  • LS-9916 Flame graphite furnace AAS atomic absorption spectrophotometer
  • LS-9916 Flame graphite furnace AAS atomic absorption spectrophotometer
  • LS-9916 Flame graphite furnace AAS atomic absorption spectrophotometer
  • LS-9916 Flame graphite furnace AAS atomic absorption spectrophotometer
  • LS-9916 Flame graphite furnace AAS atomic absorption spectrophotometer
  • LS-9916 Flame graphite furnace AAS atomic absorption spectrophotometer
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
LS-9916
Ambient temperature
10 ~ 30ºC
Working humidity
≤80%
Wavelength repeatability
<0.05nm
Power
220V±22V,50Hz±1Hz,5KW
Transport Package
Plywood
Specification
/
Trademark
LANGSHUO
Origin
Changsha
HS Code
9024800000
Production Capacity
200

Product Description

LS-9916 Flame graphite furnace AAS atomic absorption spectrophotometer

Product Description
 Instrument description

LS-9916 Flame graphite furnace integrated atomic absorption spectrometer is a fully automatic intelligent flame graphite furnace integrated atomic absorption instrument developed by the company with many years of research and development experience, used to determine the amount of major, trace, trace metal elements and semi-metallic elements in various substances. The machine adopts PC and Chinese interface operating software, making the instrument easy to operate, intuitive and easy to understand. By using advanced electronic circuit system and USB3.0 communication control, the automatic adjustment of wavelength scanning, peak searching, spectral passband width, rotating element lamp frame, atomizer height and position, gas flow, lamp current and photomultiplier negative high voltage is realized. The instrument stores reference conditions for analysis of all the measured elements of a variety of analytical methods, and users can modify the operating conditions according to needs, and can save the operating conditions and working curves and test results, which can be used and processed again.
Performance characteristics
· Integrated design
Using series optical path design, the position of flame graphite furnace atomizer is fixed, the software automatically switches, without hardware replacement, one-second switching, avoiding the error caused by mechanical switching, improving the stability and maintainability of the instrument.
· C-T monochromator
The optical splitting system with 1800 lines /mm and 230nm flash wavelength is adopted.
· Eight element light beacon
One lamp work, up to seven lamps can be preheated, saving the lamp change and preheating time, making the element measurement faster and more convenient.
· USB3.0 communication mode

The industry takes the lead in adopting 3.0 communication interface, which improves communication speed and is compatible with the latest computer Windows 10 system.
· Independent intellectual property rights
With relevant patent certificates and software copyright certificates, user-friendly operation interface, so that your operation is easy, you can switch Chinese and English Windows style
Software interface, can run perfectly under Windows 7, Windows 10 and other operating systems, automatic qualitative and quantitative analysis, automatic calculation of element content, automatic generate test reports.
· Background correction system
Element lamp and deute rium lamp double switching and background deduction, with deute rium lamp and self-absorption two background correction modes, background signal 1A, buckle the background capacity more than 60 times.
· Fully automated design
In addition to the host power switch, all the functions of the instrument are monitored and controlled by the computer, and the software automatically determines the best test conditions for each element.
· Total reflection achromatic optical system
Using concave mirror instead of convex lens as the optical focusing device of the instrument, the color difference problem of different elements is effectively solved, and the efficiency of the optical system is improved.
Flame system
1.Pure titanium atomization chamber, pure titanium combustion head
Effectively prevent acid gas corrosion, longer service life.

  1. Do not install the instrument directly near the window or door to avoid convection, dust, corrosive gases and vibration.
  2. The instrument should be placed on a stable workbench without vibration. There should be an exhaust system above the instrument. There should be no direct light and strong electromagnetic field interference near the instrument, and there should be no strong corrosive gas in the environment.
  3. Keep away from strong electromagnetic field.
  4. Ambient temperature: 10 ~ 30ºC.
  5. Working humidity: ≤80%.
Graphite furnace system
1.Integrated design
The graphite furnace power supply and atomic absorption host are located in one instrument, which shorens the cable length, reduces the electromagnetic interference of the graphite furnace power supply to the outside world, and improves the graphite
Tube heating efficiency.
2.Graphite furnace temperature control precision is high, heating speed is fast
Using high-power transformer, micro-resistance cable and light temperature control, and with software and hardware temperature correction system, the temperature control accuracy of high temperature section can reach ±1%.
More safety protection measures to make sample analysis more safe and reliable
1) Cooling water flow monitoring 2) Carrier gas pressure alarm monitoring 3) graphite tube temperature alarm monitoring 4) graphite furnace temperature alarm monitoring
3.Automatic carrier gas flow control
The gas in the graphite furnace and the gas outside are all automatically controlled by the computer according to the software heating process.
4.150 bit rotary disk graphite furnace automatic sampler
The polar coordinate rotary disk type graphite furnace automatic sampler can realize that flame and graphite furnace share one automatic sampler, high positioning accuracy, stable and reliable operation, and use dimension
Protect your convenience.
LS-9916 Flame graphite furnace AAS atomic absorption spectrophotometer
Product Parameters
Technical index
Whole machine
Monochromator type: Czerny-Turner Wavelength range: 190nm~900nm
Wavelength accuracy: ±0.2nm Wavelength repeatability: <0.05nm
Spectral bandwidth: 0.1/0.2/0.4/0.7/1.4nm five speed automatic switching

flame system
Precision: <0.8%(flame method for copper) static stability: 0.003Abs (static)
Detection limit: <0.008ug/mL dynamic stability: 0.004Abs (dynamic)
Characteristic concentration: <0.025μg/ml/1%(flame method for copper)
Detailed Photos

LS-9916 Flame graphite furnace AAS atomic absorption spectrophotometer

LS-9916 Flame graphite furnace AAS atomic absorption spectrophotometer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier