Wired 6 Clamp 6 Differential Protection Loop Vector Analyzer

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 Year
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
6
Year of Establishment
2020-01-13
  • Wired 6 Clamp 6 Differential Protection Loop Vector Analyzer
  • Wired 6 Clamp 6 Differential Protection Loop Vector Analyzer
  • Wired 6 Clamp 6 Differential Protection Loop Vector Analyzer
  • Wired 6 Clamp 6 Differential Protection Loop Vector Analyzer
  • Wired 6 Clamp 6 Differential Protection Loop Vector Analyzer
  • Wired 6 Clamp 6 Differential Protection Loop Vector Analyzer
Find Similar Products

Basic Info.

Model NO.
KDZD566
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Transport Package
Plywood Case
Trademark
LONROY
Origin
China
HS Code
9024800000
Production Capacity
200pieces/Month

Product Description

Wired 6 clamp 6 differential protection loop vector analyzer

The company according to the needs of field testing, timely development of KDZD566 multi-function vector analyzer.
KDZD566 multi-function vector analyzer integrates multiple functions and has a variety of measurement functions, the

main measurement functions are:
Phase meter function - check the correctness of main variable differential protection and busbar differential;
Electrical parameter tester function - test the parameters of the power system;
Metering wire detector function - to detect three-phase three-wire power metering wire inspection;
Harmonic content test function - field test of harmonic content of voltage and current;
Oscilloscope function - Display bar chart, as a simple oscilloscope, used to observe the test signal waveform.
The measuring instrument adopts dsp AC sampling, can measure 3 voltage and 6 current analog at the same time, the instrument 9 channel vector display on the same screen, human-machine dialogue interface is friendly; Independently developed hand-held mold structure, high strength engineering plastic, strong and light, easy to use, greatly convenient for field use, is the power worker's right-hand assistant.

Wired 6 clamp 6 differential protection loop vector analyzer
Functional characteristics
1, three voltage, six current vector on the same screen display, for the differential protection device test only one connection can complete the drawing of the hexagonal diagram, greatly improve the work efficiency; In the case of small space and difficult wiring, the double-clamp method can be used for multiple measurements and finally draw a complete hexagonal diagram.
2, the use of clamp current transformer connection, no need to disconnect the current circuit, safe and convenient.
3, can carry out vector analysis of complex protection devices, judge whether the wiring is correct, and give the correct wiring diagram for comparison.
4, conventional electrical parameters can be tested, while displaying three-phase voltage, three-phase current, three-phase active power, three-phase apparent power, three-phase phase Angle; The voltage amplitude, current amplitude and power value of the primary side of the transformer can be directly read and converted.
5, can carry out three-phase three-wire high-voltage metering device error wiring check, can analyze and judge the three-phase three-wire 48 kinds of wiring, directly give the analysis results; Investigate and punish the means of stealing electricity by maliciously changing the metering connection to effectively avoid the loss of electricity charges.
6, can carry out harmonic analysis of the measured signal on the spot, can analyze the content of 2-21 harmonics, and automatically calculate the total harmonic distortion degree.
7, large screen, high brightness color LCD display, Chinese graphic menu and operation prompts to achieve friendly human-machine dialogue, touch the silicone button to make the operation more comfortable, feel better, wide temperature LCD with brightness adjustment, can adapt to winter and summer seasons.
8, large capacity lithium battery power supply, continuous work up to 8 hours.
9, the user can real-time test data in the form of records saved for centralized management, filing, access, can store more than 200 groups of data.
10. The saved records can be uploaded to the background management computer for comprehensive analysis and review.
11, with perpetual calendar, clock function, real-time display of the date and time of the test work.
12, small size, light weight, easy to use on site.
13, reserve USB interface, available instruments to replace flash disks and other mobile storage devices.

