• ISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size Measurement
  • ISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size Measurement
  • ISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size Measurement
  • ISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size Measurement
  • ISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size Measurement
  • ISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size Measurement

ISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size Measurement

After-sales Service: Online
Warranty: 1 Year
Type: Laser Particle Size Analyzer
Maxcapacity: <1000KN
Accuracy Grade: 1
Load Way: Electronic Load
Samples:
US$ 3000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
LR-N009
Display
Digital
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Test Range
1-10000nm(Related to Samples)
Concentration Range
0.1mg/L-100mg/L (Sample Related)
The Sample Pool
10mm*10mm , 4ml
The Rated Voltage
AC110V/ AC220V
Transport Package
Plywood Cases
Trademark
LONROY
Origin
Guangdong
HS Code
9024800000
Production Capacity
200

Product Description

ISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size Measurement 

LR-N009 optical related nano particle size meter

LR-N009 is the latest nano particle analyzer based on the principle of dynamic light scattering. It adopts high speed photon correlator and professional high performance photomultiplier tube as the core device, which has the characteristics of fast, high resolution, repetition and accuracy, and is the preferred product for the determination of particle size of nanoparticles.

ISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size Measurement 

Main performance features:

Advanced testing principle: the instrument adopts the principle of dynamic light scattering and photon correlation spectroscopy technology, according to the particle in the liquid Brownian motion speed determination of particle size, small particles Brownian motion speed fast, large particles Brownian motion speed slow. When the laser beam irradiates on the moving particles, the scattered light at a certain Angle (90 degrees is used in this instrument) changes dynamically with time, and the speed of change is related to the Brownian motion speed of particles in the liquid. The photon correlation spectroscopy method is used to carry out statistical analysis and correlation operation on the dynamic scattering spectrum. The particle size was calculated according to Stokes-Einstein equation.

 

ISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size Measurement 

High sensitivity and SIGNal-to-noise ratio: HAMAMATSU professional high-performance photomultiplier tube (PMT) with low dark count and high sensitivity is used as the detector, which has extremely high sensitivity and signal-to-noise ratio for photon signals, thus ensuring high accuracy and high resolution of test results;

Powerful computing capabilities: To use PCS technology to determine the size of nanoscale particles, it is necessary to be able to distinguish nanosecond signal fluctuations. The core part of the instrument adopts high-speed photon correlator developed by ASIC, which has high resolution of 6ns and high signal processing speed. It can collect photon number and calculate correlation operation in real time quickly, laying the foundation for test accuracy.

Stable optical path system: using thermostatic control of high-power semiconductor laser and optical fiber combination built by the photon correlation spectrum detection system, so that it is not only small in size, but also has strong anti-interference ability and stability, to ensure the repeated stability of test results;

High precision temperature control system: sample pool temperature control system and laser temperature control system accuracy up to ±0.1ºC, so that the tested sample and laser light source in the whole test process are in a constant temperature state, to avoid the impact of temperature change on the test results, to ensure the accuracy and repeatability of the test;

Super functional analysis software: the inversion algorithm in the analysis software adopts the accumulative measurement method recommended by international standards as well as the non-negative least square method (NNLS) and Contin and other algorithms, and the test results are in good consistency with the international authoritative similar products.

Accurate and stable test: The perfect combination of high-performance hardware and standardized international inversion algorithm makes the LR-N009 precise and repeatable test results, and its test accuracy and repeatability are higher than the requirements of international standards.

New heat dissipation system: the new LR-N009 carries out a dual airflow design, hot gas directly discharged from the instrument housing, multiplier tube, laser, correlator and other important components are no longer affected by the hot airflow, the measurement data is more accurate, more stable, while greatly extending the service life of these important components.

Automatic sensing sliding door: the new LR-N009 is equipped with the automatic opening and closing function of the colorimetric door. When the hand is close to the instrument, the sliding door will automatically open to facilitate the tester to take the colorimetric door, and when the hand is far away from the instrument, the sliding door will automatically close.

This nano particle meter has reached the testing level of foreign nano particle meter!

 

ISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size Measurement 

Technical parameters and detailed configuration

specifications

 LR-N009

Execution standard

GB/T 29022-2012/ISO 22412:2008

Test range

1-10000nm(related to samples)

Concentration range

0.1mg/L-100mg/L (sample related)

Accuracy error

< 1% (average particle size of national standard sample)

Repeatability error

< 1% (average particle size of national standard sample)

laser

Main laser: λ=532nm, semiconductor laser /LD pumped laser, P > 30mW

The detector

Photomultiplier tube (PMT)

Scattering Angle

90 °

The sample pool

10mm*10mm , 4ml

Temperature range

5-90ºC (accuracy ±0.1ºC)

The rated voltage

AC110V/ AC220V

Try speed

< 1Min/ time (excluding sample dispersion time)

Photon correlator

Physical channel: 512, equivalent channel: 10000, baseline channel: 8

Sampling and delay time: 1us~200us dynamic adjustable

Minimum resolution: 6ns

 

ISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size MeasurementISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size MeasurementISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size MeasurementISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size MeasurementISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size MeasurementISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size MeasurementISO22412 Full Automatic Spray Laser Particle Size Analyzer Particle Size Measurement