Customization: | Available |
---|---|
After-sales Service: | Online |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 3000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical specification |
|
1 Product performance |
|
1.1 Item 1.2. Model 1.3.Volume 1.4 Inner size 1.5 External size 1.5 Weight 1.6 Power supply 1.7 Power |
Ozone aging test chamber (Dynamic) LR-B013 150L W500 X H600 x D500mm W1050 X H1700 x D1100mm 300kg AC380±5%V /50±0.5Hz 4.0KW |
1.7 Function |
Ozone in the atmosphere is very little, while it's a major factor in rubber cracking, the product simulate and enhance atmospheric ozone condition to study the role of ozone on the rubber, and to rapid identificate and evaluate rubber resistance for ozone aging and anti-ozone agent protection. According to"GB / T7762-2003 Test Method for Static Tensile Test of Ozone Resistance Cured Rubber or Thermoplastic Rubber","GB / T2951.21-2008 General Test Method for Insulation and Sheathing Material of Cable","GB / T 11206-2009 Rubber Aging test surface cracking method", and other relevant standards of the test method. |
1.8 Principle and method |
According to test methods and standards, test method can be divided into "static" and "dynamic", the static means the sample is tested in the chamber after stretched well, the dynamic means the sample is installed in the clamp in the chamber, it's tested while being stretched, (It conforms to the standard IEC 60811-403 and do the test for silica gel, cable and other soft-tube test requirements, the rigid wire material directly with the ozone contact aging), the floating of tensile is about 5% - 45% of the sample itself. |
2 Main technical parameters |
|
Temperature range: RT+10ºC~60ºC (Adjustable, ozone will decompose when temp. above 60 ºC) Temperature fluctuation: ±0.5ºC Accuracy of Tem. Distribution: ±2.0ºC Max. Tep. of Ozone: 60ºC (When the temperature is above 60 ºC, ozone decomposition rate will get rapid self-decomposition. Heating time: around 20min from RT to 60 ºC Humidity range: ±3.0%. Humidity fluctuation: ±2.0%. Ozone concentration accuracy: 50~1000pphm (adjustable, low viscosity) Air flow amount: 20~70L/min Air flow rate: 12~16mm/s Revolving speed of sample holder Ozone Accuracy: ±5.0% F.S Ozone fluctuation: ±2.5pphm Specimen fixture: one set of three groups of experimental static fixture |
|
Rubber Ozone Gas Generator Aging Colorfastness Test Chamber Plastic Ozone Resistant Aging Test Machine
3 Structural characteristics |
|
3.1 Structure |
All-in-one machine |
3.2 Material |
a) Inner chamber: SUS304 stainless steel plate b) External chamber: SUS304 stainless steel plate or baking finish. c) Insulation: rigid polyurethane foam + aluminum insulation cotton with double protection. |
3.3 Machine door |
a) Single door, open from left. b) Window frame / door frame with two silicone rubber seal and anti-condensation heating device. c) With observation window (W220xH250mm), lights above the window and door. |
3.4 Requirements for sample holder (for dynamic-type only) |
a) At both ends of the sample to be fixed with a clamp under the required elongation, the longitudinal direction of the specimen shall be substantially parallel to the direction of air flow when in contact with ozonized air.
b) Clamps shall be made of a material (eg aluminum) which does not readily decompose ozone. c) Allow the sample to rotate at a speed between (20 ^ -25) mm / s, in a plane perpendicular to the dry gas flow, with each sample moving continuously along the same path. d) The time of one revolution of the same specimen is (8 ^ -12) min. The scanning area of the specimen shall be at least 40% of the effective area of the test chamber. e) Specimen preparation shall conform to the provisions of GB / T 9865.1. The test specimen is preferably cut from the new test piece and, if desired, may be cut from the finished product. At least 3 specimens shall be required for per test condition. The standard length of the specimen is not less than 10mm, and thickness not less than 0.2mm. The length of specimen between the two ends of the clamp before drawing is not less than 40mm. |
3.5 Control panel |
a) Controller display b) Power switch c) Fault alarm d) Wavelength switch e) light switch button |
3.6 Enclosure configuration |
a) With a stainless steel SUS # 304 shelf turntable b) One φ50mm lead hole:, and with a hole cover and silicone rubber plug. c) Move casters 4 pcs d) Horizontal mounting brackets 4 pcs e) There is a drainage hole in the back of the machine to facilitate the drainage of condensate; (8mm in diameter) f) Three-phase five-wire cable (four-core cable + protective grounding wire) 1 pc, (three meters long). |
4 Air circulation regulation |
|
4.1 Adjustment mode
4.2 Circulation fan |
FLOW THROW air supply; horizontal diffusion vertical heat exchange in arc cycle. Power-saving motor + stainless steel extended axial multi-centrifugal circulation fan.
|
5 Heating system |
|
5.1 Heater
5.2 Control method |
Fin - type heat pipe, stainless steel electric heater for heating.
PID regulation is implemented with solid state relay. |
6 Refrigeration system |
|
6.1. Working mode 6.2. Control mode 6.3. Compressor 6.4. Evaporator 6.5. Condenser 6.6. Expansion system 6.7 Refrigerants 6.8. Refrigeration technology
6.9. Refrigerating accessories
6.10. Accessories |
Imported French Tecumseh fully enclosed compressor / air-cooled.
The controller of the control system automatically adjusts the operating conditions of the refrigerator according to the test conditions. Europe and the United States well-known brands, low-temperature full-compact compressor. (France; Tecumseh ) Finned multi - stage automatic load capacity adjustment. (Japan; Saginomiya) Air cooled condenser. (Japan; Shuangling)
Refrigeration system with capacity automatic control. Environmental protection refrigerant R404 (ozone depletion index is 0). (DuPont, USA)
Nitrogen protection welding, two-stage rotary vane pump vacuum, to ensure that the internal cooling system is clean, and the bottom of compressor designed with water tray, drain the condensate water through the rear row of the machine to the outside. a) Expansion valve (Denmark; DANFOSS) b) Solenoid valve (Japan; Omron) c) Filter (Denmark; DANFOSS) d) Pressure controller (Denmark; DANFOSS) e) Shut-off valves (Italy; CASTEL) f) Oil separator (Europe and the United States; ALCO) With desiccant, oil separator, refrigerant flow window, repair valve, high voltage protection switch. |