High and low voltage buried trench buried cable multiple pulse cable fault locator detector
Functional characteristics
1 to test various types of 380 v, 6 kv, 10 kv, 35 kv, 110 kv220kv380kv voltage grade of copper aluminum core power cables coaxial communication cable and all kinds of local cable faults, such as open circuit fault, fault, high resistance flashover failure and high impedance leakage failure:
2. With a variety of test methods, such as low voltage pulse method, impact high voltage current sampling method, DC high voltage flashover method, etc.
3. The instrument is powered by high-energy polymer rechargeable battery, and the sample interface is USB direct microcomputer power supply. Coupled with advanced current sampling technology, the system truly realizes the operator and tester completely isolated from high voltage, strong anti-interference ability, and ensures the test reliability and man-machine safety;
4. The pre-sampling measurement unit adopts advanced signal processing technology, the full Chinese screen display, the test waveform characteristics are clear and easy to distinguish, making the cable fault analysis easier to master
5. Using WINCE operating system software, more user-friendly design, easy to operate;
6. The online service business carried out by the company is more convenient for users. As long as you send the test waveform to us by E-MAIL, you can get expert analysis and guidance on the same day. The company also regularly sends you the collected cable fault waveforms and their analysis results via E-MAL, so that you too will soon become an expert in cable fault testing
7. Dual trajectory and screen comparison data processing technology, conducive to your waveform comparative analysis 8. The use of industrial control embedded computer platform system, industrial use environment, to achieve strong stability. Potassium power supply Potassium power supply, convenient field test:
9. Multi-contact mouse and USB mouse operation, full computer XP operating platform integrated software, completely bid farewell to the era of cable instrument single-chip microcomputer, and equipped with cable fault test software and cable data management software;
10. Using the latest USB communication interface, the acquisition signal is stable, with a laptop computer can achieve dual control and dual display, the host can automatically select the minimum 3.25MHZ, up to 250MHZ eight kinds of sampling frequency, adaptive pulse width, can meet the test requirements of different lengths of cables, reduce rough measurement error:
11. The software realizes automatic identification and search of low-voltage pulse and multiple pulse method, automatic card position of waveform fault inflection point, automatic reading and display of fault distance instrument, waveform display in three areas of the same screen, and random display of ten low-voltage pulse waveform for selection on the same screen, and two modes of automatic and manual processing are realized at the same time.
12 Support the latest 4G communication terminal or wireless network card, dedicated 4G software can realize experts remote field real-time test technical services, experts remote control user host, to provide users with timely and accurate waveform analysis and communication guidance, so that you worry about work:
13.8G memory field waveform and field physical wiring diagram, can be used with a single click, cable data management software can do perfect cable file management, for cable maintenance work and accurate positioning to provide reference and help
14. The key precision fixed-point instrument part, the direct digital display tester distance from the fault point, is another innovation of similar fixed-point technology in China, for quickly and accurately find cable faults, reduce power failure loss provides a strong guarantee;
15. The newly developed intelligent combined sampler replaces the tedious field connection. It has the characteristics of intuitive waveform, easy analysis, complete isolation from high pressure, and absolute safety for the host and the operator.
16. Compatible with EXCEL documents, you can copy the content to the PLC input and output instructions table, do not need to fill in the input and output instructions table repeatedly, improve project design efficiency 10 Information in the manager supports copying and exporting to EXCEL; Insert or modify the I0 category at any time, and the page content is automatically refreshed :PLC manager's unique PLC management interface is convenient for the overall management of PLC, add PLC equipment, and associate PLC input and output; Dynamic PLC insertion, can set the direction of PLC connection point, can choose to draw the number of loops can be associated with input and output description, improve design efficiency; Macro configuration, by configuring the PLC macro loop, when drawing the PLC, the loop is automatically generated, the same macro loop is automatically labeled and numbered, and the common loop is drawn once and can be reused to improve the design efficiency.
High and low voltage buried trench buried cable multiple pulse cable fault locator detector
Cable fault repeatedly pulse range finder can test all kinds of 380 v, 6 kv, 10 kv35kv, 110 kv, 220 kv, 380 kv voltage grade, the different cross section all kinds of different media and all kinds of power cable fault, including: short circuit fault, open
circuit fault, low resistance, high leakage, high impedance arc fault.
It can test all kinds of faults of railway communication control cable, street lamp cable and airport signal cable. Can measure the speed of radio wave propagation in any cable of known length. Can test power cable buried path and buried depth multiple pulse generator: impulse voltage S40KV
Display mode :12.1 inches industrial LCD touch screen (XP operating platform)
Test distance: not less than 60KM Test accuracy: 03 meters
Operation mode: double operation, multi-contact touch and touch mouse operation
Test method: low voltage pulse method, lightning flow method, multiple pulse method, ten pulse method
Storage space: fixed 8G
Minimum test distance (blind area):0~0.5 m or no blind area
resolution :V/FM; V is the wave transmission speed M/MS; Software cursor 010m accurate fixed point error :0.2M
Test error: system error is less than 1%
Instrument sampling frequency :3.125MHZ, 6.25MHZ, 12.5MHZ, 25MHZ, 50MHZ, 100MHZ200MHZ, 250MHZ:
Pulse width :50NS, 80NS, 100NS, 20 0NS, 1MS, 2MS, 5MS, 10MS(software automatic matching)
Standby time: can be used continuously for about 6 hours
Weight :6KG
Dimensions :180MMX300MMX400MM
Ambient temperature :-20°C~+40C
Relative humidity :80%
Power consumption :AC220V10% no more than 15W
High and low voltage buried trench buried cable multiple pulse cable fault locator detector
High frequency high voltage power supply
Output mode |
pulse output, DC output |
Output voltage |
negative pressure, 0~-35KV continuously adjustable |
Working current |
S40MA |
Working mode |
single pulse, continuous pulse, DC output |
Built-in capacitance |
2UF/35KV(4UF/35KV) |
Discharge energy |
S2450J |
Pulse period |
3S~8S adaptive |
Automatic discharge |
Automatic shutdown discharge |
The working power frequency |
220V 10% |
Operating temperature |
-10°C~40°C |
Working humidity |
≤80% |
Altitude |
≤1000 m |
Dimensions |
478(L)*370(W)*448(H)MM |
Weight |
≤28KG |
Intelligent precision fixed-point instrument
Sensor dynamic range: |
sound channel >104DB, magnetic field channel >110DB |
sensor frequency range |
100HZ~1500HZ |
Impact discharge sound amplification factor > 90DB, impulse discharge volume Upper limit 84DB(A) Filter Settings can be enabled or disabled
: No filter 100HZ to 1500HZ |
No filter |
100HZ to 1500HZ |
Low-pass filtering |
100HZ~400HZ |
Band pass filtering |
150HZ~600HZ |
High-pass filtering |
200HZ to 1500HZ |
Step voltage signal cursor is displayed visually, the left and right prompts are obvious. |
LCD display |
high light true color screen, 320X240 pixels suitable for outdoor. |
Field continuous working time |
alkaline replaceable battery battery, easy to use on site. |