• Kgrb-II Transformer Winding Deformation Tester (embedded in computer) Short Circuit Impedance Tester
  • Kgrb-II Transformer Winding Deformation Tester (embedded in computer) Short Circuit Impedance Tester
  • Kgrb-II Transformer Winding Deformation Tester (embedded in computer) Short Circuit Impedance Tester
  • Kgrb-II Transformer Winding Deformation Tester (embedded in computer) Short Circuit Impedance Tester
  • Kgrb-II Transformer Winding Deformation Tester (embedded in computer) Short Circuit Impedance Tester
  • Kgrb-II Transformer Winding Deformation Tester (embedded in computer) Short Circuit Impedance Tester

Kgrb-II Transformer Winding Deformation Tester (embedded in computer) Short Circuit Impedance Tester

After-sales Service: Online
Warranty: 1 Year
Type: Transformer Winding Deformation Apparatus
Maxcapacity: <1000KN
Accuracy Grade: 1
Load Way: Electronic Load
Samples:
US$ 3000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
KGRB-II
Display
Digital
Control
Manual Control
Weight
30
Power Source
AC220V
Amplitude Measurement Range
(-120dB) to (+20dB)
Amplitude Measurement Accuracy
0.1dB
Scanning Frequency Accuracy
0.005%
in Phase Test Repetition Rate
99.9%
Transport Package
Plywood Cases
Specification
40*30*30CM
Trademark
LONROY
Origin
Guangdong
HS Code
9024800000
Production Capacity
200

Product Description

KGRB-II Transformer Winding Deformation Tester (embedded in computer) Short Circuit Impedance Tester

Product Introduction

KGRB-II transformer winding deformation tester (embedded computer) by detecting the amplitude-frequency response characteristics of each winding of the transformer, and comparing the detection results vertically or horizontally, according to the degree of change in amplitude-frequency response characteristics, judge the winding deformation that may occur in the transformer.
KGRB-II transformer winding deformation tester (embedded computer) has the function of linear sweep frequency measurement and segmented sweep frequency measurement dual measurement system, compatible with the current two domestic technical schools of measurement mode.
KGRB-II transformer winding deformation tester (embedded in computer) is convenient to carry, high-speed dual-channel 16-bit A/D sampling (field test changes the tap-changer, the waveform curve has a clear change).

 

KGRB-II Transformer Winding Deformation Tester (embedded in computer) Short Circuit Impedance Tester

Product Parameters
1, amplitude measurement range: (-120dB) to (+20dB)
2, amplitude measurement accuracy: 0.1dB
3, scanning frequency accuracy: 0.005%
4, signal input impedance: 1MΩ
5, signal output impedance: 50Ω
6, signal output amplitude: ±20V
7, in phase test repetition rate: 99.9%
8, measuring instrument size (length width height)340X240X210(mm)
9, instrument aluminum alloy box size (L W H)410X360X350(mm), wire box aluminum alloy box size (L W H)420X300X300(mm)
10. Total weight :30Kg

 

KGRB-II Transformer Winding Deformation Tester (embedded in computer) Short Circuit Impedance Tester

Product Characteristics
1, acquisition control using high-speed, highly integrated microprocessor.
2. USB interface for communication between laptop and instrument.
3, the hardware movement adopts DDS special digital high-speed sweep frequency technology (USA), through the test can accurately diagnose winding distortion, bulge, shift, tilt, turn short circuit deformation and interphase contact short circuit and other faults.
4, high-speed dual-channel 16-bit A/D sampling (field test changes the tap-changer, the waveform curve has a clear change).
5, signal output amplitude software adjustment, the maximum peak ±10V.
6, the computer will automatically analyze the test results and generate electronic documents (Word).
7, the instrument has linear sweep frequency measurement and segmented sweep frequency measurement dual measurement system function, compatible with the current domestic two technical schools of measurement mode.
8, amplitude-frequency characteristics in line with the national amplitude-frequency characteristics tester technical indicators. The horizontal coordinate (frequency) has two kinds of linear indexing and logarithmic indexing, so the printed curve can be a linear indexing curve or a logarithmic indexing curve, and users can choose according to actual needs.

9, detection data automatic analysis system
(1)The winding similarity is compared between the three phases A, B and C
(2)The analysis results are as follows:
(3)The consistency is good
(4)Good consistency
Poor consistency
Poor consistency,
Longitudinal comparison A-A, B-B, C-C The winding deformation is compared between the original data and the current data in phase

The analysis results are as follows:
(1)Normal winding
(2)Mild deformation
(3)moderate deformation
(4)Severe deformation
10, can automatically generate Word electronic documents for saving and printing.
11, the instrument fully meets the technical conditions of the power standard DL/T911-2004 "Frequency response Analysis of power transformer winding deformation".

Kgrb-II Transformer Winding Deformation Tester (embedded in computer) Short Circuit Impedance TesterKgrb-II Transformer Winding Deformation Tester (embedded in computer) Short Circuit Impedance Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company
Number of Employees
6
Year of Establishment
2020-01-13