1. with unique patent super single sensor technology, ensure the accuracy of weighing results, the stability and fast response
2. membrane weighing technology, instant you trace weighing conditions can also obtain the same speed
3. unique temperature compensation scheme
The unique temperature compensation scheme solves the problem of reliability of balance weighing results due to the influence of temperature
4. the VA display, operation is simple, clear reading and directly
Intuitive and clear VA display, the user's operation interface is simple, clear structure
5. adopts isoCAL automatic internal calibration and adjustment function, fully ensure the accuracy of weighing results
Fully automatic temperature and time triggered calibration and adjustment functions ensure that accurate weighing results can be obtained at any time and temperature.
6. unique membrane weighing technology
With the unique filtration membrane weighing technology, accurate results can be obtained quickly, even with the minimum sensible load
7. level 4 shock technology easily meet your all kinds of weighing the environment
You can set different environment parameters based on different weighing environments to achieve accurate and fast weighing in corresponding environments
8. standard communication interface:
Automatic identification printer
Standard RS232, easy to achieve and peripheral connection
Model |
JP1204 |
JP2204 |
JP1204A |
JP2204A |
|
maximum range(Max) |
120g |
220g |
120g |
220g |
|
division value(d) |
0.1mg |
||||
Repeatability (typical error) (5% load) |
0.2mg |
||||
Repeatability (typical error) (Close to 100% load) |
0.3mg |
||||
Linear error (Typical error) |
0.3mg |
||||
Calibration |
External weight calibration |
Fully automatic internal calibration |
|||
sensitivity drift (+10ºC~+30ºC) |
5ppm/k |
||||
operating temperature range (OTR) |
10ºC~30ºC |
||||
Operating humidity range |
20%-85% Relative (non-condensing) |
||||
Typical stability time |
3 second |
||||
Pan size |
Φ90mm |
||||
boundary dimension |
210mm×310mm×315mm |
||||
Height of weighing room |
210mm |
||||
Temperature compensating fluctuation |
≤1ºC/time |
||||
working power supply |
100V -240VAC frequency 50/60HZ;electricity :MAX0.45A |
||||
Baud rate |
300,600,1200,2400,4800,9600 |
||||
expertise rating |
2 level |