Wet and Dry Combined Salt Spray Tester Salt Spray Corrosion Test Chamber Salt Fog Chamber

Product Details
Customization: Available
After-sales Service: Online After-Sales Service
Power Supply: 380V
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
6
Year of Establishment
2020-01-13
  • Wet and Dry Combined Salt Spray Tester Salt Spray Corrosion Test Chamber Salt Fog Chamber
  • Wet and Dry Combined Salt Spray Tester Salt Spray Corrosion Test Chamber Salt Fog Chamber
  • Wet and Dry Combined Salt Spray Tester Salt Spray Corrosion Test Chamber Salt Fog Chamber
  • Wet and Dry Combined Salt Spray Tester Salt Spray Corrosion Test Chamber Salt Fog Chamber
  • Wet and Dry Combined Salt Spray Tester Salt Spray Corrosion Test Chamber Salt Fog Chamber
  • Wet and Dry Combined Salt Spray Tester Salt Spray Corrosion Test Chamber Salt Fog Chamber
Find Similar Products

Basic Info.

Model NO.
LR-B008
Warranty
1 Year
Name
Wet and Dry Combined Salt Spray Tester
Mdoel
Lr-B008
Brine Spray Laboratory
Nss, Cass
Saturated Air Bucket
47ºC ±1ºC
Transport Package
Plywood Box
Trademark
lonroy
Origin
China
HS Code
9024800000
Production Capacity
200PCS/Month

Product Description

 

Wet And Dry Combined Salt Spray Tester salt spray Corrosion test chamber Salt Fog Chamber
Meet the standards:

GB/T5170.8, GB/T10587, GJB150.11, GB/T10125, GB/T2423.17, etc.
DIN50021 DIN50017 DIN50907 ISO 11977 ISO 9227 ASTM B117
ASTM G85 automobile and other industrial specifications.

1.Experimental space: 900×600×500(W×D×H)mm other sizes can be customized
2.Outer space: according to the actual size
3. Power supply: 380V 6KW 50HZ MAX 30A
4. Materials:
(A) imported PVC board is adopted in the laboratory, which is acid and alkali resistant.
(B) imported PVC board in the outer box, resistant to acid and alkali.
(C) the test replenishment tank is equipped with a hidden water table, which is easy to clean and not easy to break.
(D) the saturated air barrel adopts SUS#304 stainless steel high-pressure barrel with the best insulation effect.
5, according to customer test requirements, can be set the salt dry and wet composite test
Salt spray test - moisture/Wet test
(A) brine spray laboratory: NSS, CASS
(1) laboratory: 10ºC ~ 50 ºC
(2) saturated air bucket: 47ºC ±1ºC
(B) moisture test:
(1) temperature: 40ºC ±2ºC
(2) humidity: more than 93%~100%
(2) saturated air bucket: 47ºC ±1ºC
(C) drying test:
(1) temperature: 15ºC~50ºC ±1ºC
(2) humidity: over 30%
6. Air supply system
The air pressure is 1kg/cm2, which can be adjusted in two stages. The first is the imported pressure regulating filter with the function of filtering water.
Adjust to 2-2.5kg/ cm2 roughly, the second is the imported precision pressure regulating valve, adjust to the pressure gauge 1kg/ cm2.
7. Spray method:
1. Apply bernouldt principle to take and absorb salt water and atomize it, the atomization degree is even, without blocking crystallization, to ensure the standard of continuous test.
2. Nozzle: made of special glass nozzle, the size and Angle of spray can be adjusted.
3. Spray volume: adjustable 1.5± 0.5ml 80cm2/Hr (16-hour average volume).
4. large brine storage tank, 48HR continuous spray.
8.Heating system:
External hot air heating method is adopted to reduce standby time and component damage rate.
S.S.R control heating power, accurate temperature, low power consumption.(titanium alloy corrosion prevention tube for electric heat pipe)
9. Circuit control system
1. The main controller adopts 7-inch LCD human-machine interface, and the main screen can plan the test program.
2. The fixed time can be set 0-999 H 59 MIN.
3. The program mode can set salt spray and moisture test at the same time
4. With power off memory device, the remaining program can be continued when power back.
5. The rise and drop of temperature can be used for speed control and self-calibration of temperature and humidity reference points.
6. Temperature and humidity sensor the DIN PT - 100 Ω (platinum).
Wet And Dry Combined Salt Spray Tester salt spray Corrosion test chamber Salt Fog Chamber
10.Inlet and drainage system:

The water inlet adopts the automatic water replenishment system. When the water level is too low, it will be replenished automatically, and manual water replenishment can be used.
Drainage water pump with acid, alkali and corrosion resistance, increase the service life, reduce the waiting time for drainage.
All pipeline accessories are imported acid-alkali corrosion resistant components, long life.
11.. Humidification system:
1. Electronic bit mode P.I.D micro humidification system is adopted.
2. Attached overheat and overflow double protection device.
3. The humidification and dehumidification systems are completely independent.
4. Water level control mining height molecular floating ball water valve.
5. Automatic humidifying water replenishment device.(the machine should be connected to the water source)
12. Dehumidification system
The evaporator condenses and dehumidifies, and the humidity is stable.
Bubble acceleration humidifier, humidity stability rate is fast.
Adopt high speed return air extraction system.

Wet And Dry Combined Salt Spray Tester salt spray Corrosion test chamber Salt Fog Chamber
13. Safety protection device:

1. With leakage power off type no fuse protection switch.
2. Low water level protection switch.
3. Low-salt protection switch
4. Double overtemperature protection device can prevent mechanical or electronic movement from losing control.
5. Failure point Chinese indication screen.
14. Contents:
1. 6 shelves
2. Two standard measuring tubes
3. 2 glass filters
4. Collector 80cm2 2
5. 2 glass nozzles
15. Attachment: 500g of test drug sodium chloride (NACL), 2 bottles of operation manual, 1 copy
16. Operating environment: performance guarantee environment temperature range :+5ºC ~ +30ºC (but the lowest available temperature, the highest thermal load energy
Force and cooling time excepted)
  1. Power supply: 380V three-phase 50HZ MAX 30A

Function Introduction
Salt fog environment
Continuous salt spray exposure is widely used to test the corrosion resistance of components and coatings.Applications include industrial, maintenance, construction and Marine coatings;Plating and paint layers;Aviation and coatings, surfaces and components, electrical and electronic systems and components.
Most of these tests, according to special specifications, are widely used in related corrosion tests and generally operate at higher temperatures, excluding the drying cycle.The required jet air should be heated before entering the nozzle.
During the salt spray function, this test chamber ACTS as a typical conventional salt spray operation.
· the air jet solenoid valve opens and the compressed air is humidified through the saturator (humidity helps keep the PH concentration stable) to the nozzle.
· the corrosive solvent from the brine tank is sucked to the nozzle where it is mixed with compressed air.
· the nozzle will spray the brine solvent and air into a corrosive mist.
· the box heater maintains the programmed box temperature.
This function is also used for pure water mist exposure.
Dry environment
During the drying function, the dehumidification system is turned on to discharge the moisture from the box out of the box, while the fan works so that the indoor air goes to the air heater and then into the box, thus creating low humidity conditions in the box.The temperature of the cabinet is controlled by the cabinet heater and the air heater.The air heater is shut down for 5 seconds before the end of the drying process so that the heater channel and the vicinity of the components do not overheat due to the closing of the blower.
Humidity environment
During the humidity function, hot water in the humidification tank boiler is evaporated into the tank to keep the set humidity of the tank.

Condensate environment
During the condensation process, the water in the tank is heated through a heating tube in the tank bottom to keep the tank body at about 100% relative humidity.

A resting (storage) environment
During the static function, the temperature of the cabinet is automatically maintained by the cabinet heater.No spray, drying, air washing, or humidity is produced.

Wet and Dry Combined Salt Spray Tester Salt Spray Corrosion Test Chamber Salt Fog ChamberWet and Dry Combined Salt Spray Tester Salt Spray Corrosion Test Chamber Salt Fog ChamberWet and Dry Combined Salt Spray Tester Salt Spray Corrosion Test Chamber Salt Fog ChamberWet and Dry Combined Salt Spray Tester Salt Spray Corrosion Test Chamber Salt Fog ChamberWet and Dry Combined Salt Spray Tester Salt Spray Corrosion Test Chamber Salt Fog Chamber
Wet and Dry Combined Salt Spray Tester Salt Spray Corrosion Test Chamber Salt Fog Chamber

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier