FCAO-2 Free Calcium Oxide Tester/Measurement Cement Dissociative Calcium Oxide Quick Test Meter
Feature
The content of fCaO was determined by electrical conductivity analysis method in automatic calcium oxide tester, which reduced the error of artificial titration and improved the accuracy of measurement. The process of measuring FCaO content is automatically completed in a few minutes, and the test results are automatically displayed, automatically printed, reported to the police, etc. Greatly shorten the measurement time, reduce the labor intensity, showing the obvious advantage of fast and convenient, has played an effective role in the production quality control.
FCAO-2 Free Calcium Oxide Tester/Measurement Cement Dissociative Calcium Oxide Quick Test Meter
Technical parameters:
1.Power supply: 220V±10 50HZ
2.Motor: no ji speed regulation
3.Power: 500W
4.Working environment temperature: 5-40ºC
5.Working environment relative humidity: 50-85 Time: 1-99 minutes (default: 5 minutes)
6.Adjust temperature: 0-99ºC (default: 80ºC)
7.Temperature error: ±1ºC
8.Conductivity type: DJS-1 platinum black electric ji
9.Electric ji constant: The constant is 1, and the electric ji is marked in the range of 0.9-1.1 in the range of constant 1
10.Measurement range: fCaO within 4.0, but above 3.0 according to the national standard has exceeded.
11.Mass: 5KG.
12.Electrical conductivity: 0-2000μs/cm
13.Conductivity resolution: 1μs/cm
14.Accuracy: 1μs/cm
15.Average heating rate: 5ºC/min