High and low voltage cable street light line buried underground cable short-circuit leakage fault comprehensive test detector
Functional characteristics
Can receive high sensitivity, low static drift, high positioning accuracy, strong anti-interference ability LCD display signal and state built-in high-performance electric rechargeable battery. The instrument adopts high-speed data sampling technology, A/D sampling speed is 100MHZ, so that the instrument read resolution is 1M, 3 detection blind area is 1M
The test is failsafe, fast and accurate. The instrument adopts low voltage pulse method and high voltage flashover method to detect and test various faults of cable, especially for low voltage cable path finder, cable grounding fault finder, neutral line grounding fault finder, buried cable path and grounding fault finder, line path finder.
With a high thermal printer, the data measured on the spot can be printed in real time.
Sound function: The tone change emitted by the receiver through the horn intuitively reflects the measured signal size. Left and right indicators: Left and right indicators show the fault location.
Tracking tips: at some frequencies, real-time measurement of the pipeline current direction, to achieve tracking correct and wrong, eliminate the interference of the line.
Ground fault finding: Use the A-frame (optional) to locate the ground insulation damage of the pipeline without zeroing, and the left and right indicators show the direction of the fault point.
Full digital high-precision sampling and processing, receiving pass band is extremely narrow, anti-interference ability can fully suppress the power frequency and harmonic interference of adjacent running cables and pipelines.
High and low voltage cable street light line buried underground cable short-circuit leakage fault comprehensive test detector
Cable fault comprehensive tester |
Power consumption :5VA |
Test cable voltage level:100V~35KV |
Positioning accuracy :<±10cm |
Maximum test distance :0-35KM(open line up to 100km) |
Buried depth detection: < 3M |
Data storage :100 pieces |
Fault point error :0.5M charging |
Power supply :AC220V 10% |
Total length error :0.3M |
Charging time :4-8 hours |
Transmission speed :10~200M/S |
Battery life :5 hours |
Reading resolution :0.5M |
Battery voltage and capacity :DC12V(7AH) |
Positioning impedance range :0~5MQ |
Path signal transmitter |
Battery voltage and capacity :DC12V(7AH) |
Output voltage: up to 100VPP |
Maximum output power :10W |
Output frequency: automatic matching |
Power consumption :1.0W |
Receiver sensitivity :6E-15TESLA,5UA |
Troubleshooting: Detect cables up to 2M with A frame |
Acoustic magnetic fixed point accuracy :+0.5M ground fault |
Positioning accuracy: ±05M |
Charging power supply :AC220V10% |
Test path error: ±0.5M |
Charging time :4-8 hours |
Maximum test line buried depth :4.5 meters |
Battery life :8 hours |
Maximum pulse peak output current :10A |