• AA2610 Atomic Absorption Spectrometer Device for Metal Analysis Graphite Furnace Spectrometer
  • AA2610 Atomic Absorption Spectrometer Device for Metal Analysis Graphite Furnace Spectrometer
  • AA2610 Atomic Absorption Spectrometer Device for Metal Analysis Graphite Furnace Spectrometer
  • AA2610 Atomic Absorption Spectrometer Device for Metal Analysis Graphite Furnace Spectrometer
  • AA2610 Atomic Absorption Spectrometer Device for Metal Analysis Graphite Furnace Spectrometer
  • AA2610 Atomic Absorption Spectrometer Device for Metal Analysis Graphite Furnace Spectrometer

AA2610 Atomic Absorption Spectrometer Device for Metal Analysis Graphite Furnace Spectrometer

After-sales Service: Online
Application: Laboratory Apparatus
Warranty: 1 Year
Detection Method: Spectrophotometer
Advantage: High Sensitive
Customized: Customized
Samples:
US$ 3000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
AA2610
Precision
Rsds ≤0.8%
Detection Limit
0.006μg/Ml
Absorbance
>0.300ABS
Burner
100mm Metal Titanium Burner
Transport Package
Plywood Cases
Specification
40*30*18CM
Trademark
LONROY
Origin
Guangdong
HS Code
9024800000
Production Capacity
200

Product Description

AA2610 Atomic Absorption Spectrometer Device for Metal Analysis Graphite Furnace Spectrometer
Performance index
1.Optical system
Wavelength range 190nm -- 900nm
Monochromator anti-aberration C-T monochromator
Spectrum bandwidth 0.2, 0.4, 1.0, 2.0nm, four automatic selectable
Wavelength accuracy ±0.30nm
Wavelength repeatability 0.20nm
Baseline drift static ±0.002A/30min Dynamic ±0.003A/30min
Detector photomultiplier tube
When the resolution is 0.2nm spectral bandwidth, the half-width of the measured spectral line does not exceed 0.2nm±0.02nm

2. Atomization system
Sensitivity (Cu) Mass concentration 2.0ug/ml absorbance greater than 0.300Abs
Detection limit (Cu) 0.006μg/ml
Burner 100mm metal titanium burner, air cooled premixed type
Precision RSD≤0.8%
Sprayer Efficient glass atomizer
Atomization chamber Corrosion-resistant material atomization chamber
Position adjustment Flame burner suitable height and front and rear position can be adjusted, one minute to complete flame/hydride replacement
Safety measures with a variety of automatic safety protection functions, acetylene leakage warning, closing system

3. Analytical method
Measuring method Air-acetylene flame method, hydride generator atomic absorption method, oxygen-enriched air-acetylene flame method
Concentration calculation method Standard curve method (1-3 curve), automatic fitting, standard addition method
Repeated measurement times 1~20 times, calculate the average, give the standard deviation and relative standard deviation
Result printing parameter printing, data result printing, graphic printing, summary report
Software environment Windows 98/2000/XP

Instrument parameter
1. Host machine
Power supply AC 220V/50HZ
Power 150VA
Weight 70kg
Volume 1000mm(L)×350mm(W)×390mm(H)
Working environment temperature 10~35ºC
Working humidity ≤80%

Standard configuration
1. Host
2. Low noise oil free air compressor
3. Operate the software
4. Come with accessories
5. Installation and commissioning
6. Customer on-site training methods
7. Packing and transportation in wooden cases
Special note: To use this model, you should purchase a local PC, if you need to print experimental data, you should also purchase a printer. If it is not convenient to buy a personal computer or printer, we can also buy it on behalf of our company.

Four. Optional accessories
1. Hydride generator
2. Quartz concentrator
3. Oxygen enrichment device

 
AA2610 Atomic Absorption Spectrometer Device for Metal Analysis Graphite Furnace SpectrometerAA2610 Atomic Absorption Spectrometer Device for Metal Analysis Graphite Furnace Spectrometer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now