Kgjb-802 Transmitter Calibration Device Universal Relay Tester Secondary Current Injection Kit

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 Year
Still deciding? Get samples of US$ 3000/Piece
Request Sample
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
6
Year of Establishment
2020-01-13
  • Kgjb-802 Transmitter Calibration Device Universal Relay Tester Secondary Current Injection Kit
  • Kgjb-802 Transmitter Calibration Device Universal Relay Tester Secondary Current Injection Kit
  • Kgjb-802 Transmitter Calibration Device Universal Relay Tester Secondary Current Injection Kit
  • Kgjb-802 Transmitter Calibration Device Universal Relay Tester Secondary Current Injection Kit
  • Kgjb-802 Transmitter Calibration Device Universal Relay Tester Secondary Current Injection Kit
  • Kgjb-802 Transmitter Calibration Device Universal Relay Tester Secondary Current Injection Kit
Find Similar Products

Basic Info.

Model NO.
KGJB-802
Maxcapacity
<1000KN
Accuracy Grade
1
Load Way
Electronic Load
Display
Digital
Control
Manual Control
Weight
18
Power Source
AC220V
Transport Package
Plywood Cases
Specification
40*30*18CM
Trademark
LONROY
Origin
Guangdong
HS Code
9024800000
Production Capacity
200

Product Description

KGJB-802 Transmitter Calibration Device Universal Relay Tester Secondary Current Injection Kit

Feature

KGJB-802 microcomputer relay protection tester (three-phase, precision 0.2, industrial computer) refers to the original Ministry of Power issued by the "microcomputer relay protection test device technical conditions" on the basis of careful summary of the development of previous generations of products, production experience, and the use of modern digital technology, high precision electronic devices, microcomputer systems and new lines, new structure developed. It can independently complete the device testing in professional fields such as microcomputer protection, relay protection, excitation, measurement, fault recording, etc., and is widely used in scientific research, production and electrical test sites in electric power, petrochemical, metallurgy, railway, aviation and other industries.

 

KGJB-802 Transmitter Calibration Device Universal Relay Tester Secondary Current Injection Kit

Product Characteristics
1, standard 4 phase voltage 3 phase current output. With 4 phase voltage and 3 phase current output, it is convenient to carry out various combination outputs for various types of protection tests. Each phase voltage can output 120V, current three and can output 120A, the fourth phase voltage Ux is a multi-function voltage item, can be set to 4 kinds of 3U0 or detection voltage, or any voltage value of the case output.
2, single machine operation is convenient. The single machine is operated by the convenient and flexible rotating mouse through the large-screen LCD display, all Chinese display. It can complete most of the field test and verification work, can verify all kinds of relays and microcomputer protection, and can simulate all kinds of complex transient, permanent and transformational faults for whole group tests. Boot can be used, easy to operate.
3, double operation mode. Through the full set of Chinese operating software on the Windows platform, you can carry out a variety of large-scale complex and more automated verification work, you can easily test and scan a variety of protection values, you can store test data in real time, display vector graphs, draw fault waveforms, and print reports online.
4, powerful software. It can complete a variety of large and complex calibration work with high degree of automation, such as three-phase differential test, plant power quick cutting, ready self-feeding test, line protection inspection and reclosing at the same time, etc., can easily test and scan various protection values, fault playback, real-time storage of test data, display vector graphics, online printing reports, etc.
5. Rich switching contacts. 10 contact inputs and 8 air contact outputs. Input contacts are null contacts and 0 ~ 250V potential contacts compatible, intelligent automatic recognition. Input and output contacts can be expanded according to user needs.

6, large screen LCD display. The machine adopts 800×600 dot matrix large screen high-resolution graphic LCD screen, all operation processes are set on the display screen, the operation interface and test results are displayed in Chinese, the display is intuitive and clear.
7. Protect yourself. Adopt reasonable design of heat dissipation structure, and has a variety of reliable and perfect protection measures and power soft start, and a certain fault self-diagnosis and blocking function.
8, with independent dedicated DC power output. The device is equipped with one 110V and 220V special adjustable DC power output.
9, cost-effective. It is a cross-professional joint design product, which integrates the advanced scientific and technological achievements of many professions. Both the performance of a large tester, and the price of a small tester, with a high performance-to-price ratio.

 

KGJB-802 Transmitter Calibration Device Universal Relay Tester Secondary Current Injection Kit

Product Parameters

Ac current output

 

       

Phase current output

 0~40A

Output accuracy: 0.2

Three-phase parallel current output

 0~120A

Phase current long time allowable working value

 10A

Maximum output power of phase current

 420VA

Maximum output power at maximum output of three-phase parallel current

 900VA

Three and the maximum current output allowable working time

 10s

frequency domain

 20~1000Hz

Harmonic frequency

 1~20

Dc current output

current output

 0~±10A/per phase,0~±30A/trigraph

Output accuracy: 0.5 level

Maximum output load voltage

 20V

Ac voltage output

Phase voltage output

 0~120V

Output accuracy: 0.2 level

Line voltage output

 0~240V

Phase voltage/line voltage output power

 80VA/100VA

frequency range

 20~1000Hz

Harmonic frequency

 1~20 times

Dc voltage output

Phase voltage output amplitude

 0~±160V

Output accuracy: 0.5 level

Line voltage output amplitude

 0~±320V

Phase voltage/line voltage output power

 70VA/140VA

on-off input

Channel number

 10 way

input mode

Null contact: 1 ~ 20mA, 24V
Potential contact access: "0" : 0 ~ +6V; 1: +11V to +250V

digital output

Channel number

 8 pairs

output mode

 DC:220V/0.2A;AC:220V/0.5A

time measurement

 0.1ms~9999s

Measurement accuracy: 0.1ms

Size

 400×300×180mm3

Weight

 18kg

Electric source

 AC 220V±10% 50Hz±10% 10A

environment temperature

 -10ºC~+50ºC

Kgjb-802 Transmitter Calibration Device Universal Relay Tester Secondary Current Injection KitKgjb-802 Transmitter Calibration Device Universal Relay Tester Secondary Current Injection Kit

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier