Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 1 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Summary of the equipment:
LR-A018 type no rotor rheometer is used to control the quality of rubber, rubber processing industry rapidly test and rubber basic research, the most widely used instrument for rubber optimization combination formula provides accurate data, can be precisely measured scorch time, positive rheometer time, sulfide, index and parameters such as maximum and minimum torque.
The main features
1,The non-rotor rheometer adopts the latest version of the latest domestic software, which has the characteristics of fast heating (within 3 minutes) and high temperature control..
2,The non - rotor rheometer adopts alpha - sealed cavity structure and is in the international leading position.
3,The non - rotor vulcanizer adopts advanced alpha force sensor technology.:(Sensor accuracy 0.001N.m)
4,No rotor rheometer using advanced alpha type sealed cavity structure, by importing seal rotating cavity and fixed sealed cavity, and closed type cavity and the general structure of the open cavity is not the same, its precision and requirements and advanced nature is not matching.Airtight mold cavity repeatability completely consistent, in the international leading position.
Working principle:
Put rubber sample in almost completely sealed cavity, and maintain under the test temperature, the cavity has a fluctuation two parts, one part under with tiny linear reciprocating movement (swing oscillation), oscillation samples can produce shear strain, the determination of sample of cavity reaction torque (power), the torque (power) depends on the size of the shear modulus of the rubber.
Sulfide increases the shear modulus of samples after the trial begins, computer machine real-time display and record torque (power), when the torque (power) up to a maximum stable value or even return status, then get a torque (power) and the relation curve of time, namely, vulcanization curve (as shown in figure 1), the shape of the curve and test the temperature and the properties of the rubber.
Application industry:
It is the most important testing instrument for the development of new products, the research of the formulation of rubber materials, the control of the quality of rubber materials and the application of rubber basic research.It is widely used in all kinds of rubber products.
Test standard:
The non-rotor vulcanization test instrument conforms to GB/T16584 rubber -- determination of vulcanization characteristics by non-rotor vulcanization instrument, ISO6502 requirements and the Italian standard requirements of T10, T30, T50, T60, T90 data.
Details of the image:
Technical specification:
Model | LR-A018 |
Temperature range control | RT-200ºC |
Temperature fluctuation range | ±0.15ºC |
Torque resolution | 1/500000 |
Torque accuracy | 0.3% |
Torque unit | N.m,N.cm,N.inch,kN.m,kN.cm,kN.inch,kg.m,kg.cm,kg.inch,lp.m,lp.cm,lp.inch,g.m,g.cm,g.inch |
Temperature display resolution | 0.01ºC |
Temperature recovery time after mold closing | < 1.5min |
Temperature unit | C(degree centigrade ),F(Fahrenheit),K(Kelvin) |
Sampling rate | 200times/S |
Support language | English, simplified Chinese, traditional Chinese |
Test standard | GB/T 16584,ASTM D5289,ISO 6502 |
calculating parameter | ts1,ts2,t10,t30,t50,t70,t90,Vc1,Vc2 |
Software connector | USB2.0 |
Print date | Date, time, temperature, cure curve, temperature curve ,ML,MH,ts1,ts2,t10,t50,t90,Vc1,Vc2 |
test standard | ASTM D 5289, ISO6502 |
oscillation frequency | 100 cycles per minute(1.67Hz) |
amplitude of oscillation | standard configuration: ±1degree ±0.03degree |
optional±0.5degree±0.03degree, ±3degree±0.03degree | |
Variable temperature time | 170ºC→190ºC within 55s ±0.3ºC 190ºC→170ºC with 1minute 40s ±0.3ºC |
Temperature return time after membrane closure |
temperature compensation is restored to the set temperature of 170ºC(error±0.3ºC)not big than 30±3s |
Heating speed | RT→170ºC 2minutes 40s ±0.3ºC |
Power Air source |
220VAC±10%, 50±3Hz; Min minimum 65psi (4.5kg/cm2) |
Size | L65cm x W59cmx H148cm |
Weight | Gross: 300kg , Net: 250kg |