Astmd5289 Rubber No Rotor Rheometer ISO6502 Moving Die Rheometer

Product Details
Customization: Available
After-sales Service: Online Support
Warranty: 1year
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
6
Year of Establishment
2020-01-13
  • Astmd5289 Rubber No Rotor Rheometer ISO6502 Moving Die Rheometer
  • Astmd5289 Rubber No Rotor Rheometer ISO6502 Moving Die Rheometer
  • Astmd5289 Rubber No Rotor Rheometer ISO6502 Moving Die Rheometer
  • Astmd5289 Rubber No Rotor Rheometer ISO6502 Moving Die Rheometer
  • Astmd5289 Rubber No Rotor Rheometer ISO6502 Moving Die Rheometer
  • Astmd5289 Rubber No Rotor Rheometer ISO6502 Moving Die Rheometer
Find Similar Products

Basic Info.

Model NO.
LR-A018
Mass Scope of Workpiece
<900kg
Type
Rubber No Rotor Rheometer
Maxcapacity
<1000KN
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
No
Model
Lr-A018
Standard
ASTM D5289 ISO6502
Name
Rubber No Rotor Rheometer
Power
2 Kw
Transport Package
Plywood Box
Trademark
lonroy
Origin
China
HS Code
9024800000
Production Capacity
200PCS/Month

Product Description

ASTMD5289 Rubber No Rotor Rheometer ISO6502 moving die rheometer
Introduction and Overview

The rotor-free vulcanizer is the most widely used instrument in the rubber processing industry to control the quality of rubber, rapid inspection and basic research of rubber. It provides accurate data for the optimized formula combination of rubber, and can accurately determine the parameters such as coke burning time, positive vulcanization time, vulcanization index and maximum and minimum torque.
The vulcanization meter consists of: host, computer, temperature measurement, temperature control, data acquisition and processing, sensor and electrical linkage, etc.The measurement and temperature control circuit is composed of measurement and control module, platinum resistor and heater, which can automatically track the change of power grid and environmental temperature, and automatically correct PID parameters, so as to achieve the purpose of fast and accurate temperature control.The data acquisition system and the electromechanical linkage can automatically detect the moment signal of rubber vulcanization process and automatically display the temperature value and set value in real time.After curing, automatic processing, automatic calculation, printing curing curve and process parameters.Display curing time and curing moment.The computer displays the vulcanization process in real time, from which the change of "temperature" and the change of "time-torque" can be clearly seen.
 
ASTMD5289 Rubber No Rotor Rheometer ISO6502 moving die rheometer
Machine features

This test instrument has the following characteristics:
A. High precision and wide range of temperature control.(plus or minus 0.1 ºC)
B. Clock programming function.(Setting and modifying time)
C. Technologically advanced switching power supply, wide range of voltage regulation.
D. Imported integrated circuits and control components.
E. English language.
F. Meet the requirements of GB/T16584 (rubber vulcanization characteristics tested with a rotor-free vulcanization meter) and ISO6502.
The powerful microprocessor USES high quality imported chips.For one thing, computers and microprocessors can take signals from torque sensors and record them on graphs.At the same time, the computer and the module interface for data exchange, and control the cavity temperature.
The rotor-free vulcanizer was designed with a series of interlocking features, including closing plastic glass doors.If the door is not closed, the mold cannot close.Only when the door is securely closed can the mold be closed.In order to work.
In a word, compared with other models, this type of vulcanizer is more stable in performance, more accurate, cheaper in quality and complete in function.It is the best instrument for testing rubber properties.
 
ASTMD5289 Rubber No Rotor Rheometer ISO6502 moving die rheometer
Technical specifications
The standard of the vulcanization meter ASTMD5289-95 ISO6502-1999 (E) GB/T16584-1996
 
Temperature range  room temperature --200ºC
Temperature measurement accuracy  ≤±0.1ºC when 100-200 ºC
Temperature control stability ≤±0.1ºC at 100-200 ºC
Setting range 0-200 ºC;Set the minimum unit: 0.1ºC
Set the time range 0-200 ºC;Display resolution: 0.1ºC
Automatic range switching increases automatically according to the actual torque
Power supply  50HZ, ~ 220V±10%, 50±1Hz, must be well grounded
Compressed air 0.32mpa controlled by pneumatic control valve
Oscillation frequency 100 times/min (about 1.7Hz)
Ambient temperature normal temperature --40ºC, relative humidity less than 80%, no corrosive gases in the air
Material quality 250 kg
Power 2 kw
Dimensions 680×630×1100 (mm)

Astmd5289 Rubber No Rotor Rheometer ISO6502 Moving Die RheometerAstmd5289 Rubber No Rotor Rheometer ISO6502 Moving Die RheometerAstmd5289 Rubber No Rotor Rheometer ISO6502 Moving Die RheometerAstmd5289 Rubber No Rotor Rheometer ISO6502 Moving Die RheometerAstmd5289 Rubber No Rotor Rheometer ISO6502 Moving Die Rheometer

















 