosity average molecular weight, etc.
l provides the functions of measurement overmeasurement and permission management.
l has the functions of result query, report preview, long-term result analysis and statistics, export, connect printer to print reports, etc.
l Each station is controlled by a separate operating interface.
l Operation interface: Chinese or English |
Water, electricity, gas, etc
External conditions required
|
l 220V V,50 Hz, power: 2KW
l It is best to place the device in a fume hood or under a hood
l Temperature: -5 to 40ºC, humidity ≤75%RH (no condensation) |
VI.Main arrangement of instrument
Number |
Given name |
Type number |
count |
Reserve injection |
Standard configuration list |
1 |
Constant temperature bath tank body |
HTL-2 |
A set |
|
2 |
Temperature control module |
WK |
one |
|
3 |
Refrigeration module |
CR-400 |
A set |
|
4 |
Measurement module |
IV |
one |
USB cable included |
5 |
Automatic cleaning module |
SCL |
one |
|
6 |
automatic viscosity measurement software |
V1.0 |
A set |
|
7 |
Control module |
IV-MC |
A set |
|
8 |
Automatic Ulster viscometer |
pending |
1 |
Depends on the solvent required for the measured material |
9 |
Viscosity tube basket |
Conventional type |
1 |
|
10 |
Precision Mercury thermometer (accuracy 0.01ºC) |
22-27ºC |
1 |
It depends on the test temperature of the measured material |
11 |
Waste liquid bottle |
1L |
two |
|
12 |
Sample funnel |
|
one |
Sample tube containing PTFE material |
13 |
Installation package |
IV2S |
A set |
Includes instruction manual, warranty card, accessories, etc |
14 |
PC (Lenovo) |
Yang Tian M460 |
A set |
Motherboard with serial port |
Spare parts list |
1 |
Automatic Ulster viscometer |
pending |
1 |
Depends on the solvent required for the measured material |
2 |
Sample funnel |
|
one |
Sample tube containing PTFE material |
3 |
Seal washer |
trumpet |
1 pack |
10 PCS/packet |