Minimum Film Forming Temperature Tester /Mftt Film Forming Temperature Test Equipment

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1year
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
6
Year of Establishment
2020-01-13
  • Minimum Film Forming Temperature Tester /Mftt Film Forming Temperature Test Equipment
  • Minimum Film Forming Temperature Tester /Mftt Film Forming Temperature Test Equipment
  • Minimum Film Forming Temperature Tester /Mftt Film Forming Temperature Test Equipment
  • Minimum Film Forming Temperature Tester /Mftt Film Forming Temperature Test Equipment
Find Similar Products

Basic Info.

Model NO.
LR-G018
Specification
520mm*520mm* 370mm
Trademark
LONROY
Origin
Dongguan
HS Code
9024800000
Production Capacity
5000PCS Per Year

Product Description

Minimum Film Forming Temperature Tester /MFTT Film Forming Temperature Test Equipment
  Description
:When emulsion polymer is used to produce paint, adhesive, chemical blended fabric, surface treatment agents for leather or paper, its film forming property is very important. Apply an emulsion polymer or emulsion paint on the metal board, when the water has been evaporated, polymer particles would form a continuous and transparent film because of interaction under suitable temperature. The ultimate temperature of critical film forming is called as minimum film forming temperature for this emulsion polymer, short for MFT temperature.
 
Minimum Film Forming Temperature Tester /MFTT Film Forming Temperature Test Equipment
        Tester Principle:
Set a cooling source and a heating source on a suitable metal board and keepthem at a constant temperature to setting point. Different temperature grads would appear on this board because of metal heat conduction. Paint uniform thickness sample on this temperature grads board, the water of sample will be evaporated under heating of different temperature and sample will form film. The form film performance is different under different temperature. Find the boundary and then its corresponding temperature is MFT temperature of this sample.
 
Minimum Film Forming Temperature Tester /MFTT Film Forming Temperature Test Equipment
        Minimum Film Forming Temperature Tester(MFTT)is the newest  high-precision product which has been developed. We use platinum resistance imported from Germany as temperature sensor, and use LU-906M intelligent temperature controller which combine fuzzy control theory with PID control , ensure it shows an error less than 0.5%±1 bit. In order to reduce size, we use special size grad board at all costs. Furthermore, there is water-break protection system for any water break, the machine will turn off automatically once there is water-break. For saving water consumption, we let tester screen show cooling water temperature (on the 15th and 16th point of inspection recorder), decrease the water consumption as far as possible(by hand) according to different settings. In order to let operator judge MFT point successfully, we design clear and high graduated scale in the front of the working table.
        It is accordance with ISO 2115, ASTM D2354 standard, and can test minimum film temperature of emulsion polymer easily and accurately.
 
Minimum Film Forming Temperature Tester /MFTT Film Forming Temperature Test Equipment
Advantages

 Wider working table, can test 6 groups sample at the same time.
 Space saving desktop design.
 Advanced design for grad board decreases the machine size.
 Surface temperature is calibrated precisely, ensuring a accurate and reliable data with temperature scale .
 Intelligent temperature controller, ensures error is less than0.5%±1 bit.
 Cooled by semiconductor and big power switching voltage decreases noise from cooling system considerably
 
Minimum Film Forming Temperature Tester /MFTT Film Forming Temperature Test Equipment 
Main Technical Parameters

 Working temperature of grad board:-7ºC~+70ºC
 Number of inspection points of grad board:13 pcs
 Interval distance of grad:20mm
Test channels:6 pcs, length is 240mm, width is 22mm and depth is 0.25mm
 Showing value of inspection recorder:16 points,from No.1 ~ No.13 is working temperature grade, No.14 is environment temperature, No.15 and No.16 are cooling water temperature for inlet and outlet
 Power:220V/50Hz AC wide voltage(three-phase supply with good earth)
Cooling water:Normal water supply
 Size:520mm(L)×520mm(W)× 370mm(H)
 Weight:31Kg
 
 Minimum Film Forming Temperature Tester /Mftt Film Forming Temperature Test EquipmentMinimum Film Forming Temperature Tester /Mftt Film Forming Temperature Test Equipment

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier