High Voltage Frequency Conversion/Different Frequency Anti-Interference Dielectric Loss Tester

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 Year
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
6
Year of Establishment
2020-01-13
  • High Voltage Frequency Conversion/Different Frequency Anti-Interference Dielectric Loss Tester
  • High Voltage Frequency Conversion/Different Frequency Anti-Interference Dielectric Loss Tester
  • High Voltage Frequency Conversion/Different Frequency Anti-Interference Dielectric Loss Tester
  • High Voltage Frequency Conversion/Different Frequency Anti-Interference Dielectric Loss Tester
  • High Voltage Frequency Conversion/Different Frequency Anti-Interference Dielectric Loss Tester
  • High Voltage Frequency Conversion/Different Frequency Anti-Interference Dielectric Loss Tester
Find Similar Products

Basic Info.

Model NO.
KD600B
Type
Dielectric Loss Tester
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Transport Package
Plywood Case
Trademark
LONROY
Origin
China
HS Code
9024800000
Production Capacity
200pieces/Month

Product Description

High voltage Frequency conversion/Different frequency anti-interference dielectric loss tester

KD600B dielectric loss tester is a high-precision instrument that can automatically measure the dielectric loss tangent value and capacitance of various high-voltage power equipment in power plants and substations.

Performance characteristics
1. With CVT self-excitation test, one-time wiring, while measuring C1, C2 capacitance and tgδ.
2. The maximum output voltage is 10kV, the maximum output current is 200mA, and the input current of the high-voltage dielectric loss test is increased to 5A.
3. With low voltage shielding function of reverse wiring, C11 can be measured 10kV reverse wiring dielectric loss without removing the wire when the CVT bus is grounded.
4. With positive/reverse wiring, internal/external standard capacitance, internal/external high voltage, various working modes, can do a variety of conventional dielectric loss tests, without external auxiliary equipment.
5. It has the measurement function of external voltage and external CN.
6. The instrument has high measurement accuracy and can meet the requirements of oil dielectric loss measurement, so it only needs to be equipped with standard oil cups and special test lines to achieve oil dielectric loss measurement.
7. Using frequency conversion technology to eliminate 50Hz power frequency interference on site, reliable data can be measured even in the environment of strong electromagnetic interference.
8. Grounding protection function, when the instrument is not grounded or poorly grounded, the instrument does not enter the normal procedure and does not output high voltage.
9. With over current, over voltage and ground protection and other multi-level protection, safe and reliable in the test short circuit or breakdown of the instrument is not damaged.
10. Can automatically distinguish capacitance, inductance, resistance type test.
11. Automatically identify the 50Hz / 60Hz system power supply.
12. Double power input with 110V/220V automatic identification can be provided to facilitate the use of foreign aid projects.
13. Automatically identify the external high-voltage power supply frequency 40Hz ~ 70Hz, allowing the use of power frequency power supply or series resonant power supply to do large-capacity high-voltage dielectric loss test.
14. With frequency conversion CVT self-excitation measurement interface, you can set high voltage/current, low voltage/current 4 protection limits to ensure personal and equipment safety.
15.CVT self-excitation measurement, C1/C2 can be measured at the same time, automatically compensate the busbar grounding and standard capacitor voltage distribution impact, no need to change the line and external accessories.
16. With CVT variable ratio measurement function. CVT ratio, polarity and phase errors can be measured.
17. The wiring contact is poor, the instrument has a prompt function, which is convenient for users to judge the measurement results and check the wiring error.
18. With thermal printer can print out, convenient for users to produce test reports.
19. With calendar clock, can store 100 groups of measurement data.
20. Standard capacitance and high voltage power supply are included to facilitate field testing and reduce field wiring.
21. The instrument adopts large-screen LCD LCD display, and the test process is prompted by the Chinese graphic menu.

High voltage Frequency conversion/Different frequency anti-interference dielectric loss tester

Accuracy

Cx: ±(reading ×1%+1pF)

Tgδ

±(reading ×1%+0.00040)

Anti-interference index

frequency conversion anti-interference, the above accuracy can still be achieved under 200% interference

Capacitance range

Internal high voltage: 3pF ~ 60000pF/10kV

Applied high voltage

3pF ~ 1.5μF/10kV 3pF ~ 1.5μF/10kV

Resolution

up to 0.001pF,4 significant digits

CVT ratio measurement

35 ~ 500kV grade CVT device ratio

Variable ratio measurement range: 10~99999

Variable ratio measurement accuracy: ± reading x1%

Phase measurement range: 0~359.999°

Phase measurement accuracy: ±0.002°

CVT self-excitation method

 low voltage output: output voltage 3 ~ 50V

 

Output current 3 ~ 30A

tgδ range

unlimited, capacitance, inductance, resistance three kinds of test automatic identification

Resolution: 0.001%

Test current range

10μA ~ 5A

Internal high voltage: Set voltage range: 0.5 ~ 10kV

Maximum output current: 200mA

Lifting pressure mode: continuous smooth adjustment

Voltage accuracy :±(1.5%× reading +10V)

Voltage resolution: 1V

External application of high voltage: the maximum test current 1A when the normal connection

Power frequency or frequency conversion 40 ~ 70Hz

Maximum test current during reverse wiring: 1A/10kV

Power frequency or frequency conversion 40 ~ 70Hz

Test frequency: 45Hz, 50Hz, 55Hz, 60Hz, 65Hz single frequency

45/55Hz, 55/65Hz, 47.5/52.5Hz automatic double frequency conversion

Frequency accuracy: ±0.01Hz

 Measurement time

about 40s, related to the measurement method

Input power

180V ~ 270VAC, 50Hz/60Hz±1%, mains or generator power supply

Ambient humidity

-10 ° C to 50 ° C

 Relative humidity

 Relative humidity

 

KD600B dielectric loss tester is a high-precision instrument that can automatically measure the dielectric loss tangent value and capacitance of various high-voltage power equipment in power plants and substations.

