  • DRL-III Heat flow method Thermal conductivity testerThermal resistance tester ASTM D5470
  • DRL-III Heat flow method Thermal conductivity testerThermal resistance tester ASTM D5470
  • DRL-III Heat flow method Thermal conductivity testerThermal resistance tester ASTM D5470
  • DRL-III Heat flow method Thermal conductivity testerThermal resistance tester ASTM D5470
  • DRL-III Heat flow method Thermal conductivity testerThermal resistance tester ASTM D5470
  • DRL-III Heat flow method Thermal conductivity testerThermal resistance tester ASTM D5470
Find Similar Products
  • Overview
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
DRL-III
Type
thermal conductivity tester
Power Source
AC220V
Test accuracy
better than 3%.
Transport Package
Plywood Case
Specification
300× 350× 530mm
Trademark
langshuo
Origin
China
HS Code
9024800000
Production Capacity
200

Product Description

DRL-III Heat flow method Thermal conductivity testerThermal resistance tester ASTM D5470
1.Product introduction

It is mainly used to test the thermal resistance of thin thermal conductors, solid electrical insulating materials, thermal conductive silicone grease, resin, rubber, beryllium oxide porcelain, alumina porcelain and other materials, as well as the contact thermal resistance at the solid interface and the thermal conductivity of the material. The detection material is solid sheet, and the enclosed frame can detect powder state material and paste material. Instrument reference standard: MIL-I-49456A "Insulation sheet, heat conductive resin, heat conductive glass fiber reinforcement"; GB/T 5598-2015 "Beryllium oxide porcelain thermal conductivity determination method"; GB/T 29313-2017 "Test method for heat conduction properties of electrical insulating materials"; ASTM D5470-2017 "Test standard for Heat transfer Performance of Thin Thermally Conductive Solid Electrical Insulating Materials", etc.

DRL-III thermal conductivity meter is designed and manufactured in accordance with ASTM D5470-2017 standard. Our company has accumulated more than ten years of experience in manufacturing and user practice, so that the product performance continues to improve and mature. Servo motor control precision automatic pressure, automatic thickness measurement device, and connected to the computer to achieve automatic control. The instrument adopts 6-point temperature gradient detection to improve the test accuracy. A thermal protection device (thermal protection of the sample) is added around the test rod in the test head to reduce the influence of ambient temperature on the test. Thermal resistance curves under different pressures can be detected, and multiple parameters such as thermal conductivity, thermal resistance and contact thermal resistance at the interface can be measured by using optimized mathematical models. Using the latest technology cold end temperature automatic compensation, no longer need to add ice water compensation device.

Users can choose standard and small models (with the same performance) according to the actual occupation area, saving laboratory space.

Widely used in colleges and universities, scientific research units, quality inspection departments and production plants of material thermal analysis and detection.
Product Parameters
DRL-III Heat flow method Thermal conductivity testerThermal resistance tester ASTM D5470
2. Product Parameter
sample size
 
Φ30mm or 20x20mm (standard configuration), other sizes can be customized
thermal conductivity
 test range
 
0.001 ~ 50W/m.k, 0.001 ~ 300W/m.k, computer software automatic switching range;
 
thermal resistance
test range
 
0.05 ~ 0.000005 M2.K/W
 
sample thickness
 
0.001 ~ 50mm (standard configuration)
, typical thickness: 0.02 ~ 20mm
thermal pole
temperature control range
 
room temperature ~ 100ºC (standard configuration), room temperature ~ 299.99ºC, room temperature ~ 500ºC, temperature control accuracy 0.01ºC
 
cold pole
temperature control range
 
0 ~ 99.00ºC, temperature control accuracy 0.01ºC (equipped with high precision, large capacity low temperature sink)
 
pressure range
 
0 ~ 1000N, servo motor control, can accurately set the pressure value, control accuracy 0.1N
 

thickness range
 
0 ~ 50.00mm, accuracy 0.1um, automatic thickness measurement
 
number of samples
 
1 piece (multiple films)
test accuracy
 
better than 3%
Test methods thermal resistance test under different pressures of samples, thermal conductivity test of materials, contact thermal resistance test, aging reliability test, compression performance test of materials, contact thermal resistance test between samples
power supply 220V/50Hz; 500W
computer automatic test, and realize data printing output

DRL-III Thermal conductivity tester (heat flow method) Thermal resistance tester ASTM D5470
3. Typical test materials


1, metal materials, stainless steel; 2, heat conduction silicone grease;

3, thermal conductivity silicone pad; 4. Thermal engineering plastics;

5, thermal tape (the sample is very thin and sticky, it is difficult to make a regular single sample, one side is fixed with transparent plastic and the other side is fixed with paper);

6, aluminum substrate, copper clad plate; 7, quartz glass, composite ceramics;

8, copper foam, graphite paper, graphite sheet and other new materials.

DRL-III Thermal conductivity tester (heat flow method) Thermal resistance tester ASTM D5470
4.complete set


1. One host computer;

2. A set of analysis software (Chinese and English versions);

3, HX-1005 precision low temperature constant temperature tank one (temperature control accuracy 0.01ºC);

4, a Lenovo computer (users can choose);

5. Two standard samples;

6, a set of random accessories (fat, paste, powder test box, sample convenient sheet forming stamping die each set).

DRL-III Thermal conductivity tester (heat flow method) Thermal resistance tester ASTM D5470
5. Dimensions and weight


1, host: standard landing model: (length × width × height) 550×450×1550mm, net weight: 100Kg,

Small desktop model: (length × width × height) 500×400×780mm, net weight: 60Kg;

2, precision low temperature constant temperature tank: (length × width × height) 300×350×530mm, net weight: 35Kg.

DRL-III Thermal conductivity tester (heat flow method) Thermal resistance tester ASTM D5470
6. Technical services


1, one year free warranty, long-term technical services, software lifetime free upgrade.

2. Free on-site installation and debugging throughout the country. All over the country has the company's mobile technical personnel, can provide technical services.

 