• Variable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage Generator
  • Variable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage Generator
  • Variable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage Generator
  • Variable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage Generator
  • Variable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage Generator
  • Variable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage Generator

Variable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage Generator

After-sales Service: Online
Warranty: 1 Year
Type: Impulse Voltage Generator
Control: Computer Control
Weight: 0-100Kg
Power Source: AC220V
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
KDCJ-200kV10kJ
Transport Package
Plywood Case
Trademark
LONROY
Origin
China
HS Code
9024800000
Production Capacity
200pieces/Month

Product Description

Variable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage Generator

Product Overview

KDCJ-200kV10kJ lightning impulse voltage generator is suitable for 10KV and below air gap, reactor switch, insulator string, casing, power transformer and transformer and other test products for standard lightning impulse voltage full wave test.

Technical features and advantages:
Industrial computer +PLC optical fiber control system, automatic control test. Automatic polarity switching Industrial computer and PLC use multi-mode optical fiber communication The oscilloscope communicates with the computer by USB The whole equipment is equipped with rigid belt grounding or electromagnet grounding system
Test equipment test system technical scheme
 
Variable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage Generator
Conditions of use
Altitude: ≤1000m Ambient temperature: -15ºC ~ +50ºC Relative humidity: ≤ 85% (20ºC) Use environment: indoor Non-conducting dust The ground resistance is 0.5Ω No fire and explosion hazard Seismic capacity: 8 intensity Does not contain corrosive metal and insulating gas present The waveform of the power supply voltage is the actual sine wave, and the waveform distortion rate < 5% Seismic intensity: The basic seismic intensity value is 6 degrees.
 
According to standards GB/T 16927.1-1997 "High voltage test technology Part I general test requirements" GB/T 16927.2-1997 "High voltage test technology Part II Measurement system" YD/T 5098-2001 "Communication Bureau (station) lightning Overvoltage protection Engineering design Code" GB/T 17626.5-1999 "Electromagnetic compatibility test and measurement technology Surge (impact) immunity test" GB311.1-1997 High voltage transmission equipment insulation coordination GB1094.3 Power transformer Part III insulation level and insulation test Digital recorder for high voltage impact test ZB F24 001-90 impact voltage measurement implementation rules GB191 packing and shipping mark GB4208 enclosure protection class GB813-89 impact test oscilloscope and peak meter DL/T 8485-2004 General technical conditions for high voltage test equipments-Part 5 impulse voltage generators DL/T846.1-2003 General technical conditions for high voltage test equipment - Part 1: high voltage divider measurement systems JB/T563-1993 Technical conditions for ordering coupling capacitors and capacitor dividers JB/T8169-1999 Coupling capacitor and capacitor divider All bolts, studs, threads, pipe threads, bolt clamps and nuts shall comply with the standards of the International Organization for Standardization (ISO) and International System of Units (SI).
 
Variable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage Generator
Programme formulation note
This set of equipment is mainly to meet the 10KV transformer switchgear busings and other electrical equipment lightning full wave and impulse current test. The whole set of equipment is basically equipped with charging device, impulse voltage generator body, impulse weakly damped capacitive voltage divider, measuring device, automatic control system. Impulse voltage generator test equipment This technical document is prepared for the lightning impact test of transformer, reactor, switchgear, bushing and other insulating equipment. The complete set of impulse voltage generator test equipment is composed of impulse voltage generator body, 100kV DC charging device, DF-200kV400PF weak damping capacitive voltage divider, computer measurement, touch screen control system, etc.
 
Impulse Voltage Generator
Structural features (including DC charging device)
The main structure of the impulse voltage generator adopts the form of four-column H structure, and two capacitors are parallel external mounted on the steel body bracket composed of a single flange to form a stable structure. The main equipment is 2-level, composed of composite tower structure, all levels are stacked step by step, easy disassembly and maintenance, and the overall structure is stable. All synchronous discharge balls are installed in a closed insulating cylinder, and each ball gap is equipped with a discharge observation window. During the operation of the equipment, filtered clean air is continuously supplied, the ball gap is not easily affected by environmental changes, and the discharge is stable and reliable, forming a closed ignition and discharge system. At the same time, each stage circuit is equipped with parallel discharge gap, all these measures greatly improve the range of synchronous discharge. The main capacitor is a metal casing pulse capacitor with composite film oil immersion insulation, which is small in size and light in weight. The intrinsic inductance of the capacitor is less than 0.2μH. The outlet sleeve of the capacitor bears a vertical tension of 10Kg. The wave adjusting resistor is plate structure, epoxy casting, no induction winding method, and the joints are spring crimping type, which is convenient to change and allow multiple resistors to be used in parallel at the same time. It is convenient and quick to make the generator run in series and parallel with short-circuit rod.
 
Impulse Voltage Generator
Automatic grounding system: Each high voltage end of the capacitor has an automatic grounding device. When the charging is stopped or the emergency stop button is pressed, the automatic grounding system starts, and the main capacitor of the generator is automatically grounded through the discharge resistance. The single-side half-wave rectifier charging mode is used, and the charging voltage is 100kV. Manual and automatic control voltage regulation, continuously adjustable from zero to 100KV, the charging power automatically shuts off at the moment of ignition and discharge, protecting the safety of the charging transformer and voltage regulation system. Rectifier silicon stack, charging transformer, protection resistor and DC resistance voltage divider are all installed on the body to form a charging, rectifying, and body integrated charging device with simple and beautiful appearance.

Variable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage GeneratorVariable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage GeneratorVariable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage GeneratorVariable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage GeneratorVariable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage GeneratorVariable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage GeneratorVariable Lightning Impulse Voltage Generator/Shock Wave Generator/Impulse Voltage Generator

Send your message to this supplier