Performance characteristics
1. With CVT self-excitation test, one-time wiring, while measuring C1, C2 capacitance and tgδ.
2. The maximum output voltage is 10kV, the maximum output current is 200mA, and the input current of the high-voltage dielectric loss test is increased to 5A.
3. With low voltage shielding function of reverse wiring, C11 can be measured 10kV reverse wiring dielectric loss without removing the wire when the CVT bus is grounded.
4. With positive/reverse wiring, internal/external standard capacitance, internal/external high voltage, various working modes, can do a variety of conventional dielectric loss tests, without external auxiliary equipment.
5. It has the measurement function of external voltage and external CN.
6. The instrument has high measurement accuracy and can meet the requirements of oil dielectric loss measurement, so it only needs to be equipped with standard oil cups and special test lines to achieve oil dielectric loss measurement.
7. Using frequency conversion technology to eliminate 50Hz power frequency interference on site, reliable data can be measured even in the environment of strong electromagnetic interference.
8. Grounding protection function, when the instrument is not grounded or poorly grounded, the instrument does not enter the normal procedure and does not output high voltage.
9. With over current, over voltage and ground protection and other multi-level protection, safe and reliable in the test short circuit or breakdown of the instrument is not damaged.
10. Can automatically distinguish capacitance, inductance, resistance type test.
11. Automatically identify the 50Hz / 60Hz system power supply.
12. Double power input with 110V/220V automatic identification can be provided to facilitate the use of foreign aid projects.
13. Automatically identify the external high-voltage power supply frequency 40Hz ~ 70Hz, allowing the use of power frequency power supply or series resonant power supply to do large-capacity high-voltage dielectric loss test.
14. With frequency conversion CVT self-excitation measurement interface, you can set high voltage/current, low voltage/current 4 protection limits to ensure personal and equipment safety.
15.CVT self-excitation measurement, C1/C2 can be measured at the same time, automatically compensate the busbar grounding and standard capacitor voltage distribution impact, no need to change the line and external accessories.
16. With CVT variable ratio measurement function. CVT ratio, polarity and phase errors can be measured.
17. The wiring contact is poor, the instrument has a prompt function, which is convenient for users to judge the measurement results and check the wiring error.
18. With thermal printer can print out, convenient for users to produce test reports.
19. With calendar clock, can store 100 groups of measurement data.
20. Standard capacitance and high voltage power supply are included to facilitate field testing and reduce field wiring.
21. The instrument adopts large-screen LCD LCD display, and the test process is prompted by the Chinese graphic menu.

dielectric loss tester

Accuracy

Cx: ±(reading ×1%+1pF)

Tgδ

±(reading ×1%+0.00040)

Anti-interference index

frequency conversion anti-interference, the above accuracy can still be achieved under 200% interference

Capacitance range

Internal high voltage: 3pF ~ 60000pF/10kV

Applied high voltage

3pF ~ 1.5μF/10kV 3pF ~ 1.5μF/10kV

Resolution

up to 0.001pF,4 significant digits

CVT ratio measurement

35 ~ 500kV grade CVT device ratio

Variable ratio measurement range: 10~99999

Variable ratio measurement accuracy: ± reading x1%

Phase measurement range: 0~359.999°

Phase measurement accuracy: ±0.002°

CVT self-excitation method

 low voltage output: output voltage 3 ~ 50V

 

Output current 3 ~ 30A

tgδ range

unlimited, capacitance, inductance, resistance three kinds of test automatic identification

Resolution: 0.001%

Test current range

10μA ~ 5A

Internal high voltage: Set voltage range: 0.5 ~ 10kV

Maximum output current: 200mA

Lifting pressure mode: continuous smooth adjustment

Voltage accuracy :±(1.5%× reading +10V)

Voltage resolution: 1V

External application of high voltage: the maximum test current 1A when the normal connection

Power frequency or frequency conversion 40 ~ 70Hz

Maximum test current during reverse wiring: 1A/10kV

Power frequency or frequency conversion 40 ~ 70Hz

Test frequency: 45Hz, 50Hz, 55Hz, 60Hz, 65Hz single frequency

45/55Hz, 55/65Hz, 47.5/52.5Hz automatic double frequency conversion

Frequency accuracy: ±0.01Hz

 Measurement time

about 40s, related to the measurement method

Input power

180V ~ 270VAC, 50Hz/60Hz±1%, mains or generator power supply

Ambient humidity

-10 ° C to 50 ° C

 Relative humidity

 Relative humidity


High Voltage Frequency Conversion/Different Frequency Anti-Interference Dielectric Loss TesterHigh Voltage Frequency Conversion/Different Frequency Anti-Interference Dielectric Loss TesterHigh Voltage Frequency Conversion/Different Frequency Anti-Interference Dielectric Loss TesterHigh Voltage Frequency Conversion/Different Frequency Anti-Interference Dielectric Loss TesterHigh Voltage Frequency Conversion/Different Frequency Anti-Interference Dielectric Loss TesterHigh Voltage Frequency Conversion/Different Frequency Anti-Interference Dielectric Loss Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier