Product Features The main control functions of the control system are as follows: Measurement display quantity: Dc charging voltage Transformer primary side current The sphere gap distance of the generator body State display size: The on-off state of the main power contactor Switching state of the grounding device The triggering state of the generator ball gap Generator charging voltage polarity state Control: The control function has manual, automatic and program control functions, and the functions of each level are relatively independent. Using SCR voltage regulation mode, with charging voltage feedback measurement system. Ignition ball gap and intercept ball gap distance can be adjusted manually and automatically, and displayed on the LCD panel. It has a cut wave trigger pulse with adjustable time delay and a feedback system triggered by generator ignition. The stability of the charging voltage can reach 0.5% by using the constant current charging mode controlled by function. The LCD panel can indicate the charging voltage and charging process of the impact generator with an accuracy of 1%. The charging voltage and charging time can be directly input by the LCD panel. It has the function of abnormal charging protection, which can automatically or manually send out the trigger ignition pulse The indication of the working state of the impact generator, such as spontaneous combustion, no trigger, abnormal charging, stable charging, etc. Ground and ground release control of the main body of the equipment and the charging part. The charging voltage polarity can be automatically converted by the button on the controller The charging process of the charging voltage can be controlled automatically or manually Alarm can be sounded automatically or manually Protection and interlocking: Over current protection Over voltage protection Charging anomaly protection Door switch interlock Grounding mechanism interlocking Polarity conversion linkage Operation Tips: With a variety of operation prompt screen, when the system error or improper operation when the corresponding prompt screen.
Lightning Impact High Voltage Generator/Temperature Rise Test Machine/Lightning Impulse Voltage Generator
Charging voltage setting range
0 ~ 100kV
The working range
20 ~ 100kV
The setting deviation
≤ ±1%
Tuning resolution
0.1kV
The charging time tuning range
30~180s
The tuning resolution
1s
alarm delay
2s
The setting range of pressure times
1~999
trigger pulse
greater than 15kV, the rise time is less than 100ns, and the polarity can be switched
Overcurrent protection value can be set
Overvoltage protection value can be set
Dynamic charging protection can be set