10kv-35kv Insulated Lever Whole Insulated Non-Partial Discharge Withstand Voltage Test Electrode Test Device Tester

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 Year
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
6
Year of Establishment
2020-01-13
  • 10kv-35kv Insulated Lever Whole Insulated Non-Partial Discharge Withstand Voltage Test Electrode Test Device Tester
  • 10kv-35kv Insulated Lever Whole Insulated Non-Partial Discharge Withstand Voltage Test Electrode Test Device Tester
  • 10kv-35kv Insulated Lever Whole Insulated Non-Partial Discharge Withstand Voltage Test Electrode Test Device Tester
  • 10kv-35kv Insulated Lever Whole Insulated Non-Partial Discharge Withstand Voltage Test Electrode Test Device Tester
  • 10kv-35kv Insulated Lever Whole Insulated Non-Partial Discharge Withstand Voltage Test Electrode Test Device Tester
  • 10kv-35kv Insulated Lever Whole Insulated Non-Partial Discharge Withstand Voltage Test Electrode Test Device Tester
Find Similar Products

Basic Info.

Model NO.
KDJF-2002
Type
Withstand Voltage Tester
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Transport Package
Plywood Case
Trademark
LONROY
Origin
China
HS Code
9024800000
Production Capacity
200pieces/Month

Product Description

10kV-35kV insulated lever whole insulated non-partial discharge withstand voltage test electrode test device tester

The high voltage test platform is mainly used for the overall power frequency voltage withstand test of insulation tools such as 35kV and below insulation rods. The test system is composed of main control test bench, inflatable test transformer, booster, metal protection resistor and other booster equipment, and high voltage test bracket.

The insulated rod pressure support adopts a circular structure to save space, and can be tested with 8 insulated rods at a time. The upper pressure balancing ring can be electrically moved up and down to adjust the test length.

 

10kV-35kV insulated lever whole insulated non-partial discharge withstand voltage test electrode test device tester
Functional characteristics

1. It is suitable for the whole insulation withstand voltage test of the insulation rod from 10kV to 35kV.

2. The lifting platform uses glass fiber and epoxy resin as the main materials and pultrusion molding, bending resistance, anti-distortion deformation in line with national standards.

3. The lifting platform structure has uniform and reasonable force, and the overall connection is reliable and stable; Table height 3 meters, the maximum lifting height (including pressure balancing ring) : 6 meters; And can freely adjust the height of lifting.

4. The bottom of the platform is equipped with four adjustable level feet and an anti-overturning device. 5. The high voltage electrode and grounding electrode are ma

de of aluminum pressure balancing ring, which has the characteristics of light weight and high strength.

6. The distance between the insulated rod fixture is not less than 0.5 meters, and the pressure test of 8 insulated rods can be carried out at the same time. The top has a fixed pressure balancing ring with a diameter of 1.6 meters and the base is connected with a high-quality epoxy glass drawbar to form a fixed frame.

7. The ground ring with a diameter of 1.6 meters is dragged by the motor through the middle screw and can be moved up and down on the frame to adjust the test length.

8. The lower part of the insulation rod has a grounding electrode ring with a width of 50mm, which is convenient for the test product to ground.

9. The test length is controlled by the button or remote control, with fast and slow speed, easy to accurately adjust the pressure length.

 
10kV-35kV insulated lever whole insulated non-partial discharge withstand voltage test electrode test device tester
Technical parameters of the test device
1.KDYDQ-JF10/100 test transformer: No local discharge test transformer. Special structure and precision technology are used to control the volume in a small range. Shape process precision is high. Suitable for field and laboratory use. Convenient and applicable.
Specification: 10kVA/100kV/200V
Rated capacity: 10kVA
Input voltage: 0 ~ 200V
Output voltage: 0 ~ 100kV
voltage accuracy: < AC 1.0%
Output current: 100mA
Insulation medium: SF6
Power distortion: < 3% of the rated voltage system offload ≤5PC
Dimensions: Approx. 340*440*900 (mm)
Weight: About 75kg
2, KDYDQ-JF10 regulator console:
Specification Model: 10kVA/220V
1, this console is a special high voltage test voltage regulator operating platform, equipped with zero start, Stop button; Voltage, ammeter indication, time relay control time and alarm.
2, continuous adjustable operating voltage, waveform without distortion and distortion.
3, with zero function, over current, breakdown protection function.
4, the alarm has sound and light prompts
5, the end of the test, buck back to zero, manual buck.
Rated capacity: 10kVA
Input voltage: 220V±10%
Output current: 50A
Output voltage: 0 ~ 200V
Dimensions: about 730*540*660 (mm)
Weight: About 32Kg
 
Coupling capacitor
Specification Model: 100kV/600pF
Voltage level: 100kV
Voltage ratio: 1000:1 Accuracy: Level 1.5
Protection resistance Resistance value: 20 kω
System offload at rated voltage: ≤5PC
Dimensions: Approx. 260*260*730 (mm)
Weight: About 10Kg
 
withstand voltage tester
Ambient temperature -10ºC-40ºC
Continuous running time can be continuous
Device height 2000 mm x 1000 mm x 6000mm
Maximum voltage 100kV
Test quantity 8
Test mode Perpendicular to ground
Upper electrode clamp 8 sets
Bottom electrode clamp 8 sets
Effective pressure distance 5000mm
Leakage current measuring function and measuring range 0-10mA
Lifting mode Remote lifting
Indoor venue requirements The test chamber is higher than 10000mm
Weight (kg) 80KG

withstand voltage tester10kv-35kv Insulated Lever Whole Insulated Non-Partial Discharge Withstand Voltage Test Electrode Test Device Tester10kv-35kv Insulated Lever Whole Insulated Non-Partial Discharge Withstand Voltage Test Electrode Test Device Tester10kv-35kv Insulated Lever Whole Insulated Non-Partial Discharge Withstand Voltage Test Electrode Test Device Tester10kv-35kv Insulated Lever Whole Insulated Non-Partial Discharge Withstand Voltage Test Electrode Test Device Tester10kv-35kv Insulated Lever Whole Insulated Non-Partial Discharge Withstand Voltage Test Electrode Test Device Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now