H1600 Portable dual channel isothermal amplification fluorescence detector
Product Introduction:
H1600 isothermal amplification fluorescence detection system is a portable isothermal amplification fluorescence detection instrument developed by Boheng Company. This product adopts dual-channel dual-8-hole module design, which can realize multi-purpose, as well as embedded 7-inch high-definition TFT color touch screen, WIN10 operating system, with its own analysis software, can complete quantitative analysis and print report without computer. It uses MARLOW customized Parstick module, high sensitivity photodetector and side scanning technology to ensure superior performance and stable detection results.
H1600 Portable dual channel isothermal amplification fluorescence detector
Application
This product can be used for real-time detection of pasture, forest farm, breeding farm and water source, rapid diagnosis of disaster, epidemic prevention and control, animal disease, food safety inspection and quarantine, as well as scientific research in biological laboratory.
H1600 Portable dual channel isothermal amplification fluorescence detector
Features of the instrument
1) Dual-channel dual-module design, free collocations experiment, can realize the independent operation of 2 different programs;
2) Small size, light weight, easy to carry;
3). With software analysis function, qualitative/quantitative analysis can be carried out;
4). 7-inch capacitive touch screen, Win10 operating system, simple operation, easy to start experiments;
5). Built-in 20G Flash memory, which can save up to 40,000 experimental data;
6) Optional printer, no need to connect to the computer directly print experimental results;
7) Using side scanning technology, the detection distance is close, the fluorescence acquisition signal is stable;
8). Dark-box reaction tank to avoid background noise;
9) Adopt the same acquisition optical path to improve repeatability;
10). LED light source, energy saving and environmental protection, long service life, maintenance-free;
11). Unique suction type electromagnetic lock cover technology;
12). The front soft shutdown button can prevent the accidental file or data loss caused by hard shutdown;
13). Constant current control circuit, smooth power output, prolong Peltier life, improve temperature control accuracy;
14). With over current, over temperature, power down data self-recovery and other protection functions, to ensure the safe operation of the experiment;
15). Forward and back out air duct design, can be placed side by side, saving laboratory space;
16). Can support lithium battery power supply, especially suitable for quick inspection and field inspection.
H1600 Portable dual channel isothermal amplification fluorescence detector
Technical parameters
Model number of products |
H1601 |
H1602 |
Volume of sample |
16×0.2ml (2×8 well, double module) |
Applicable consumables |
0.2ml thin wall transparent single tube,0.2ml thin wall transparent eight tube |
System of reaction |
15-100μl |
Temperature control technology |
American MARLOW semiconductor refrigerator, more than 1 million cycles |
Temperature control range |
0-100 ° C (resolution: 0.1 ° C) |
Maximum rate of rise and fall |
6ºC/s |
Temperature control accuracy |
±0.1 ºC |
Homogeneity of temperature |
±0.25 ºC |
Accuracy of temperature |
±0.25 ºC |
Hot cover temperature range |
30-115 ° C (adjustable, default 105 ° C) |
Temperature control mode |
Block mode, Tube mode (automatic control according to the reaction volume) |
Fluorescence excitation light wavelength |
460-550nm |
Fluorescence detection wavelength |
F1:520-540nm |
F1:520-540nm F2:540-580nm |
Suitable for fluorescent dyes |
F1:FAM/SYBR Green |
F1:FAM/SYBR Green I
F2: HEX/VIC/JOE/TET |
Excitation light source |
High brightness LED, long service life, no maintenance |
Detector/detector |
High sensitivity photoelectric sensor |
Range of dynamics |
1-1010 Copies |
Sensitivity of detection |
Single-copy genes can be detected |
Software analysis function |
Qualitative/quantitative analysis |
Data export format |
excel,csv,txt |
Print out |
You can print reports directly (USB thermal printer is optional) |
Method of control |
7 inch color touch screen control, can also be connected to the computer control |
Mode of interface |
WIFI/usb |
Volume of volume |
300x267x198mm(L x W x H) |
Weight |
8 KG |
Operating voltage |
220VAC, 50Hz |
Power |
DC15V 255W |
![H1600 Portable Dual Channel Isothermal Amplification Fluorescence Detector](//www.micstatic.com/athena/img/transparent.png)
![H1600 Portable Dual Channel Isothermal Amplification Fluorescence Detector](//www.micstatic.com/athena/img/transparent.png)