BGD 897 High-Low Temperature Humidity Cabinet Programmable Constant Temperature Humidity Device

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2020-01-13
Number of Employees
6
  • BGD 897 High-Low Temperature Humidity Cabinet Programmable Constant Temperature Humidity Device
  • BGD 897 High-Low Temperature Humidity Cabinet Programmable Constant Temperature Humidity Device
  • BGD 897 High-Low Temperature Humidity Cabinet Programmable Constant Temperature Humidity Device
  • BGD 897 High-Low Temperature Humidity Cabinet Programmable Constant Temperature Humidity Device
  • BGD 897 High-Low Temperature Humidity Cabinet Programmable Constant Temperature Humidity Device
  • BGD 897 High-Low Temperature Humidity Cabinet Programmable Constant Temperature Humidity Device
Find Similar Products
  • Overview
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
BGD 897
Power Supply
220V/380V; 50HZ
Total Power
5.5 KW
Humidity Stability
±2% RH
Temperature Stability
±0.5 ºC
Transport Package
Plywood
Trademark
LANGSHUO
Origin
Changsha
HS Code
9024800000
Production Capacity
200

Product Description

 

BGD 897 High-Low Temperature Humidity Cabinet Programmable Constant Temperature Humidity Device

Description:
   
These new programmable cabinets with a precise system of temperature and humidity control, which provide various necessary environmental simulative conditions for industrial research and biotechnology tests. Widely applied in sterile tests and stability check-up of pharmaceuticals, textile and food processing as well as tests in material performance, packing and lifetime of industrial products.
Biuged launched the latest generation climate chambers which has the following updates compared to previous products or competitors prodcuts:
1.Use electronic humidity sensors to control and display the relative humidity of the working room, more convenient , more accurate.
This new design avoids many inconveniences and issues come from the previous method of using PT 100 platinum resistance for wet and dry bulb measurements. For example there is no need to regularly replace the wet bulb fabric, and some users may forget to replace it or hang it incorrectly, resulting in wrong humidity readings or the inability to control humidity during the test.
2. The refrigeration control system adopts an electronic expansion valve to control the cold end balance, which, under the same test conditions, can save at least 40% power compared to products using thermal balance methods. It also reduces water consumption by more than 60%.
3. Using a scroll compressor results in a larger cooling capacity and lower noise.


Feature:

