Optical Contact Angle Tester Contact Angle Goniometer Drop Shape Analyzer

Product Details
Customization: Available
After-sales Service: Online Support
Warranty: 1year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
6
Year of Establishment
2020-01-13
  • Optical Contact Angle Tester Contact Angle Goniometer Drop Shape Analyzer
  • Optical Contact Angle Tester Contact Angle Goniometer Drop Shape Analyzer
  • Optical Contact Angle Tester Contact Angle Goniometer Drop Shape Analyzer
  • Optical Contact Angle Tester Contact Angle Goniometer Drop Shape Analyzer
  • Optical Contact Angle Tester Contact Angle Goniometer Drop Shape Analyzer
  • Optical Contact Angle Tester Contact Angle Goniometer Drop Shape Analyzer
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
LR-SDC-100
Mass Scope of Workpiece
<900kg
Type
Contact Angle Meter
Maxcapacity
<1000KN
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
No
Model
Lr-Sdc-100
Standard
ASTM D724 ASTM D5946 ISO15989
Name
Contact Angle Meter
Optical
220V
Transport Package
Paper Box
Trademark
lonroy
Origin
China
HS Code
9024800000
Production Capacity
200PCS/Month

Packaging & Delivery

Package Size
47.00cm * 62.00cm * 58.00cm
Package Gross Weight
50.000kg

Product Description

Optical Contact Angle tester Contact angle goniometer Drop shape analyzer
 
Product Description

Contact Angle refers to the tangent line of the gas-liquid interface at the intersection point of gas, liquid and solid. This tangent line has an Angle between the liquid and the solid-liquid boundary. The measurement of Contact Angle is the main method of surface performance detection nowadays.
Standard contact Angle measurement instrument is to use the principle of optical imaging, image contour analysis way to measure the surface contact Angle, wettability, interfacial tension of table, surface energy, such as performance, equipment cost-effective, comprehensive functions, and can meet the demand of conventional measurement, has been widely used in many colleges and universities institutes and enterprises.
Application
Contact Angle measuring instrument is widely used in various industries, in the mobile phone manufacturing, glass manufacturing, surface treatment, material research, chemical and chemical industry, semiconductor manufacturing, paint and ink, electronic circuits, textile fiber, medical biological and other fields, contact Angle measurement has become an important instrument to evaluate the surface performance.
(some test functions need to be completed by purchasing special accessories)
1. Wetting behaviors of liquid on solid surface, such as spreading, infiltration and absorption, etc., static contact Angle was measured by droplet method;
2. Measurement of forward Angle, backward Angle, contact Angle lag, rolling Angle and dynamic contact Angle of materials on solid surface;
3. Continuous real-time research and process recording of absorption materials, and curve analysis of contact Angle changes with time;
4. Measurement of contact Angle of various special materials, such as powder, curved surface, superhydrophobic/superhydrophilic samples;
5. Test the contact Angle of the material immersed in the liquid by adhesive drop method;
6. Measurement of interfacial tension, polarity and dispersion components of various liquid surface by droplet method;
7. Calculate the Surface free energy and analyze its polar dispersion component;
8. Analyze the adherent work of liquid on solid surface to evaluate the uniformity and cleanliness of solid surface.
Optical Contact Angle tester Contact angle goniometer Drop shape analyzer
Principle

As shown in the figure above, the contact Angle measuring instrument is mainly composed of five parts: light source, injection unit, sample table, acquisition system and analysis software. The equipment adopts the principle of optical imaging.
Light source adopts dense LED cold light design, uniform light emitting, image cleaning, long life;
The injection unit adopts micro manual knob type liquid injection, with stable drip and high precision;
The sample table adopts 3d manual fine adjustment platform, flexible operation, accurate positioning, the sample table can be customized according to the actual sample size;
The acquisition system adopts the black and white imported CCD camera, which is stable to shoot, with clear and reliable images. The lens is equipped with the German industrial-grade imported configuration, with the magnification adjustable from 0.7 to 4.5 times, and the imaging is free from deformation.
The analysis software has powerful functions, has one-button automatic fitting ability, has the most advanced fitting method in the world, and meets the precise fitting of various droplet forms;
Optical Contact Angle tester Contact angle goniometer Drop shape analyzer
Specifications
Host machine
Outsize 550mm(L)*196mm(W)*485mm(H)
Weight 11KG
Power 220V / 60HZ
Light source system
Light source Dense LED can adjust blue tone industrial grade cold light source
Lifelong The service life is more than 25,000 hours
Injection unit
Injector Dedicated precision syringe capacity 1000μL
Drip Manual rotary injection, drip precision can be achieved 0.2μL
Injection unit movement Up down 100mm;  Left right 100mm
Acquisition system
CCD SONY imported high speed industrial chip with 25 frames /S and 130W pixels
 Lens 0.7-4.5 times hd industrial-grade continuous variable magnification microscope
Acquisition system adjustment Before and after 60 mm, view Angle adjustable (smooth inspect, look down, 360 ° rotating Angle of view, etc)
Sample station installation
Work Table size 120mm*150mm
Maximum sample size 10inch
Maximum sample size Front back move  manual,stroke 60mm,accuracy 0.1mm
Left right move, manual,stroke 35mm,accuracy 0.1mm
Up  down move,   manual,stroke 80mm,accuracy0.1mm
Software
Contact Angle measurement range 0-180°
Accuracy of contact Angle measurement ±0.1°
Analyze software functions 1,China's most advanced contact Angle measurement and analysis software automatic fitting method(One key automatic fitting,There is no manual error
)Include:Circle method,Ellipse/Oblique ellipse,LY,(Differential circle / Differential ellipse);
2,Dynamic contact Angle fitting (batch fitting of multiple images),include Wettability,(Video analysis);
  1. Surface energy;
  2. Adhesion work;
Accord with national standard
1.GB/T 24368-2009(detection of hydrophobic pollutants on glass surface);
2.SY/ t5153-2007 (reservoir rock wettability measurement method);
ASTM D 724-99 (2003) (test method for wettability of paper surfaces);
4.ASTM d5946-2004 (measurement of the contact Angle between plastic film and water);
5.ISO15989 (measurement of water contact Angle of plastic film and thin plate corona treated film);
Optical Contact Angle Tester Contact Angle Goniometer Drop Shape AnalyzerOptical Contact Angle Tester Contact Angle Goniometer Drop Shape AnalyzerOptical Contact Angle Tester Contact Angle Goniometer Drop Shape AnalyzerOptical Contact Angle Tester Contact Angle Goniometer Drop Shape AnalyzerOptical Contact Angle Tester Contact Angle Goniometer Drop Shape AnalyzerOptical Contact Angle Tester Contact Angle Goniometer Drop Shape Analyzer