JK5530 Battery Integrated Tester/Battery Internal Resistance Testing Machine JK5530B JK5530C
The common rechargeable batteries include lithium batteries, nickel cadmium batteries, nickel hydrogen batteries, and sealed lead-acid batteries. Among them, lithium battery has the characteristics of large capacity, light weight and high cycle times. It is widely used in mobile phones, PDA, digital cameras, camcorders, notebook computers and other fields.Is currently the most advanced rechargeable battery, referred to here is the finished lithium battery lithium battery pack by lithium batteries (lithium ion batteries or Li polymer batteries) and lithium battery protection board. Nickel cadmium battery is a relatively early application of rechargeable battery. It has the characteristics of low cost, low internal resistance and high current discharge. So far, it has been widely applied in some electric tools and electric cars.
Similar NiMH battery and nickel cadmium battery, but because they do not contain heavy metals, so the environmental pollution is small, at present in some common consumer electronic products have been widely applied in fields of application, has replaced the previous nickel cadmium batteries. Small sealed lead-acid battery, also known as maintenance free lead-acid electric he, at present mature technology, mainly used in fixed backup power applications, such as uninterruptible power supply, emergency lighting and so on.
JK5530 Battery Integrated Tester/Battery Internal Resistance Testing Machine JK5530B JK5530C
Technical parameter
Model | JK5530 | JK5530B | ||||
Measuring range | Range of battery voltage measurement | 0-36V,Minimum resolution 10mV,accuracy:±30mV | 0-60V,Minimum resolution 10mV,accuracy:±5mV | |||
Range of internal resistance measurement | 0-999mΩ,Minimum resolution 1mΩ | 0-1999mΩ,Minimum resolution 1mΩ | ||||
Capacity measurement range | 0-10000mAH,Minimum resolution 1mAH | |||||
Measurement accuracy | Accuracy of voltage measurement |
±(result *0.1%+3mV)(voltage0~36V) ±(result*0.1%+30mV)(voltage37~62V) |
||||
Accuracy of current measurement |
±(result *0.2%+30mA)(current 0~10A) ±(result *0.5%+30mA)(current 11~30A) |
|||||
Accuracy of internal resistance measurement | ±(result *1%+1mΩ) | |||||
Accuracy of battery capacity measurement | 10AH :±5% | 100AH :±5% | ||||
Test speed | Static test (test all functions) | 1.1-2 seconds | ||||
Capacity test (1C current charge and discharge) | 3-4 hours | |||||
Internal numerical control voltage source index | Maximum output voltage | 16V | 62V | |||
Maximum output current | 5A | |||||
Maximum output power | 80W | 200W | ||||
Ripple voltage | <20mV | <100mV | ||||
Load adjustment rate | <10% | |||||
response time | 1S | |||||
Internal numerical control electronic load index | Ceiling voltage | 60V | 80V | |||
Maximum discharge current | 10A (continuity),15A(10 second) | 30A(continuity) 40A(2 second),60A( Need to be customized) | ||||
Limit power | 50W(continuity),80W(10 second) | 200W (continuity) | ||||
supply voltage | 220V±10%50Hz | |||||
U disk storage | no | yes | ||||
communication interface | no | yes(with Host computer software) | ||||
Accessories | Kelvin clip test line, test probe | |||||
Size and weight |
Upper frame size (mm):215(w)*88(H)*375(D) Shape size (mm):235(w)*105(H) *430(D), about 3.6kg |