• Tag-500 Remote Wireless Hv Nuclear Phase Meter Ammeter Current Meter Voltage Detection Instrument
  • Tag-500 Remote Wireless Hv Nuclear Phase Meter Ammeter Current Meter Voltage Detection Instrument
  • Tag-500 Remote Wireless Hv Nuclear Phase Meter Ammeter Current Meter Voltage Detection Instrument
  • Tag-500 Remote Wireless Hv Nuclear Phase Meter Ammeter Current Meter Voltage Detection Instrument
  • Tag-500 Remote Wireless Hv Nuclear Phase Meter Ammeter Current Meter Voltage Detection Instrument
  • Tag-500 Remote Wireless Hv Nuclear Phase Meter Ammeter Current Meter Voltage Detection Instrument

Tag-500 Remote Wireless Hv Nuclear Phase Meter Ammeter Current Meter Voltage Detection Instrument

After-sales Service: Online
Warranty: 1 Year
Type: Hv Nuclear Phase Meter
Maxcapacity: <1000KN
Accuracy Grade: 1
Load Way: Electronic Load
Samples:
US$ 3000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
TAG-500
Display
Digital
Control
Manual Control
Weight
5
Power Source
AC220V
Measured Voltage
10V-500kv
Wireless Transmission Distance
Visual Range 150 Meters
Satellite Timing Range
2-- 30 Minutes
Handset
0.31kg
Transport Package
Plywood Cases
Specification
15*6*4CM
Trademark
LONROY
Origin
Guangdong
HS Code
9024800000
Production Capacity
200

Product Description

TAG-500 Remote Wireless HV Nuclear Phase Meter Ammeter Current Meter Voltage Detection Instrument

Product Introduction

The TAG-500 remote wireless high voltage nuclear phase meter produced by Kekang Power is mainly used in the three-phase electric ultra-long distance nuclear phase of power system, which integrates the functions of long distance nuclear phase, short distance nuclear phase and switch cabinet nuclear. At the same time, it is also suitable for phase verification and phase sequence verification of power lines and substations, including electricity inspection, nuclear phase, phase sequence measurement, etc. This product adopts double shielding and new digital circuit, has strong anti-interference, fully meets the requirements of (EMC) standards, and ADAPTS to various electromagnetic field interference occasions.
TAG-500 remote wireless high voltage nuclear phase meter adopts GPS synchronous measurement technology and wireless transmission technology, reliable high voltage safety isolation, easy operation and stable performance. It is widely used for phase check and phase sequence check of high voltage equipment such as high voltage power lines, substations, power plants, etc. It is an ideal product for nuclear phase test site. In the power system, it is often necessary to do the nuclear phase test in the grid-connected closing, before the new substation is put into operation, the new power plant is connected to the grid, the transmission and transformation project is expanded, reformed or the main equipment is overhauled and the completion of the operation site, especially the long-distance ultra-high voltage transmission line.
The high-voltage phase signal of the measured wire is directly transmitted after processing, and the phase is received by the handheld computer and compared. The result after the nuclear phase is qualitatively determined, and the phase Angle difference and vector diagram are displayed in real time. The phase Angle difference can be measured at a very long distance, so as to achieve a very far nuclear phase, and the machine can continue to work for 30 minutes without a satellite clock. Truly safe, reliable, fast and accurate, different voltage levels (10V-500KV) are applicable. When checking the structure of the power grid, the relative phase of different wires can be accurately identified for three-phase connected lines, and there is no electrical connection between the two measurement components, which makes the application of the measurement device very flexible and safe.

 

TAG-500 Remote Wireless HV Nuclear Phase Meter Ammeter Current Meter Voltage Detection Instrument

Product Characteristics
1, measured voltage: 10V-500KV, different voltage levels are applicable
2, accuracy: short distance nuclear phase: error ≤±3° Long distance nuclear phase: error ≤±3°
3, sampling rate: 10 times/second
4, date and time Settings: adjust the date and time to facilitate users to browse and view historical data
5, backlight time setting: steady on, off, 0-999 seconds can be set by itself
6, automatic shutdown Settings: never, 0-999 minutes can be set by itself
7, in-phase qualitative: ≤20° is in phase (phase threshold 0-90° can be set by itself. System default 20°)
8, out-of-phase qualitative: > 20° for out-of-phase (phase threshold 0-90° can be set by itself. System default 20°)
9, field calibration function: the measured wire can be calibrated on site to ensure the accuracy of phase Angle
10, multi-mode design, more suitable, safer and more convenient
11, unique human-computer interaction interface, simple operation
12, FCC antenna design, the signal is stronger, easier to penetrate the barrier of walls, doors or obstacles
13, double shielding, strong anti-interference, fully in line with EMC standards
14, chart and data display, more convenient and easy to read, with date and time display function.
15, qualitative measurement: through the sound and light signal display
16, quantitative measurement: real-time display of phase Angle difference, error ≤5°
17, phase sequence check: phase sequence, reverse phase sequence (120°, 240°)
18. GPS satellite timing remote nuclear phase distance between X and Y hosts ≥500km.
19, with switch cabinet nuclear phase function.
20. Data storage capacity

 

TAG-500 Remote Wireless HV Nuclear Phase Meter Ammeter Current Meter Voltage Detection Instrument

Product Parameters

Measured voltage

10V-500kV

power supply

Handheld: Large capacity lithium battery

Xa and Ya detectors: No. 7 AA alkaline battery 2 batteries (1.5V)

Wireless transmission distance                     

Visual range 150 meters

same-phas

Phase Angle offset ≤20° (threshold 0-90°, can be set by yourself)

out-phase

Phase Angle offset > 20° (threshold 0-90°, can be set by yourself)                               

Display accuracy

Quantitative measurement ≤5°

Phase Angle resolution

Phase sequence measurement

The indicating phase sequence is determined by 120° clockwise /240° counterclockwise

Satellite timing range

2-- 30 minutes

display

Positive LCD display, can be clearly displayed in sunlight

operating temperature

-35ºC---+50ºC

storage temperature

-40ºC---+55ºC

relative humidity

≤95%RH Non-condensate

handset

0.31kg

X detector

0.16 kg

Y detector

0.16 kg