Customization: | Available |
---|---|
After-sales Service: | Online |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 3000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
KGBD808 Battery Capacity Discharge Tester Battery Cell Capacity Testing Machine Discharge Analyzer Checker
Product Introduction
KGBD808 battery discharge tester is designed for deep discharge, capacity test and daily maintenance of 48V or 110V or 220V battery sets. Power consumption components all adopt the new PTC, small size, light weight, easy to move. The whole machine is controlled by microprocessor, LCD display, Chinese menu. The discharge parameters can also be entered by the computer. Once the parameters are set, the whole discharge process is automatically completed. Fully intelligent.
KGBD808 Battery Capacity Discharge Tester Battery Cell Capacity Testing Machine Discharge Analyzer Checker
Product Parameters
1, load voltage range: DC48V±10% DC110V±10% DC220V±10%
2, set discharge current: 0-100A (continuously adjustable)
3, current adjustment accuracy: 0.1A
4, current measurement accuracy: 1%
5, voltage measurement accuracy: 1%
6, timing time: 0-15 hours
7. Cooling method: forced air cooling
8, ambient temperature: -10ºC-50ºC
9. Ambient humidity: 20%-80%
10, working power supply: AC220V±15%50±5HZ
11, overall size: 430×300×940 (mm) (length × width × height)
12. Weight: 40Kg
KGBD808 Battery Capacity Discharge Tester Battery Cell Capacity Testing Machine Discharge Analyzer Checker
Product Characteristics
1, microcomputer control, LCD display, Chinese menu; Real-time display of various detection data (voltage, current, discharge start time is timely and long, capacity, voltage protection low limits, etc.) to understand the operating status of the equipment at any time.
2, keyboard operation. Set various discharge parameters and various instructions for machine operation through the keyboard (can also be transmitted through the computer).
3, automatic protection. When the discharge time or discharge capacity is set, the battery voltage is lower than the set protection voltage or the load connection is abnormal, the discharge will stop automatically and the alarm will be generated. At the same time, the shutdown mode is automatically recorded.
4. Power off function. During the discharge process, if there is an unexpected power failure, the preset discharge parameters are automatically saved. After an incoming call, the discharge data is automatically stored continuously, and the device is not damaged.
5. Data collection. Data is collected and stored at a faster rate two minutes after the discharge begins, and every minute thereafter. It is convenient to analyze the performance of battery pack.
6. Data processing. All kinds of detected data can be uploaded to the computer through 232 communication port or USB port, processed by special software (random configuration), generate a variety of intuitive reflection of battery pack performance curves, columns, reports, etc., and can be amplified, queried, printed.
7. Correction function. The voltage and current values can be corrected (verified) either before or during discharge.
8. Data storage. Can automatically store each discharge does not exceed 15 hours eight consecutive discharge data, power failure is not lost.
9, power consumption components. The use of new PTC, safe and pollution-free, small size, light weight, fast heat dissipation.