BGD 867 is a standard xenon chamber which has many functions. It is equipped with three xenon lamps imported from America and daylight filter, can meet with all standards' requirements.
BGD 867 can hold 25 pieces samples, not only has spray function, but also can control the relative humidity of working room.
Operator can set all required test parameters (Irradiance, test time, BPT etc)through the touch screen, and can check its running status at any time. All running parameters can be exported to computer through the USB interface.
BGD 867 Cabinet Xenon Climatic Test Chamber Xenon Lamp Weathering Aging Tester ISO12040
Characters
1. Three xenon lamps imported from America can offer higer irradiance energy, meet with all test strandards' requirements.
2. Can set and control automatically the relative humidity of working room.
3. The test procedures can be programmed freely; and up to 6 predetermined procedures can be saved in one time. Every procedure includes up to 10 segments setting data.
4. Can set the cumulative energy (total irradiance energy) obtained by sample to finish a test procedure.
5. With spray function, can set spray time and spray interval time.
6. Irradiance energy can be accurately controlled. The "Closed-Loop" control system can automatically compensate the change of light intensity caused by ageing or other factors.
7. Users can easily calibrate and adjust the irradiance or the black panel temperature by themselves.
8. With high precision Pt100 temperature sensor. Black panel temperature is auto-controlled during the whole process.
9. Alarm function for protection: Over temperature, big error for irradiance, auto shut-down protection when opening door.
10. Touch screen and user-friendly operation interface allow operator to set the test parameters and monitor all the test process easily.
11. Specimen mounting and evaluation is fast and easy with unique slide-out specimen tray.
12. Real-time data can be collected and recorded. The incidental USB connector allows users to copy the test data into a USB drive, achieving unattended operation.
BGD 867 Cabinet Xenon Climatic Test Chamber Xenon Lamp Weathering Aging Tester ISO12040
Test Standards
ISO 12040 Graphic Technology - Prints and Printing Inks - Assessment of Light Fastness Using Filtered Xenon Arc Light
ISO 16474-2 Paints and varnishes -- Methods of exposure to laboratory light sources -- Part 2: Xenon-arc lamps
ASTM D3451 Standard Guide for Testing Coating Powders and Powder Coatings
ASTM D4303 Standard Test Methods for Lightfastness of Pigments Used in Artists' Paints
ASTM D6577 Standard Guide for Testing Industrial Protective Coatings
ASTM D6695 Standard Practice for Xenon-Arc Exposures of Paint and Related Coatings
ASTM G151Standard Practice for Exposing Nonmetallic Materials in Accelerated Test Devices that Use Laboratory Light Sources
ASTM G155Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials
ISO 4892-1 Plastics - Methods of Exposure to Laboratory Light Sources - Part 1: General guidance
ISO 4892-2Plastics - Methods of Exposure to Laboratory Light Sources - Part 2: Xenon-arc lamps
SAE J2412 Accelerated Exposure of Automotive Interior Trim Components Using a Controlled Irradiance Xenon-Arc Apparatus
BGD 867 Cabinet Xenon Climatic Test Chamber Xenon Lamp Weathering Aging Tester ISO12040
Main Technical Parameters
1. Xenon Lamp:Three 1.8 kW xenon lamps(imported from America)
2. Filter:Daylight filter (Also can choose extended UV filter or window glass filter)
3. Lamp Lifetime: Near 1,500 hours
4. Exposure Area:2,800 cm2 (can put 25 standard samples 150mm×70mm)
5. Adjustable Irradiance Range:
0.3~0.75 W/m2 (Single point of control:340nm)
0.5~1.35 W/m2 (Single point of control:420nm)
30 W/m2~90 W/m2 (Full spectrum :from 300~400nm)
6. Controlling Irradiance Point:340nm or 420nm or 300nm~400nm
7. Adjustable Black Panel Temperature Range:RT~100ºC
8. Adjustable Relative Humidity of Working Room:10%~75%(Light);10%~95%(Dark);
9. Interior Material of Chamber:Aluminium profiles
10. Exterior Material of Chamber:Powder coating
11. Overall Size(W×D×H):950mm×1200mm×2000mm
12. Net Weight:385 kg
13. Power Supply:Three-phase AC 380V,50 or 60Hz;Max. Current: 16A; Rated Power: 7.5kW
14. Requirements of Compressed air:Clean,oilless compressed air with 0.5MPa pressure,Max. air supply is near 60L/min. Average air consumption is 10L/min~30L/min(Depends on testing standard)
15. Ordering Information:
BGD 867---Cabinet Xenon Test Chamber
BGD 8156---American Xenon Lamps (1.8 kW)
BGD 8183---Daylight Filter
BGD 8184---Window Glass Filter
BGD 8185---Extended UV Filter
BGD 8170---Pure Water Machine(50L/h)
BGD 8140/S---Multifunctional Irradiance Radiometer for Xenon lamps(340nm)
BGD 8141/S---Multifunctional Irradiance Radiometer for Xenon lamps(420nm)
BGD 8142/S---Multifunctional Irradiance Radiometer for Xenon lamps(300nm~400nm)
(See Xenon Calibration Radiometer)
BGD 867 Cabinet Xenon Climatic Test Chamber Xenon Lamp Weathering Aging Tester ISO12040
Accessories
BGD 8156---American Xenon Lamps (1.8 kW)
BGD 8183---Daylight Filter
BGD 8184---Window Glass Filter
BGD 8185---Extended UV Filter
BGD 8170---Pure Water Machine(50L/h)
BGD 8140/S---Multifunctional Irradiance Radiometer for Xenon lamps(340nm)
BGD 8141/S---Multifunctional Irradiance Radiometer for Xenon lamps(420nm)
BGD 8142/S---Multifunctional Irradiance Radiometer for Xenon lamps(300nm~400nm)
(See Xenon Calibration Radiometer)