• Libs Handheld X Series Laser Induced Breakdown Spectrometer
  • Libs Handheld X Series Laser Induced Breakdown Spectrometer
  • Libs Handheld X Series Laser Induced Breakdown Spectrometer
  • Libs Handheld X Series Laser Induced Breakdown Spectrometer
  • Libs Handheld X Series Laser Induced Breakdown Spectrometer
  • Libs Handheld X Series Laser Induced Breakdown Spectrometer

Libs Handheld X Series Laser Induced Breakdown Spectrometer

After-sales Service: Online
Warranty: 1 Year
Type: Laser Induced Breakdown Spectrometer
Weight: 0-100Kg
Power Source: AC220V
Power: Electronic
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
LIBS-X
Transport Package
Plywood Case
Trademark
LONROY
Origin
China
HS Code
9024800000
Production Capacity
200pieces/Month

Product Description

LIBS HandHeld X series laser induced breakdown spectrometer
Trade description

In recent years, laser-induced breakdown spectroscopy (LIBS) has become the preferred tool for geochemical analysis outside the traditional laboratory environment, testing a wide range of elements. Element measurement range atomic number. =1 (including organic elements such as C, H, O, light elements such as N, Li, Be, B, and almost all metals and non-metals) concentration range of 10ppm to % grade (depending on the element and instrument configuration) Analysis time generally about 20s sample form solid or powder (powder needs to be measured after pressing). Laser induced breakdown spectrometer is a new analytical means in the field of spectral analysis. Its basic principle is to use a high energy laser light source to form a high intensity laser spot (plasma) on the surface of the analytical material, so that the sample is excited to emit light, which is then analyzed by the spectral system and detection system. The e technique is sensitive to most inorganic elements in the material. At the same time, it can analyze low atomic number elements such as hydrogen - sodium elements, which are difficult to analyze with XRF technology

LIBS HandHeld X series laser induced breakdown spectrometer
Commodity parameter

Precise Elemental Analysis (LI-U)
The common handheld LIBS laser induced breakdown spectrometer (LIBS X-1688) is mainly used to test aluminum alloy, beryllium copper, carbon steel;
Specially made hand-held LIBS(LIBS X-898) for measurement of lithium in minerals, rocks and brines, pegmatite, clay and mica,

Intuitive operation
The Raspberry PI operating system and App-based software ensure quality inspection for each operator. Built-in WIFI and Bluetooth, with GPS capabilities, allows users to print, send email, and connect to almost any information management system for full-featured reporting. Automatically merge XRF and LIBS test services to easily manage operations anywhere.

Designed for outdoor and laboratory use
KMX-RAY LIBS Series Handheld Analyzer Weighing 1.65kg with Battery 2pcs (14.4v)
High-resolution rear display for easy viewing; Strong metal body for maximum durability;
Conical narrow nozzle for use at inaccessible test sites;
Argon can be replaced by users for a few cents per test and hundreds of tests can be performed.
Pair with PC or tablet profile generator software and achieve full desktop functionality.

Laser induced breakdown spectrometer is a new analytical means in the field of spectral analysis. Its basic principle is to use a high energy laser light source to form a high intensity laser spot (plasma) on the surface of the analytical material, so that the sample is excited to emit light, which is then analyzed by the spectral system and detection system. The e technique is sensitive to most inorganic elements in the material. It can also analyze low atomic number elements such as hydrogen - sodium elements, which are difficult to analyze with other techniques.

LIBS HandHeld X series laser induced breakdown spectrometer
LIBS HandHeld laser-induced breakdown spectroscopy has powerful technical advantages:


· Almost all natural elements can Be measured, including H, Li, Be, C, N, O, S and other elements that are difficult to be analyzed by conventional methods;

· The sample preparation process is very simple, and the sample surface can be cleaned or the surface coating can be removed by means of repeated pulses;

· Only a few samples (1-10g) can be used for high-throughput analysis, greatly reducing the cost of analysis;

· With ppm level detection limit and high sensitivity, detection precision and accuracy;

· Nondestructive testing in the real sense, only a tiny amount of sample is consumed, laser incident on the sample will hardly produce heating effect;

· Elemental analysis can be performed on samples in any physical state, including solid, liquid, gas and various mixtures;

· Almost unaffected by spectral interference;

· For all detectable elements, the analysis time is reduced to about 20 seconds, which has a significant advantage over other analytical techniques;

· Good environmental adaptability, almost no special requirements. Just connect the power supply can work, do not need water cooling and compressed air. Can meet the requirements of field experiment;

· Basically no periodic replacement of consumables, equipped with laser can be continuously used for more than 600,000 times;

· Powerful analysis software and spectral database compatible with Windows operating system.

LIBS HandHeld X series laser induced breakdown spectrometer
LIBS HandHeld X-1688 aluminum alloy version
    display 3.5-inch resistive touch screen 320 by 480 pixels
Core technology No X-ray ionizing radiation based on LIBS laser technology memory Internal standard storage 32GB
Model number LIBSHandheld X-1688 laser Class 3B 1064nm passive solid-state laser
weight 1.9 kg spectrograph <1.3nm resolution 170-1100nm spectral range
Size (length * width * height) 250mm*75mm*250mm Single test time 3s
battery 14.4V,6600mAh2 batteries High precision test mode

The average value of multiple single test values can be analyzed by the algorithm

WIFI 24GHz802.11n/b/a wireless network Alloy matrix Aluminum matrix
BLUETOOTH Bluetooth4.1Classic Low Power Bluetooth Testable element Al, B, Be, Bi, Co, Cr, Cu, Fe, Li, Mg, Mn, Mo, Nb, Ni, Pb, SiSn Si, Ti, V, zinc, Zr, Le (residual elements)
Sample type Cylindrical thin sheet wire foil with diameter of 1mm or above (~0.02mm), large pieces (no powder) Operating temperature Standard 0~40°C(32~100F) Recommended 5~35°C(40~95°F)
Detection line It varies according to different matrix and elements Remote mode The screen display can be projected onto a PC or mobile phone, and the test can be triggered remotely
database Including more than 100 most commonly used alloy brands available through KMAX software for advanced customization software Kmax client software (application update data download, brand library custom editing, test report generation, calibration file editing, etc.)
security Physical laser safety interlocking device Extended warranty service An extended warranty is available by purchasing an extended warranty
Routine maintenance Clean sample room with cotton swabs Spot check with supplied alloy standard sample field calibration with specified alloy standard sample to improve accuracy    

LIBS HandHeld X series laser induced breakdown spectrometer
LIBS HandHeld X-898 Ore Pro
technology Based on plasma emission spectrometer technology, no X - ray radiation hazard Display screen

35 inch resistive screen 320,480 pixels

Main engine (length * width * height) 250mm*75mm*270mm memory 32G
Main machine quality (including battery) 1.9kg Spectrometer parameter 460-690nm(670nm for Carp peak) resolution 0.2nm, imported from the Netherlands spectrometer
Battery specification 14.4V, 3300mAh/47.52Wh(16.8v Rechargeable) laser 100A,14mJ.10Hz
Steam flask Single use of the gas bottle, 350 times dosage, purity of 99.99% Test sample type Block, flake, powder tablet
Data transmission WIFI, Bluetooth, USB Detection limit

0.01% - 99.99%.

Operating system Raspberry PI Routine maintenance Use instrument cleaning kit to clean sample room, use sample control calibration instrument to improve accuracy
Operation language Chinese, English, Russian    
Libs Handheld X Series Laser Induced Breakdown SpectrometerLibs Handheld X Series Laser Induced Breakdown SpectrometerLibs Handheld X Series Laser Induced Breakdown SpectrometerLibs Handheld X Series Laser Induced Breakdown Spectrometer
Libs Handheld X Series Laser Induced Breakdown SpectrometerLibs Handheld X Series Laser Induced Breakdown SpectrometerLibs Handheld X Series Laser Induced Breakdown SpectrometerLibs Handheld X Series Laser Induced Breakdown SpectrometerLibs Handheld X Series Laser Induced Breakdown Spectrometer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now