• Nanolinks900 Zeta Potential Analyzer Liquid Nano Particle Size Testing Machine
  • Nanolinks900 Zeta Potential Analyzer Liquid Nano Particle Size Testing Machine
  • Nanolinks900 Zeta Potential Analyzer Liquid Nano Particle Size Testing Machine
  • Nanolinks900 Zeta Potential Analyzer Liquid Nano Particle Size Testing Machine
  • Nanolinks900 Zeta Potential Analyzer Liquid Nano Particle Size Testing Machine
  • Nanolinks900 Zeta Potential Analyzer Liquid Nano Particle Size Testing Machine

Nanolinks900 Zeta Potential Analyzer Liquid Nano Particle Size Testing Machine

After-sales Service: Online
Warranty: 1 Year
Type: Zeta Potential Analyzer
Maxcapacity: <1000KN
Accuracy Grade: 1
Load Way: Electronic Load
Samples:
US$ 3000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
NanolinkS900
Display
Digital
Control
Manual Control
Weight
35
Power Source
AC220V
Principle of Measurement
Dynamic Light Scattering
Minimum Sample Concentration
0.1mg/Ml*
Power Requirement
AC 220V, 50Hz-60Hz, Standard Ground
Operating Ambient Humidity
10%-85% Relative Humidity (No Condensation)
Transport Package
Plywood Cases
Specification
68*50*35CM
Trademark
LONROY
Origin
Guangdong
HS Code
9024800000
Production Capacity
200

Product Description

NanolinkS900 Zeta Potential Analyzer Liquid Nano Particle Size Testing Machine 

Characteristics:

Zeta potential analyzers are typically produced due to ion dissociation on the particle surface, leaving a net charge surrounded by a cloud of counter-ions near the surface. Various types of ions can diffuse in and out through sliding surfaces that allow the Zeta potential to vary depending on the ionic composition in the liquid, such as pH. Ions can also influence the Zeta potential by participating in chemical reactions within the sliding surface.

 

The electrostatic potential 1 of particles suspended in a liquid is very close to the surface position. The Zeta potential (ζ) is caused by particle-to-particle interactions in a colloidal system, so it can be used to predict the stability of particle aggregation in a colloidal system. Figure 1 shows particles suspended in a liquid and the various conceptual regions around them. Zeta potential refers to the potential of a sliding or shearing surface in a liquid. In this plane of slip, as the liquid moves freely outside this boundary, it binds to the particle. The net electric potential away from the particle (in the liquid) is zero.

 

In aqueous media, Zeta potential analyzers are usually produced due to ion dissociation on the particle surface, leaving a net charge surrounded by a cloud of counter-ions near the surface. Various types of ions can diffuse in and out through sliding surfaces that allow the Zeta potential to vary depending on the ionic composition in the liquid, such as pH. Ions can also influence the Zeta potential by participating in chemical reactions within the sliding surface. Sample dilution can significantly change the Zeta potential because ions can adsorb or resolve the particles. Thus, the Zeta potential can be positive or negative, or zero (isoelectric point, IEP), depending on the pH of the liquid (solvent) or the type and concentration of ions.
NanolinkS900 is a new generation of nanoparticle particle size analysis system developed based on many years of scientific research results, which is widely used in the particle characterization of organic and inorganic particles, emulsions, polymers, surfactants, colloids, viral antibodies, protein-like samples. In addition to particle characterization, it can also measure the Zeta potential of colloid.

 

NanolinkS900 Zeta Potential Analyzer Liquid Nano Particle Size Testing Machine 

Parameter

principle of measurement dynamic light scattering
particle size range 0.3nm-15μm*
degree of accuracy Better than ±1% (average particle size, NIST-traceable latex standard)
repeatability Better than ±1% (average particle size, NIST-traceable latex standard)
Minimum sample concentration 0.1mg/ml*
Minimum sample size 3μl*
measuring angle Classic 90 degrees
Temperature control range 0ºC-90ºC (120ºCmatch)
Temperature control accuracy ±0.1ºC
condensation control Dry gas purge
laser 532nm solid-state laser, maximum power 50mW, laser output automatically adjustable
Laser safety class Class 1
correlator The minimum sampling time is 25ns and the dynamic range is >1011
detector High sensitivity APD or PMT
computer configuration Intel i5 processor, 4GB RAM, 250GB hard disk and display, mouse and keyboard
computer interface USB 2.0 or above
operating system Windows 7 Or above professional version
operating ambient temperature 5ºC-40ºC
Operating ambient humidity 10%-85% relative humidity (no condensation)
power requirement Ac 220V, 50/60Hz, standard ground
weight 25kg
size 578mm x 397mm x 248mm(LxWxH)
Note: * Depends on sample and pool options

Nanolinks900 Zeta Potential Analyzer Liquid Nano Particle Size Testing MachineNanolinks900 Zeta Potential Analyzer Liquid Nano Particle Size Testing Machine