Kg-703 Transformer Oleic Acid Value Tester Insulation Oil Acidity Number Analyzer

After-sales Service: Online
Warranty: 1 Year
Type: Oleic Acid Value Tester
Maxcapacity: <1000KN
Accuracy Grade: 1
Load Way: Electronic Load
Samples:
US$ 3000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
KG-703
Display
Digital
Control
Manual Control
Weight
4
Power Source
AC220V
Titration Method
Coulometric Titration (Coulomb Analysis)
Display.
5.6-Inch Color Touch Screen (LCD)
Press
Touch Screen + Physical Button
Power Rate
<40W
Transport Package
Plywood Cases
Specification
37*33*25CM
Trademark
LONROY
Origin
Guangdong
HS Code
9024800000
Production Capacity
200

Product Description

KG-703 Transformer Oleic Acid Value Tester Insulation Oil Acidity Number Analyzer

Product Introduction
The Karl-Fischer Coulometric titration method is the most reliable method for the determination of trace moisture in different substances. This model of automatic trace moisture tester successfully applied this method, adopted advanced automatic control circuit, appearance structure is novel, so that the instrument work more reliable, more convenient. Its analysis speed is fast,
Simple operation, high precision, strong automaticity and so on. Widely used in petroleum, chemical, electric power, railway, pesticide, medicine, environmental protection and other departments.
The reaction formula of Karl Fischer's reagent with water is:
I2 + SO2 + 3C5 H5 N + H2O -→ 2C5 H5 N•HI + C5 H5 N•SO3 ......... (1)
C5 H5 N•SO3 + CH3OH -→ C5 H5 N•HSO4CH3 ...............… (2)
The reagent solution used is a mixture of dominant iodine and sulfur dioxide filled with arsenic, methanol, etc. Iodine is formed on the anode by electrolysis, and the iodine produced is, according to Faraday's law, directly proportional to the amount of charge. As follows:
2I¯+ 2e -→ I2 .............................. (3)

It can be seen from equation (1) that the number of moles of iodine participating in the reaction is equal to the number of moles of water. The sample is injected into the electrolyte, the water in the sample participates in the reaction, and the iodine consumption in the reaction process can be reflected through the instrument, and the iodine consumption can be calculated according to the electricity used in the electrolysis of the same amount of iodine, and the measured water component is directly displayed on the liquid crystal display. The instrument adopts electrolytic current automatic control system, the size of the electrolytic current can be automatically controlled according to the content of water in the sample, the maximum can reach 400mA. In the electrolysis process, the water is gradually reduced, and the titration speed is correspondingly reduced until the electrolytic end point control loop is opened. This system guarantees high precision, sensitive valves and high speeds during analysis. In addition, in the measurement process, it is inevitable that some interfering factors will be introduced, such as the intrusion of moisture from the air, so that the titration tank absorbs moisture and generates blank current. However, since the instrument has the function of storing blank current, the number displayed on the display screen is the true water content of the sample being tested.

 

KG-703 Transformer Oleic Acid Value Tester Insulation Oil Acidity Number Analyzer

Product Parameters
Titration method: Coulometric titration (Coulomb analysis)
Display: 5.6-inch color touch screen (LCD)
Electrolytic current control: 0 ~ 400mA automatic control
Measuring range: 1ug ~ 200mg
Spirit valve: 0.1µg H2O
Accuracy: 10µg ~ 1000µg±3µg
Not more than 0.3% above 1mg
Press: touch screen + physical button
Connecting machine: can transfer data with balance and computer
Printer: Micro thermal printer
Power supply: 220V±10%, 50Hz
Power rate: < 40W
Ambient temperature: 5 ~ 40ºC
Ambient humidity: ≤ 85%
Size: 320×280×200
Weight: About 2.5kg

 

KG-703 Transformer Oleic Acid Value Tester Insulation Oil Acidity Number Analyzer

Feature

1) Adopt 32-bit embedded microprocessor as the main control core and embed mini operating system.
2) High constant current detection accuracy, fast measurement speed, stable and reliable.
3) Real-time electrolysis curve to observe the state of the reagent at any time
4) 12 kinds of analysis methods can save 6 common analysis methods to meet customer needs.
5) Full numeric keypad, data can be entered at any time, data calculation is convenient and fast.
6) The host is equipped with automatic discharge and filling function, which greatly improves the working environment. (optional)
7) Records with time are more convenient to find.

Kg-703 Transformer Oleic Acid Value Tester Insulation Oil Acidity Number AnalyzerKg-703 Transformer Oleic Acid Value Tester Insulation Oil Acidity Number Analyzer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now