0.1Hz Program Controlled High Voltage Generator/Ultra Low Frequency Cable Insulation Withstand Voltage Tester
Product Introduction
This product combines modern digital frequency conversion technology, the use of microcomputer control, boost, buck, measurement, protection automation. Because of electronization, so small volume and light weight, large screen LCD display, clear and intuitive, and can display output waveform, print test report. The design indicators conform to the "general technical conditions for special test instruments for power equipment, Part 4: General technical conditions for ultra-low frequency high voltage generators" power industry standards, easy to use. Now both at home and abroad use mechanical methods for modulation and demodulation to generate ultra-low frequency signals, so there is a sine wave waveform is not standard, the measurement error is large, the high voltage part has spark discharge, the equipment is bulky, and the two, four quadrants of the sine wave also need high power high voltage resistor discharge shaping, so the overall power consumption of the equipment is large. This product has no such shortcomings, in addition, there are the following characteristics need special explanation:
1. Current, voltage and waveform data are directly sampled from the high voltage side, so the data are accurate.
2. With over-voltage protection function, when the output exceeds the set voltage limit value, the instrument will stop protection, the operation time is less than 20ms.
3. With over-current protection function: designed for high and low voltage dual protection, high voltage side can be precise shutdown protection according to the set value; When the current of the low voltage side exceeds the rated current, the shutdown protection will be carried out, and the operation time is less than 20ms.
4. The high voltage output protection resistor is designed in the boost body, so there is no need for another protection resistance outside.
5. Because of the use of high and low voltage closed-loop negative feedback control circuit, the output has no capacity rise effect.
0.1Hz Program Controlled High Voltage Generator/Ultra Low Frequency Cable Insulation Withstand Voltage Tester
1. Output rated voltage:
Rated voltage |
Carrying capacity |
Power supply
Safety insurance tube |
Product structure, weight |
30kV
(Peak value) |
0.1Hz,≤1.1µF |
10A |
Controller: 4KG
Booster: 25KG |
0.05Hz,≤2.2µF |
0.02Hz,≤5.5µF |
50kV
(Peak value) |
0.1Hz,≤1.1µF |
10A |
Controller: 4KG
Booster: 35KG |
0.05Hz,≤2.2µF |
0.02Hz,≤5.5µF |
80kV
(Peak value) |
0.1Hz,≤1.1µF |
15A |
Controller: 4KG
Booster: 50KG |
2. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz
3. Load capacity: 0.1Hz, maximum 1.1µF; 0.05Hz, maximum 2.2µF; 0.02Hz with a maximum of 5.5µF 4. Measurement accuracy: 3%
5. Voltage positive, negative peak error: ≤ 3%
6. Voltage waveform distortion: ≤ 5%
7. Conditions of use: indoor, outdoor; Temperature: -10ºC ~ +40ºC; Humidity: ≤ 85%RH
0.1Hz Program Controlled High Voltage Generator/Ultra Low Frequency Cable Insulation Withstand Voltage Tester
9. Municipal power supply: frequency 50Hz, voltage 220V±5%. If the use of portable generator power supply, generator requirements: frequency 50Hz, voltage 220V±5%, power should be greater than 3KW, and in the output of the generator in parallel a power of not less than 800W resistive load (such as electric furnace), in order to stabilize the speed of the generator. Otherwise the instrument will not work properly.
Products with appropriate specifications were selected according to the subject's orientation. When used, the capacity of the test shall not exceed the rated capacity of the instrument. If the sample capacitance is too small, it will affect the output waveform. If it is less than 0.05µF, the instrument will not output normally. In this case, the capacitor of 0.05µF (provided by the company) can be connected in parallel to assist the output. The following is the electrical capacity of some devices for user reference.
0.1Hz Program Controlled High Voltage Generator/Ultra Low Frequency Cable Insulation Withstand Voltage Tester
Single-phase to ground electric capacity of different generators
|
Pyroelectric power |
Water and electricity |
Generator capacity
(MW) |
200 |
300 |
600 |
85 |
125-150 |
300 |
400 |
Single-phase capacitance to ground (µF) |
0.2-0.25 |
0.18-0.26 |
0.31-0.34 |
0.69 |
1.8-1.9 |
1.7-2.5 |
2.0-2.5 |
Capacitance of Cross-linked Polyethylene Insulated Single-core Power Cable (µF/km)
Cross section Capacitor mm2 µF/Km
Voltage kV
|
16 |
25 |
35 |
50 |
70 |
95 |
120 |
150 |
185 |
240 |
270 |
10 |
0.15 |
0.17 |
0.18 |
0.19 |
0.21 |
0.24 |
0.26 |
0.28 |
0.32 |
0.38 |
- |
35 |
- |
- |
- |
0.11 |
0.12 |
0.13 |
0.14 |
0.15 |
0.16 |
0.17 |
0.19 |
