KGYD AC/DC Power Frequency Withstand Voltage Test Device High Voltage Hipot Tester ISO9001
Product Introduction
KGYD power frequency withstand voltage test equipment is widely used in electrical manufacturing departments, power operation departments, scientific research institutions and universities. The power frequency voltage withstand test device is divided into two categories: integrated device (below 30kV) and split device. The voltage test device is the most strict, the most effective and the most direct method to identify the insulation strength of power equipment. It can check the concentrated defects that are more dangerous, play a decisive role in judging whether the power equipment can continue to participate in the operation, and is an important means to ensure the insulation level of the equipment and avoid insulation accidents.
KGYD AC/DC Power Frequency Withstand Voltage Test Device High Voltage Hipot Tester ISO9001
Product Parameters
1. Control box parameters:
1, Input voltage: 220V±10% 50Hz
2, output voltage: 0 ~ 250 (430) V
3, output capacity: 0 ~ 5kVA
4, timing range: 1S ~ 99H
5, ambient temperature: -20ºC to 50ºC
KGYD AC/DC Power Frequency Withstand Voltage Test Device High Voltage Hipot Tester ISO9001
Product Characteristics
1, monitoring function: output current meter voltage zero indicator power indicator work indicator timing indicator;
2, protection function: overcurrent protection time relay;
3, the use of new time relay, timing range is wider;
4, the use of new current relay, more accurate, more reliable, to ensure personal and equipment safety;
5, reasonable structure, small size, light weight.
KGYD AC/DC Power Frequency Withstand Voltage Test Device High Voltage Hipot Tester ISO9001
Test transformer parameter
specification |
specification KVA |
low pressure side | high-pressure side | Measurement ratio | 60Wind temperature riseºC | impedance voltage% | no-load current% | quality Kg | Overall dimension Length × width × height mm×mm×mm |
||
voltage V |
electricity A |
voltage KV |
electricity mA |
||||||||
1.5/50 | 1.5 | 200 | 7.5 | 50 | 30 | 500 | 50 | 10 | <4 | 19.5 | 200×275×640 |
3/50 | 3 | 200 | 15 | 50 | 60 | 500 | 50 | 10 | <4 | 27 | 240×300×690 |
5/50 | 5 | 200 | 25 | 50 | 100 | 500 | 50 | 10 | <4 | 52 | 250×355×710 |