1.0  Structure  Feature
Chamber Structure Internal material:304# stainless steel with thickness is 1.2mm
External material:1.2mm baking finish cold roll steel plate with advanced static electricity spray process.
Heat preservation material: polyurethane foam rubber with 100 mm thick
Others:install the positioning foot cup and movable trundles under the test chamber bottom; top of chamber equips automatic pressure relief hole, bottom of inner chamber equips drainage hole, can drain out condensate water quickly
      Air Adjustment
            Channel
Inside air space, recirculating wind channel and stainless steel cycle fan, through the top   window and air diffuser, the wind will out uniformly from the top, let the reconciled temperature from the harmonic room diffuses to the test area, which could   reach the purpose of control temperature uniformly.
Chamber Door *Single open door
*Anti-explosion
*Anti-condensation electric heating device
*Vacuum auto-defog transparent window
*Window floodlight
Cable Port Install a ¢ 50mm test hole on the left of the machine, and equip related seal device for connecting with power test
View Window designed in the door with 230*270mm transparent electric radiant heating film with cavity toughened glass(equipped with   anti-condensation function)
Control System TEMI 1500 Touch Screen LCD, imported from Korea, floodlight switch,main power switch
Cooling System refrigeration system, heating device, fan, dewatering device, adjustable back window
Sample Shelf adopt 304# stainless bent into net sharp, easy for use, the distance between the material frame could be adjusted(the smallest distance is 50mm),standard   equipped two pieces
Electrical Room main power breaker, controller, distribution plate, radiating fan, over temperature protector
Heating System adopt the scale heat rejection heating pipe P.I.D. control the heating so let the temperature gets the balance
2.0  Refrigerating System
Refrigeration Method to keep the cooling rate and minimum temperature requirement,we use single stage refrigeration system
       Refrigeration
        Compressor
adopt low temperature compressor from European
Cooling System air-cooled scale condenser, circulating fan for heat dissipation
Evaporimeter finned tube heat exchanger
Throttling Device thermostatic expansion valve ,capillary tube
Dry filter absorption for the residual water and acidic material from refrigerating fluid in refrigerating system, filtrate the solid impurity grain, copper cuttings of   system, keep the normal working of expansion valve and capillary, in case of   ice blockage and filth blockage
Refrigerating  Fluid adopt environment protected refrigerating fluid R404A
3.0  Electrical  Control System
Controller Korea SAMWON, LCD touch screen controller TEMI 1500
Display Interface * Display screen dimension:5.7 inches colorful touch screen conversational mode
*Temperature set value(SV), current   value(PV)displays   directly
*Can display the temperature output value
*The execute program number, section, procedure time and time signal control condition can be displayed
*Can display auto-calculus picture and procedure standby light-flooding picture
*Can display record data and curve condition picture
*Can display current curve and edit procedure curve and history running curves
*Can display fault indicated and simple fault exhaust
Procedure Capacity          And Control
         Function
*Operational procedure capacity:max:120 groups;one procedure could consist of 1 to 99 sections.
*Operational memory capacity:1200 sections, could repeat   executive command: each command could repeat 999 times, the slope setting of   the procedure could be set through the timer shaft, the jointing use could be set among the   procedures, the   procedure making can adopt dialogue type, easy to operate with edit,   eliminate and insert function, 4 groups of time signal output control (can   control the test sample ON/OFF option).
*9 groups of PID parameter setting, the procedure will have the overleap section, keep functions; can show the curve and data collection;  date and time adjustment function; button and picture lock(LOCK) function;  can connect the computer, 8 points of DI abnormal input and 10 points of DO   signal control
Communication RS-232 communicate interface, can used as monitoring and remote control system,  record the test data
Running Method program mode / definite value mode
Set Method English interface, touch screen input
SD Storage Card Used to store test date and test curve, standard storage capacity is 2G, storage time   is about 2 years
Setting Range up/down limitation of maximum temperature range is 5ºC
Display Resolution temperature:  0.01ºC;   time: 1min;
   Memory Function
     when Power off
can set recovery mode in case of power off : heating/ cold/ stop
 Make anappointment               function can set available machine time randomly, after turn on the power, the machine will run automatically
Input PT100 type platinum resistor
        Curve record
             function
equip with battery protection RAM, can save the set value, sampling value and sampling time of the machine;Max record time is 60 days(when the sampling cycle is 1.5min)
         Software use
          environment
IBM PC compatible machine, above PII CPU,   more than 128M RAM, simplified Chinese Windows2000 or simplified Chinese WindowsXP operation system.
Circulating fan low   noise with many wing centrifugal fan
Heater import nichrome electronic heater and   heater control mode is contactless equal cycle recurrent pulse adjust wide,   SSR(solid-state   relay)
Control Mode anti-integral saturation PID, BTC balance adjust temperature control mode(temperature test equipment)
4.0 Humidify and Dehumidify System
Water Supply Big water tank
Humidify And Dehumidify   Method Adopts outer humidify, compressor   start to dehumidify, P.I.D controls the humidify volume to reach the need   humidity
       Water Quality
           Request
Resisitivity ≥500Ω·m
Water   Supplement Method Chamber reserves the water supplement port and water level viewing window, please supply   water when the water level is too low
       Humidify Water
             Supply
Inner equipped with a micro water pump, and only needs   to add water to the water tank. The water pump is automatically added to the   humidifying boiler according to the water level in the humidifying boiler
5.0 Safety Protection Device
          Refrigerating                   System compressor overheat/over current/ over pressure, condensation fan overheat
Test Chamber over temperature limitation, fan/motor over temperature relay
Power earth leakage protection, overload protection, short-circuit protection
Storage   Environmental Requirement environmental temperature of the machine keep within 0ºC~+40ºC
        Installation Site
          Requirement
* the distance between the wall and left/right/back should be at least 600mm(A/B)
* the distance between the wall and the front side of the machine should be at least 1200mm(C)
* please make sure the gate, gallery and elevator could pass the machine in case of affect to your company normal working

 

Product Parameters

BGD 897 High-Low Temperature Humidity Cabinet Programmable Constant Temperature Humidity Device
 

 Ordering
     Information
 Temperature
       Range
Humidity   Range Total   Power/Max. Current   Working Room Size
          (W×H×D)
      Overall Size
         (W×H×D)
BGD 897/100B -20~150C 20~98% 4.6KW/16A 400×500×500mm 900×1400×1150mm
BGD 897/100C -40~150C
BGD 897/100D -60~150C
BGD 897/225B -20~150C 5.5KW/22A 500×750×600mm 1000×1650×1250mm
BGD 897/225C -40~150C
BGD 897/225D -60~150C
BGD 897/608B -20~150C 11KW/12A
(380V; 3 phase and 4 wires)
800×950×800mm 1300×1850×1400mm
Temperature Uniformity ± 2 ºC
Humidity Uniformity ≤ 2%~3% RH(>= 75%RH) or ≤±5% RH(≤75% RH)
Temperature Stability ±0.5 ºC
Humidity Stability ±2% RH
Temperature Increasing Rate 3.5ºC/min(no-load, average value during the whole test)
Temperature Decreasing Rate >=1ºC/min(no-load, average value during the whole test)
Power Supply 220V/380V; 50HZ
Total Power 5.5 KW
Detailed Photos

 

BGD 897 High-Low Temperature Humidity Cabinet Programmable Constant Temperature Humidity Device

BGD 897 High-Low Temperature Humidity Cabinet Programmable Constant Temperature Humidity Device

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier