• Kg6200 Oil Dielectric Loss and Resistivity Tester Insulating Oil Tangent Delta Device
  • Kg6200 Oil Dielectric Loss and Resistivity Tester Insulating Oil Tangent Delta Device
  • Kg6200 Oil Dielectric Loss and Resistivity Tester Insulating Oil Tangent Delta Device
  • Kg6200 Oil Dielectric Loss and Resistivity Tester Insulating Oil Tangent Delta Device
  • Kg6200 Oil Dielectric Loss and Resistivity Tester Insulating Oil Tangent Delta Device
  • Kg6200 Oil Dielectric Loss and Resistivity Tester Insulating Oil Tangent Delta Device

Kg6200 Oil Dielectric Loss and Resistivity Tester Insulating Oil Tangent Delta Device

After-sales Service: Online
Warranty: 1 Year
Type: Dielectric Loss and Resistivity Tester
Maxcapacity: <1000KN
Accuracy Grade: 1
Load Way: Electronic Load
Samples:
US$ 3000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
KG6200
Display
Digital
Control
Manual Control
Weight
35
Power Source
AC220V
High Voltage Output
0.5 ~ 10kv
Power
AC 220V 10% 50 1Hz
Harmonic Adaptation
<3%
Relative Humidity
< 80%
Transport Package
Plywood Cases
Specification
46*35*35CM
Trademark
LONROY
Origin
Guangdong
HS Code
9024800000
Production Capacity
200

Product Description

KG6200 Oil Dielectric Loss and Resistivity Tester Insulating Oil Tangent Delta Test Device 

Product Introduction

KG6200 precision oil dielectric loss tester is designed and manufactured according to GB/T5654-2007 "Measurement of relative permittivity, dielectric loss factor and DC Resistivity of Liquid Insulating Materials". Used for measuring dielectric loss factor and DC resistivity of liquid insulating medium such as insulating oil. An integrated structure. The internal integrated dielectric loss oil cup, temperature controller, temperature sensor, dielectric loss test bridge, AC test power supply, standard capacitor, high resistance meter, DC high voltage source and other main components.
KG6200 precision oil media loss tester adopts all-digital technology, all intelligent automatic measurement, equipped with a large screen 5.7 inch TFT pure color LCD touch display, full Chinese menu, test results can be automatically stored and printed out, operators do not need professional training can be skilled use.

 

KG6200 Oil Dielectric Loss and Resistivity Tester Insulating Oil Tangent Delta Test Device 

Product Characteristics
1, the oil cup adopts the three-electrode structure in line with the national standard GB/T5654-2007, the electrode spacing is 2mm, which can eliminate the influence of stray capacitance and leakage on the dielectric loss test results.
2, the instrument adopts medium frequency induction heating, PID temperature control algorithm. The heating method has the advantages of non-contact between the oil cup and the heating body, uniform heating, fast speed, convenient control, etc., so that the temperature is strictly controlled within the preset temperature error range.

3, the internal standard capacitor is SF6 inflatable three-pole capacitor, the dielectric loss and capacitance of the capacitor are not affected by ambient temperature, humidity, etc., so that the accuracy of the instrument is still guaranteed after a long time of use.

4, AC test power supply using AC-DC-AC conversion mode, effectively avoid the mains voltage and frequency fluctuations on the dielectric loss test accuracy, even if the generator generation, the instrument can operate correctly.

5, perfect protection function. When there is overvoltage, overcurrent, high voltage short circuit, the instrument can quickly cut off the high voltage, and send a warning message. A warning message is issued when the temperature sensor fails or is not connected. A limited temperature relay is provided in the medium frequency induction heating furnace. When the temperature exceeds 120 degrees, the relay is released and the heating stops.

6. Convenient setting of test parameters. The temperature ranges from 0 to 120 ° C. The AC voltage ranges from 200 to 2200V. The DC voltage ranges from 0 to 500V.

7, the use of large screen TFT pure color LCD touch display, clear display. With a simple setup, the instrument can be tested automatically. And automatically store and print test results.

8, with real-time clock, test date and time can be saved, displayed and printed with the test results.

9, empty electrode cup calibration function. Measure the capacitance and dielectric loss factor of the empty electrode cup to judge the cleaning and assembly condition of the empty electrode cup. Calibration data is automatically saved to facilitate accurate calculation of relative permittivity and DC resistivity.

10, the instrument with RAM9 platform as the core, high test accuracy, fast speed.

 

KG6200 Oil Dielectric Loss and Resistivity Tester Insulating Oil Tangent Delta Test Device 

Product Parameters
1, high voltage output: 0.5 ~ 10kV,
Each gear increases 500V, a total of 20, capacity: 1500VA2, accuracy: tgδ: ±(reading *1%+0.06%)
Cx: ±(Reading *0.5%+5PF)

3. Resolution: tgδ : 0.001%Cx: 0.001pF

4, measuring range: 0.001% < tgδ < 100%
Internal application high voltage: 3pF ~ 60000pF/10kV 60pF ~ 1µF/0.5kV
Applied high voltage: 3pF ~ 1.5µF/10kV 60pF ~ 30µF/0.5kV

5, power source: AC 220V 10% 50 1Hz

6, measurement method: a. Single frequency: 45Hz, 50Hz, 55Hz, 60Hz, 65Hz
b. Different frequency: 45/55Hz, 55/65Hz, 47.5/52.5Hz automatic double frequency conversion

7, harmonic adaptation: ≤ 3%

8, the use of conditions: -15ºC-50ºC relative humidity < 80%

9, Appearance size: 460 (L) ×345 (W) ×345 (H)

10, weight: 35 kg

Kg6200 Oil Dielectric Loss and Resistivity Tester Insulating Oil Tangent Delta DeviceKg6200 Oil Dielectric Loss and Resistivity Tester Insulating Oil Tangent Delta Device

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now