• Ahs-50 Automatic Headspace Sampling Device Tester for Test The Volatile Component of The Sample
  • Ahs-50 Automatic Headspace Sampling Device Tester for Test The Volatile Component of The Sample
  • Ahs-50 Automatic Headspace Sampling Device Tester for Test The Volatile Component of The Sample
  • Ahs-50 Automatic Headspace Sampling Device Tester for Test The Volatile Component of The Sample
  • Ahs-50 Automatic Headspace Sampling Device Tester for Test The Volatile Component of The Sample
  • Ahs-50 Automatic Headspace Sampling Device Tester for Test The Volatile Component of The Sample

Ahs-50 Automatic Headspace Sampling Device Tester for Test The Volatile Component of The Sample

After-sales Service: Online
Warranty: 1 Year
Type: Headspace Sampler
Maxcapacity: <1000KN
Accuracy Grade: 1
Load Way: Electronic Load
Samples:
US$ 3000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
AHS-50
Display
Digital
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Controllable Number of Foreign Affairs
15
Foreign Affairs Time Control Range
0.1 ~ 99 Minutes
Cylinder Driving Gas Pressure
< 0.4MPa
Heating Station
4
Transport Package
Plywood Cases
Specification
58*57*66cm
Trademark
LONROY
Origin
Dongguan
HS Code
9024800000
Production Capacity
200

Product Description

AHS-50 Automatic Headspace Sampling Device Tester for Test the Volatile Component of the Sample
principle
The simple principle of AHS-50 automatic headspace sampling device is that the sample to be tested is placed in a closed container, and the volatile components of the sample to be tested are volatilized from the sample matrix by heating up to achieve a balance in the gas-liquid (or gas-solid) phase, and the upper gas is directly extracted for chromatography. Thus, the composition and content of volatile components in the sample were detected.
 
1. The rotary valve switching multi-dimensional gas path sampling system overcomes the disadvantages of domestic six-way and 10-way valves, such as short service life and inability to withstand high temperature
2. The gas path process design is very simple, reliable, conducive to leakage prevention, greatly improve the work efficiency
3. Inert treatment technology is adopted in the gas path and sample valve that the sample passes through
4. Optional gas path (EPC electronic pressure control), digital display is more intuitive. It can realize automatic gas path system leak detection and obstacle alarm
5. By adjusting the injection time, the sample has been analyzed for different concentrations
6. For various standards, can store 10 methods
7. Full color screen display, friendly interface, touch operation, can be quickly and easily mastered, the whole tracking display operation process, set parameter value and real time value
8.4 pre-heating stations can realize circulating heating and improve analysis efficiency
9. Expand the scope of services: (1)To provide customers with experimental equipment solutions, technical consultation or co-construction and sharing of chromatographic analysis sample pretreatment related projects
(2)Headspace sampler/functional module/unit assembly and related parts and accessories can be: buy, rent or trade-in
 
 
AHS-50 Automatic Headspace Sampling Device Tester for Test the Volatile Component of the Sample
Characteristic
The main samples suitable for headspace sampling are: liquid, solid and mixture, such as drinking water, wastewater, food testing, pharmaceutical, blood, soil, water, mud, cosmetics, soap, packaging, metal foil,
 
Volatile organic compounds found in paper, mineral mud, spices, etc. Currently, it is mainly used in the following fields:
1. Petrochemical industry: determination of volatile organic compounds in polymer monomer coatings, etc
2. Environmental sciences: Determination of volatile halocarbons in drinking water and organic toxic volatiles in industrial wastewater
3. Hygiene and epidemic prevention: analysis of residual fumigation and disinfection of medical supplies
4. Food industry: quality control of wine, vinegar and soy sauce, analysis of acetaldehyde residues in packaging materials and 6# solvent residues in leached oil
5. Flavor: aroma analysis in beer and tea
6. Quality control of drugs: analysis of organic residual solvents in drugs
7. Forensic chemistry: Determination of ethanol, ketones and aldehydes in blood and urine
8. Others, such as: determination of volatile organic compounds in soil, etc
 
 
AHS-50 Automatic Headspace Sampling Device Tester for Test the Volatile Component of the Sample
Parameters

1. Sample temperature adjustment range: room temperature ~ 380ºC, accuracy ±0.5ºC increment 1ºC
2. Pipeline temperature adjustment range: room temperature ~ 260ºC, accuracy ±0.5ºC increment 1ºC
3. Six-way valve temperature adjustment range: room temperature ~ 260ºC, accuracy ±1ºC increment 1ºC set
4. Controllable number of foreign affairs: 15
5. Foreign affairs time control range: 0.1 ~ 99 minutes timing error: < 0.1 percent
6. Cylinder driving gas pressure: < 0.4MPa (adjustable)
7. Withstand pressure of gas circuit and related components: >0.4MPa
8. Heating station: 4
9. Headspace bottle station: 50
10. Headspace bottle specification: Standard 20ml
11. Repeatability of analysis: RSDS <1% (related to GC performance and operation techniques)
12. Instrument power: < 1000VA
13. Linkage signal output switch time: <2 seconds
14 instrument dimensions: height × width × length :580mm×564mm×666mm
15. Weight: about 40Kg

 
Ahs-50 Automatic Headspace Sampling Device Tester for Test The Volatile Component of The SampleAhs-50 Automatic Headspace Sampling Device Tester for Test The Volatile Component of The Sample

Send your message to this supplier