• CT Volt-Ampere Characteristic Variable Ratio Polarization Tester/Current Transformer Va Characteristic Comprehensive Tester
  • CT Volt-Ampere Characteristic Variable Ratio Polarization Tester/Current Transformer Va Characteristic Comprehensive Tester
  • CT Volt-Ampere Characteristic Variable Ratio Polarization Tester/Current Transformer Va Characteristic Comprehensive Tester
  • CT Volt-Ampere Characteristic Variable Ratio Polarization Tester/Current Transformer Va Characteristic Comprehensive Tester
  • CT Volt-Ampere Characteristic Variable Ratio Polarization Tester/Current Transformer Va Characteristic Comprehensive Tester
  • CT Volt-Ampere Characteristic Variable Ratio Polarization Tester/Current Transformer Va Characteristic Comprehensive Tester

CT Volt-Ampere Characteristic Variable Ratio Polarization Tester/Current Transformer Va Characteristic Comprehensive Tester

After-sales Service: Online
Warranty: 1 Year
Type: Va Characteristic Tester
Control: Computer Control
Weight: 0-100Kg
Power Source: AC220V
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
KDHG-A
Transport Package
Plywood Case
Trademark
LONROY
Origin
China
HS Code
9024800000
Production Capacity
200pieces/Month

Product Description

CT volt-ampere characteristic variable ratio polarization tester/Current transformer VA characteristic comprehensive tester

Product overview
Transformer comprehensive tester is a kind of multifunctional field test instrument specially designed for testing transformer: volt-ampere characteristics, ratio, polarity, error curve, calculating inflection point, AC voltage withstand and secondary side loop inspection.

During the experiment, only need to set the test voltage and current value, and the equipment can automatically boost the voltage/current, and the transformer's volt-ampere characteristic curve or ratio, polarity and other experimental results are quickly displayed, supporting data saving and on-site printing, not only eliminating manual voltage regulation, manual recording, curve tracing and other complicated labor. The test data can also be uploaded to the computer through the USB interface for editing and saving or printing.

Simple and convenient operation, improve work efficiency, is a cost-effective high-tech products.

CT volt-ampere characteristic variable ratio polarization tester/Current transformer VA characteristic comprehensive tester
Main feature
1, MBC power control technology, single-phase AC220V input power supply, and the working power supply and power supply share an input port, the design is more scientific and reasonable, the use of more safe and reliable.
2, the equipment power output is the real voltage and current value, and the waveform is the standard sine wave, the frequency is 50-60Hz; It can effectively simulate the real state of the transformer and meet the relevant national maintenance regulations.
3, single 220V input maximum voltage output 0-1000V, single maximum current output 0-600A.
4, can detect CT/PT voltammetry characteristics, ratio, polarity, 5% and 10% error curves, CT primary flow and CT demagnetization and other items, easy to achieve a multi-purpose machine.
5, using a single power input port; Only 8 test ports can complete the CT/PT test, the connection mode is safe and simple, very suitable for field use, can effectively reduce labor intensity and improve work efficiency;
6, for CT ratio measurement range 25000A / 5A, 5000A / 1A. PT ratio test range 500KV: 100V
7. Thermal printer is used to automatically screen and print typical report usage data, which is very suitable for on-site data comparison.
8, can save 1000 sets of test data, not lost after power failure.
9, easy to connect to the new laptop.
10, small size, light weight: easy to use on site.

CT volt-ampere characteristic variable ratio polarization tester/Current transformer VA characteristic comprehensive tester

Main test function
For current transformer (CT) :
1, volt-ampere characteristic test
2. Variable ratio test
3. Polarity discrimination
4. 5% and 10% error curves
5. Secondary loop
6, automatic demagnetization
7, AC withstand voltage

For voltage transformers (PT) :
1, volt-ampere characteristic test
2. Variable ratio test
3. Polarity discrimination
4, automatic demagnetization
5, AC withstand voltage

working power supply AC220V±10V
voltage output 0~1000V(20A peak)
current output 0~600A
detection accuracy ≤0.5%
detection range 25000A/5A; 5000A/1A
operating temperature -10ºC ~ +50ºC
 storage and transportation -25ºC ~ +70ºC
 relative humidity  5~90% (no condensation)
volume (WxHxD) 400x300x260(mm)
weight  ≤18 Kg (without accessories)


CT Volt-Ampere Characteristic Variable Ratio Polarization Tester/Current Transformer Va Characteristic Comprehensive TesterCT Volt-Ampere Characteristic Variable Ratio Polarization Tester/Current Transformer Va Characteristic Comprehensive TesterCT Volt-Ampere Characteristic Variable Ratio Polarization Tester/Current Transformer Va Characteristic Comprehensive TesterCT Volt-Ampere Characteristic Variable Ratio Polarization Tester/Current Transformer Va Characteristic Comprehensive TesterCT Volt-Ampere Characteristic Variable Ratio Polarization Tester/Current Transformer Va Characteristic Comprehensive Tester