Wired 6 clamp 6 differential protection loop vector analyzer

1. Enter features
Number of voltage channels  3
Voltage measurement range 20~450V
Voltage display resolution 0.01V
Current channels 6 channels
Current measurement range  0~10A
Current display resolution  0.0001A
Phase measurement range -180° ~ +180°
Harmonic analysis times 2 ~ 21 times
2. Accuracy
Voltage  ±0.2%
Current, power ±0.2%
Phase Angle  ±1°
Measurement error of harmonic voltage content ≤ 0.3%
Measurement error of harmonic current content ≤ 0.5%
working temperature -15ºC~ +40ºC
charging power supply AC 160V~260V
insulation

, voltage, current input end of the insulation resistance to the housing ≥100MΩ.

(2) The working power input side is subjected to a power frequency of 2KV (effective value) between the shell, which lasts 1 minute experiment.

 volume 250mm×160mm×60mm
Weight  1.8Kg

 

The company according to the needs of field testing, timely development of KDZD566 multi-function vector analyzer.
KDZD566 multi-function vector analyzer integrates multiple functions and has a variety of measurement functions, the

main measurement functions are:
Phase meter function - check the correctness of main variable differential protection and busbar differential;
Electrical parameter tester function - test the parameters of the power system;
Metering wire detector function - to detect three-phase three-wire power metering wire inspection;
Harmonic content test function - field test of harmonic content of voltage and current;
Oscilloscope function - Display bar chart, as a simple oscilloscope, used to observe the test signal waveform.
The measuring instrument adopts dsp AC sampling, can measure 3 voltage and 6 current analog at the same time, the instrument 9 channel vector display on the same screen, human-machine dialogue interface is friendly; Independently developed hand-held mold structure, high strength engineering plastic, strong and light, easy to use, greatly convenient for field use, is the power worker's right-hand assistant.

vector analyzer
Functional characteristics
1, three voltage, six current vector on the same screen display, for the differential protection device test only one connection can complete the drawing of the hexagonal diagram, greatly improve the work efficiency; In the case of small space and difficult wiring, the double-clamp method can be used for multiple measurements and finally draw a complete hexagonal diagram.
2, the use of clamp current transformer connection, no need to disconnect the current circuit, safe and convenient.
3, can carry out vector analysis of complex protection devices, judge whether the wiring is correct, and give the correct wiring diagram for comparison.
4, conventional electrical parameters can be tested, while displaying three-phase voltage, three-phase current, three-phase active power, three-phase apparent power, three-phase phase Angle; The voltage amplitude, current amplitude and power value of the primary side of the transformer can be directly read and converted.
5, can carry out three-phase three-wire high-voltage metering device error wiring check, can analyze and judge the three-phase three-wire 48 kinds of wiring, directly give the analysis results; Investigate and punish the means of stealing electricity by maliciously changing the metering connection to effectively avoid the loss of electricity charges.
6, can carry out harmonic analysis of the measured signal on the spot, can analyze the content of 2-21 harmonics, and automatically calculate the total harmonic distortion degree.
7, large screen, high brightness color LCD display, Chinese graphic menu and operation prompts to achieve friendly human-machine dialogue, touch the silicone button to make the operation more comfortable, feel better, wide temperature LCD with brightness adjustment, can adapt to winter and summer seasons.
8, large capacity lithium battery power supply, continuous work up to 8 hours.
9, the user can real-time test data in the form of records saved for centralized management, filing, access, can store more than 200 groups of data.
10. The saved records can be uploaded to the background management computer for comprehensive analysis and review.
11, with perpetual calendar, clock function, real-time display of the date and time of the test work.
12, small size, light weight, easy to use on site.
13, reserve USB interface, available instruments to replace flash disks and other mobile storage devices.

vector analyzer

1. Enter features
Number of voltage channels  3
Voltage measurement range 20~450V
Voltage display resolution 0.01V
Current channels 6 channels
Current measurement range  0~10A
Current display resolution  0.0001A
Phase measurement range -180° ~ +180°
Harmonic analysis times 2 ~ 21 times
2. Accuracy
Voltage  ±0.2%
Current, power ±0.2%
Phase Angle  ±1°
Measurement error of harmonic voltage content ≤ 0.3%
Measurement error of harmonic current content ≤ 0.5%
working temperature -15ºC~ +40ºC
charging power supply AC 160V~260V
insulation

, voltage, current input end of the insulation resistance to the housing ≥100MΩ.

(2) The working power input side is subjected to a power frequency of 2KV (effective value) between the shell, which lasts 1 minute experiment.

 volume 250mm×160mm×60mm
Weight  1.8Kg

 

The company according to the needs of field testing, timely development of KDZD566 multi-function vector analyzer.
KDZD566 multi-function vector analyzer integrates multiple functions and has a variety of measurement functions, the

main measurement functions are:
Phase meter function - check the correctness of main variable differential protection and busbar differential;
Electrical parameter tester function - test the parameters of the power system;
Metering wire detector function - to detect three-phase three-wire power metering wire inspection;
Harmonic content test function - field test of harmonic content of voltage and current;
Oscilloscope function - Display bar chart, as a simple oscilloscope, used to observe the test signal waveform.
The measuring instrument adopts dsp AC sampling, can measure 3 voltage and 6 current analog at the same time, the instrument 9 channel vector display on the same screen, human-machine dialogue interface is friendly; Independently developed hand-held mold structure, high strength engineering plastic, strong and light, easy to use, greatly convenient for field use, is the power worker's right-hand assistant.

vector analyzer
Functional characteristics
1, three voltage, six current vector on the same screen display, for the differential protection device test only one connection can complete the drawing of the hexagonal diagram, greatly improve the work efficiency; In the case of small space and difficult wiring, the double-clamp method can be used for multiple measurements and finally draw a complete hexagonal diagram.
2, the use of clamp current transformer connection, no need to disconnect the current circuit, safe and convenient.
3, can carry out vector analysis of complex protection devices, judge whether the wiring is correct, and give the correct wiring diagram for comparison.
4, conventional electrical parameters can be tested, while displaying three-phase voltage, three-phase current, three-phase active power, three-phase apparent power, three-phase phase Angle; The voltage amplitude, current amplitude and power value of the primary side of the transformer can be directly read and converted.
5, can carry out three-phase three-wire high-voltage metering device error wiring check, can analyze and judge the three-phase three-wire 48 kinds of wiring, directly give the analysis results; Investigate and punish the means of stealing electricity by maliciously changing the metering connection to effectively avoid the loss of electricity charges.
6, can carry out harmonic analysis of the measured signal on the spot, can analyze the content of 2-21 harmonics, and automatically calculate the total harmonic distortion degree.
7, large screen, high brightness color LCD display, Chinese graphic menu and operation prompts to achieve friendly human-machine dialogue, touch the silicone button to make the operation more comfortable, feel better, wide temperature LCD with brightness adjustment, can adapt to winter and summer seasons.
8, large capacity lithium battery power supply, continuous work up to 8 hours.
9, the user can real-time test data in the form of records saved for centralized management, filing, access, can store more than 200 groups of data.
10. The saved records can be uploaded to the background management computer for comprehensive analysis and review.
11, with perpetual calendar, clock function, real-time display of the date and time of the test work.
12, small size, light weight, easy to use on site.
13, reserve USB interface, available instruments to replace flash disks and other mobile storage devices.

vector analyzer

1. Enter features
Number of voltage channels  3
Voltage measurement range 20~450V
Voltage display resolution 0.01V
Current channels 6 channels
Current measurement range  0~10A
Current display resolution  0.0001A
Phase measurement range -180° ~ +180°
Harmonic analysis times 2 ~ 21 times
2. Accuracy
Voltage  ±0.2%
Current, power ±0.2%
Phase Angle  ±1°
Measurement error of harmonic voltage content ≤ 0.3%
Measurement error of harmonic current content ≤ 0.5%
working temperature -15ºC~ +40ºC
charging power supply AC 160V~260V
insulation

, voltage, current input end of the insulation resistance to the housing ≥100MΩ.

