The analyzer refers to ISO9277, ISO15901 and GB-119587 standards, according to the principle of static volumetric measurement, through the mass balance equation, static gas balance and pressure measurement to test the desorption process, the test process is carried out at the temperature of liquid nitrogen. When a known amount of gas is filled into the sample tube, the pressure will drop, and the molar mass of the adsorbed gas at adsorption equilibrium is calculated. The BET surface area and Langmuir specific surface area of single and multi-point samples were calculated by using the theoretical model. The distribution of pore volume, area and total pore volume in BJH; T -- plot micropore volume and surface area, Dubinin-Astakhov micropore distribution, Horvath -- Kawazoe micropore distribution; Density function theory (DFT) and Monte Carlo (MC) aperture distribution model, etc.
Aperture Distribution Model Automatic Specific Surface Area and Porosity Analyzer Tester
Product Features
1. Modular air path design: the introduction of the design concept, the use of modular stainless steel real air path design and anti-leakage measures, so as to ensure the realization of high vacuum, avoid the abuse of too much easy leakage due to the connection of pipeline joints.
2.Constant temperature: Because of its internal structure design, the self-developed metal dewar can store liquid nitrogen for more than ten days, and there is almost no loss of liquid nitrogen during the experiment, so as to ensure the constant temperature of the tested sample, and avoid the defects of fragile and unmovable glass dewar.
3.Sensors: multiple sensors and 22 bit AD conversion devices, to ensure the precision of the surface area and aperture calculation.
4.Its density function theory (DFT) and Monte Carlo (MC) pore size distribution model have established the leading position in the specific surface area and porosity analyzer industry in China, and are also at a high level in the world.
5. Operation automation: the process of adsorption and desorption is controlled by computer without manual operation.
Aperture Distribution Model Automatic Specific Surface Area and Porosity Analyzer Tester
Technical Features
1. BET surface area of single point and multi-point, Langmuir specific surface area
2. Volume and area distribution of pore and macropore in BJH, total pore volume
3,.T-plot micropore volume and surface area, Dubinin-Astakhov micropore distribution, Horvath -- Kawazoe micropore distribution
4. Density function theory (DFT) and Monte Carlo (MC) aperture distribution model
[Output report]
Direct print and EXCEL output of adsorption and desorption isotherms, BET surface area, Langmuir surface area, T-plot micropore volume, BJH pore volume, pore area, total pore volume, total pore area, DBinin-Astakhov, Horvath-KawaZoe micropore distribution, NLDFT/GCMC pore distribution, Review report.
[ Scope of Application ]
Research AND PRODUCT TESTING OF VARIOUS materials, including measurement of ZEolite, MOLECULAR sieve, silica, alumina, soil, clay, catalyst, organomeTALlic compound skeleton structure and other materials.
Aperture Distribution Model Automatic Specific Surface Area and Porosity Analyzer Tester
Technical parameters
|
WBL-810 |
WBL-820 |
WBL-830 |
Specific surface area |
0.01m2/g to no upper limit |
0.01m2/g to no upper limit |
0.01m2/g to no upper limit |
Aperture analysis range |
3.5 to 5000 |
3.5 to 5000 |
3.5 to 5000 |
Test principle |
Physical adsorption of nitrogen at Low temperature (Static capacity method) |
Physical adsorption of nitrogen at Low temperature (Static capacity method) |
Physical adsorption of nitrogen at Low temperature (Static capacity method) |
Adsorption gas |
nitrogen |
nitrogen |
nitrogen |
P/P0 range |
1 x 10-6-0.995 |
1 x 10-6-0.995 |
1 x 10-6-0.995 |
Pressure, Temperature measurement |
Imported pressure sensor 0-133kpa, accuracy 0.12%, 3 temperature sensors: PT-100, accuracy 0.1ºC 1 |
Imported pressure sensor 0-133kpa, accuracy 0.12%, 3 temperature sensors: PT-100, accuracy 0.1ºC 1 |
Imported pressure sensor 0-133kpa, accuracy 0.12%, 3 temperature sensors: PT-100, accuracy 0.1ºC 1 |
dewar |
2L, duration 80 hours |
2L, duration 80 hours |
2L, duration 80 hours |
Vacuum pump |
Mechanical pump |
Mechanical pump |
Mechanical pump |
Limiting vacuum degree |
1.0 x 10-4 torr |
1.0 x 10-4 torr |
1.0 x 10-4 torr |
Measuring software |
Determination of adsorption/desorption isotherms |
Determination of adsorption/desorption isotherms |
Determination of adsorption/desorption isotherms |
Physical parameters |
700 X 700 X 800mm |
700 X 700 X 800mm |
700 X 700 X 800mm |
Processing power
|
At the same time, 1 sample was determined The number of processed samples was 3
|
At the same time, 2 sample was determined The number of processed samples was 3
|
At the same time, 3 sample was determined The number of processed samples was 3
|