(2) The working power input side is subjected to a power frequency of 2KV (effective value) between the shell, which lasts 1 minute experiment.

 volume 250mm×160mm×60mm
Weight  1.8Kg

 

The company according to the needs of field testing, timely development of KDZD566 multi-function vector analyzer.
KDZD566 multi-function vector analyzer integrates multiple functions and has a variety of measurement functions, the

main measurement functions are:
Phase meter function - check the correctness of main variable differential protection and busbar differential;
Electrical parameter tester function - test the parameters of the power system;
Metering wire detector function - to detect three-phase three-wire power metering wire inspection;
Harmonic content test function - field test of harmonic content of voltage and current;
Oscilloscope function - Display bar chart, as a simple oscilloscope, used to observe the test signal waveform.
The measuring instrument adopts dsp AC sampling, can measure 3 voltage and 6 current analog at the same time, the instrument 9 channel vector display on the same screen, human-machine dialogue interface is friendly; Independently developed hand-held mold structure, high strength engineering plastic, strong and light, easy to use, greatly convenient for field use, is the power worker's right-hand assistant.

vector analyzer
Functional characteristics
1, three voltage, six current vector on the same screen display, for the differential protection device test only one connection can complete the drawing of the hexagonal diagram, greatly improve the work efficiency; In the case of small space and difficult wiring, the double-clamp method can be used for multiple measurements and finally draw a complete hexagonal diagram.
2, the use of clamp current transformer connection, no need to disconnect the current circuit, safe and convenient.
3, can carry out vector analysis of complex protection devices, judge whether the wiring is correct, and give the correct wiring diagram for comparison.
4, conventional electrical parameters can be tested, while displaying three-phase voltage, three-phase current, three-phase active power, three-phase apparent power, three-phase phase Angle; The voltage amplitude, current amplitude and power value of the primary side of the transformer can be directly read and converted.
5, can carry out three-phase three-wire high-voltage metering device error wiring check, can analyze and judge the three-phase three-wire 48 kinds of wiring, directly give the analysis results; Investigate and punish the means of stealing electricity by maliciously changing the metering connection to effectively avoid the loss of electricity charges.
6, can carry out harmonic analysis of the measured signal on the spot, can analyze the content of 2-21 harmonics, and automatically calculate the total harmonic distortion degree.
7, large screen, high brightness color LCD display, Chinese graphic menu and operation prompts to achieve friendly human-machine dialogue, touch the silicone button to make the operation more comfortable, feel better, wide temperature LCD with brightness adjustment, can adapt to winter and summer seasons.
8, large capacity lithium battery power supply, continuous work up to 8 hours.
9, the user can real-time test data in the form of records saved for centralized management, filing, access, can store more than 200 groups of data.
10. The saved records can be uploaded to the background management computer for comprehensive analysis and review.
11, with perpetual calendar, clock function, real-time display of the date and time of the test work.
12, small size, light weight, easy to use on site.
13, reserve USB interface, available instruments to replace flash disks and other mobile storage devices.

vector analyzer

1. Enter features
Number of voltage channels  3
Voltage measurement range 20~450V
Voltage display resolution 0.01V
Current channels 6 channels
Current measurement range  0~10A
Current display resolution  0.0001A
Phase measurement range -180° ~ +180°
Harmonic analysis times 2 ~ 21 times
2. Accuracy
Voltage  ±0.2%
Current, power ±0.2%
Phase Angle  ±1°
Measurement error of harmonic voltage content ≤ 0.3%
Measurement error of harmonic current content ≤ 0.5%
working temperature -15ºC~ +40ºC
charging power supply AC 160V~260V
insulation

, voltage, current input end of the insulation resistance to the housing ≥100MΩ.

(2) The working power input side is subjected to a power frequency of 2KV (effective value) between the shell, which lasts 1 minute experiment.

 volume 250mm×160mm×60mm
Weight  1.8Kg

Wired 6 Clamp 6 Differential Protection Loop Vector Analyzer
Wired 6 Clamp 6 Differential Protection Loop Vector Analyzer

Wired 6 Clamp 6 Differential Protection Loop Vector AnalyzerWired 6 Clamp 6 Differential Protection Loop Vector AnalyzerWired 6 Clamp 6 Differential Protection Loop Vector AnalyzerWired 6 Clamp 6 Differential Protection Loop Vector Analyzer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier